INSTALLING YOUR POWER PACK: The MFJ-4114 power pack may be stacked
with a companion MFJ transceiver and tuner. Two brackets and 8
screws are included in this package to connect the power pack to the
MFJ transceiver and tuner.
CONTROLS:
1. POWER
AC/BAT Switch: Select AC or NiCds as power source.
2. AC: Red LED indicates when AC is supplied to MFJ-4114. 3.
CHG: Green LED indicates when Charger is on-line.
4. CHARGER Switch: Turns charger ON or OFF when is AC connected.
OPERATION:
1. TO CHARGE NiCds: Insert the molded plug from the MFJ-407-1106 AC
adapter into the header connector on rear of the MFJ-4114 power
pack. Plug the AC adapter into AC mains. The red AC LED on panel
will light. Press POWER switch to AC, and press CHARGE switch to
ON. The green CHG LED on the panel will light.
NOTE: For best battery life, always press CHARGE switch OFF at the
end of the charge period (prevents overcharging NiCd cells).
2. TO OPERATE TRANSCEIVER FROM AC POWER: Connect AC adapter to the
MFJ-4114. Connect your transceiver to the MFJ-4114 power jack
using a patch cord (5.5mm OD, 2.1mm ID). You may also connect
auxiliary equipment to the red and black binding-post power
terminals (Red = +, Blk = Gnd). Press POWER switch to ON.
3. TO OPERATE TRANSCEIVER FROM NiCd PACK: Connect transceiver as
above. Remove AC wall adapter. Press POWER switch to BAT.
IMPORTANT NOTE: If you operate from BAT with the AC adapter
plugged in, the CHG light still functions -- but the charger circuit
is totally disconnected from the pack. When operating on BAT,
unplug the AC adapter to disable the CHG light and prevent
confusion.
CARE AND FEEDING OF NiCds (for deepest cycle and longest life):
1.
Charge NiCds fully prior to first use.
2.
Always
discharge to 11 VDC (or erratic radio operation).
3.
Always
recharge for full 100 mA period specified on cell.
4.
Never
discharge totally (below 10 V).
5.
Avoid
recharging mid-cycle.