1. This appliance is only for use with the type of gas 

indicated on the rating plate. This appliance is not 
convertible for use with other gases.  

2. Do not place propane/LP supply tank(s) inside or 

under  the  fire  ring.  Locate  propane/LP  supply 
tank(s)  at  least  10  feet  away  (propane/LP  units 
only). 

3. If you smell gas 

• shut off gas supply 
• do not try to light any appliance 
•  do  not  touch  any  electrical  switch;  do  not  use 

any phone in your building 

• immediately call your gas supplier from a neigh-

bor’s  phone.  Follow  the  gas  supplier’s  instruc-
tions 

•  if  you  cannot  reach  your  gas  supplier,  call  the 

fire department 

4. To prevent the creation of soot, follow the instruc-

tions in 

Cleaning and Maintenance

, page 14. 

5. Do not run appliance 

•  where  flammable  liquids  or  vapors  are  used  or 

stored 

• under dusty conditions 

6.  Do  not  use  this  appliance  to  cook  food  or  burn 

paper or other objects. 
7. Do not use this appliance if any part has been 
exposed  to  or  under  water.  Immediately  call  a 
qualified  service  technician  to  inspect  the  room 
appliance  and  to  replace  any  part  of  the  control 
system  and  any  gas  control  which  has  been  un-
der water.  
8.  Turn  appliance  off  and  let  cool  before 
servicing,  installing  or  repairing.  Only  a  qualified 
service  person  should  install,  service  or  repair 
appliance. 
9. This appliances must not be connected to any 
external electrical source. 
10.Operating appliance above elevations of 4,500 
feet may cause pilot outage. 
17.To prevent performance problems, do not use 
propane/LP fuel tank of less than 100 lb. capacity 
(propane/LP units only). 
18.Provide adequate clearances around air open-
ings. 

 

 

 

LOCAL CODES

 

Install  and  use  appliance  with  care.  Follow  all  local 
codes. In the absence of local codes, use the latest 
edition  of 

The  National  Fuel  Gas  Code,  ANSI 

Z223.1/NFPA 54

*. 

*Available from: 

American National Standards Institute, Inc. 

1430 Broadway 

New York, NY 10018 

National Fire Protection Association, Inc. 

Batterymarch Park 

Quincy, MA 02269 

 

 

UNPACKING 

1. Remove burner system and other components 
from  box.  Do  not  grasp  by  burner  tubes.  If  it  is 
evident  that  the  burner  is  damaged,  it  must  be 
replaced  prior  to  being  put  into  operation.  Set 
lava rock boxes aside for further instruction. 
2. Remove all protective packaging from pallet of 
blocks for shipment. 
3. Check for any shipping damage. If appliance is 
damaged call 

Masonry Fireplaces Industries, LLC

 

at  1-

800-345-7078

  for  replacement  parts  before 

returning to dealer. 

www.mason-lite.com 

 

Содержание MASON-LITE MFR16-48

Страница 1: ...OWNER S OPERATION AND INSTALLATION MANUAL FIRE RING MODELS MFR16 48 AND MFR24 48 NATURAL GAS BURNER MODELS MFRBNS 48 PROPANE LP GAS BURNER MODELS MFRBPS 48...

Страница 2: ...rviced Some people are more affected by carbon monox ide than others These include pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high alt...

Страница 3: ...en un der water 8 Turn appliance off and let cool before servicing installing or repairing Only a qualified service person should install service or repair appliance 9 This appliances must not be conn...

Страница 4: ...on Manual Manifold Pressure 6 0 w c Minimum Inlet Supply Pressure 7 0 w c Maximum Inlet Supply Pressure 10 5 w c Orifice 12 MFRBPS 48 Rating 95 000 Btu hr Gas Type Propane LP Gas Only Ignition Manual...

Страница 5: ...ust connect appliance to gas supply Follow all local codes CAUTION Never connect propane LP fire ring directly to the propane LP supply This appliance requires an external regulator not supplied Insta...

Страница 6: ...ent shutoff valve to fire places Apply pipe joint sealant lightly to male NPT threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged appliance val...

Страница 7: ...ints Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect appliance and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1...

Страница 8: ...8...

Страница 9: ...to use only parts specifically approved with this appliance may result in property damage or personal injury 1 Locate a flat even surface to build your fire ring See Specifications page 4 for sizing...

Страница 10: ...layer stagger blocks to the layer below Use 7 full blocks and one half block to build the top layer see Figure 9 After laying out all blocks using a level verify all the blocks are level Shim if neces...

Страница 11: ...s burner system on the top layer of blocks in the pattern shown in Figure 13 9 Connect incoming gas line to regulator shown in Figure 5 page 8 before placing burner system into place 10 Place burner s...

Страница 12: ...12...

Страница 13: ...rocks range in size Begin by placing the smaller rocks between the burner tubes filling the whole pan in a single layer of rocks Avoid placing rocks on the pilot shield They will obstruct the view of...

Страница 14: ...e safety information 2 Make sure equipment shutoff valve is fully open 3 Press in and turn control knob clockwise to the OFF position 4 Wait five 5 minutes to clear out any gas Then smell for gas incl...

Страница 15: ...ing flame an additional 2 to full flame height for a total of three hours INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often PILOT ASSEMBLY The pilot assembly is factory pres...

Страница 16: ...16 BURNER FLAME PATTERN Burner flames will be steady not lifting or floating Flames should go up through middle of the fire ring burner in a tee pee formation Pilot Adjustment Screw Electronic Ignitor...

Страница 17: ...all the blocks are level Shim if necessary 4 When starting the top layer stagger blocks to the layer below Use 8 full blocks After laying out all blocks using a level verify all the blocks are level...

Страница 18: ...including pilot Allow unit to cool for at least thirty minutes 2 Inspect burner pilot and primary air inlet holes on injector holder for dust and dirt see Figure 22 3 Blow air through the ports slots...

Страница 19: ...ace ignitor cable 4 Replace ignitor 5 Replace pilot assembly 6 Replace pilot assembly 7 Install new alkaline battery in electronic ignitor Verify battery is installed correctly When ignitor button is...

Страница 20: ...aning and Maintenance page 14 or replace pilot assembly 5 Hand tighten until snug then tighten 1 4 turn more 6 Replace thermocouple 7 Replace control valve Burner does not light after pilot is lit 1 I...

Страница 21: ...rner is excessively noisy Note The movement and com bustion of gas will create low unavoidable levels of noise 1 Passage of air gas across irregular surfaces 2 Excessive flame impingement or blockage...

Страница 22: ...22 PARTS BURNER MODELS MFRBNS 48 MFRBPS 48...

Страница 23: ...23 PARTS This list contains replaceable parts used in your appliance When ordering parts follow the instructions listed under Replacement Parts on page 21 of this manual...

Страница 24: ...24 PARTS...

Страница 25: ...lly we will ask you to return the part to the factory SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition appliance will not produce specified heat pr...

Страница 26: ...sts incurred for the replacement of defective components MFI is not responsible for misuse or mishandling of the component parts Nothing in this warranty makes MFI or any entity thereof liable in any...