background image

Disclaimer

MFB does not assume any liability for completeness or accuracy for
any of the pages in this manual. We reserve the right to change any
of the terms and contents at any time without advance notice. The
content of this manual has been compiled with meticulous care and
to   our   best   knowledge.   MFB   does   not   take   responsibility   for   any
warranties  for  this  manual   beside   the  ones  being  defined   by  the
corresponding commercial laws.
Any duplication, processing or form of distribution of this manual or
parts of it requires permission of the manufacturer.

Safety Instructions

Please carefully read the following safety instructions! These include
general rules of handling electric products. Carefully read all notes
before operating the unit.

Suitable place of installation

Only use this device in confined spaces, avoid humidity and dust.

Ensure unhindered airflow to all sides of the device. Do not place

the device in direct proximity to heat sources.

Do not expose the device to direct sunlight or strong vibrations.

Electrical connection

Please only use the power supply that comes with the device. It
can be used with a supply voltage of 110 to 240 volts (mains).

If the provided  power supply does not suit  your power socket,
please consult a qualified electrician.

Unplug the power supply if you are not going to use the device
for a longer period.

Never touch the power supply with wet hands.

While unplugging, always pull the plug not the cable!

3

Содержание SYNTH Pro

Страница 1: ...SYNTH PRO Operating Manual 1...

Страница 2: ...IMPRINT MFB Ingenieurb ro Manfred Fricke Neue Stra e 13 14163 Berlin Germany www mfberlin de 2...

Страница 3: ...structions These include general rules of handling electric products Carefully read all notes before operating the unit Suitable place of installation Only use this device in confined spaces avoid hum...

Страница 4: ...solvents or comparable chemicals will damage the device s surface Intended use This device has exclusively been designed to generate and process audio signals as well as control signals corresponding...

Страница 5: ...Filter Output 14 ENVELOPES 15 LFOs 15 VCA 16 EFFECTS 17 MASTER 17 SEQUENCER 18 Sequence Selection and Storing 18 Sequence Input and Playback 18 ARPEGGIATOR 19 Shuffle and Tempo 19 Transpose 20 MIDI SE...

Страница 6: ...on the unit s rear panel Find the POWER ON OFF located alongside Prior to switching on the device connect the AUDIO OUT jack to a mixing console an audio interface or an amplifier Switch SYNTH PRO on...

Страница 7: ...ted by pressing the VALUE encoder consecutively The selected parameter changes in color from red to green and can be adjusted using the VALUE encoder The display shows parameters in six rows 1 the fun...

Страница 8: ...presets easier To save a preset press STORE first In doing so the two LEDs above the button will be lit red green Next press the PRESET button LED lit red select a bank using the VALUE control and a p...

Страница 9: ...honic by the same MIDI channel Rotate the eight voices are addressed by a single MIDI channel but called up one after another Changes of the voice assignment using Type need to be confirmed by pressin...

Страница 10: ...o all oscillators With DCO mode being active the corresponding LED is lit red In this operating mode the oscillators tuning is controlled digitally The pitches are defined exactly which is advantageou...

Страница 11: ...O1 VCO2 Pulse Noise for VCO3 Modulation The modulation sources being selected for pitch and waveform in the VCO menus are adjusted in their intensity using the MOD PITCH and MOD WAVE controls The over...

Страница 12: ...se VCO3 to modulate VCO2 and or VCO1 in frequency To do so press the FM buttons in the sections VCO1 and VCO2 The corresponding LEDs will be lit red By using the FM SELECT button in the VCO3 section i...

Страница 13: ...ifferent sound character Use the PAR SER button to switch the filter routing between serial LED lit red and parallel LED off Each filter has its own set of controls to adjust the CUTOFF filter frequen...

Страница 14: ...25 Green 50 Red Green 100 The assignment of the respective modulation sources and a possible offset for the key follow function is set in MENU VCF1 Setting resp VCF2 Setting Contour Env1 Inv1 Env2 In...

Страница 15: ...speed of the cycle Hint When using a sustain pedal the release times of ENV 1 and ENV 2 will temporarily be set to their maximum values For ENV 3 decay and release are adjusted commonly using the DEC...

Страница 16: ...r an external clock as well as a modulation of LFO 1 by LFO 2 can be set in the MENU LFO Setting LFO1 Sync Gate 1 16 1 8 3 16 1 4 3 8 2 4 3 4 4 4 LFO2 Sync Gate 1 16 1 8 3 16 1 4 3 8 2 4 3 4 4 4 LFO2...

Страница 17: ...ntrol to blend between the pure synthesizer signal and the processed signal The controls VALUE 1 VALUE 2 and VALUE 3 adjust one dedicated parameter of the selected effect each TYPE VALUE 1 VALUE 2 VAL...

Страница 18: ...equently press the SEQUENCE button LED being lit red select a bank using the VALUE control and press a MISC button 1 to 8 The sequence is now stored and the LED above SEQUENCE turns off Hint To avoid...

Страница 19: ...sequence has been completed ARPEGGIATOR The arpeggiator can be used as an alternative to the sequencer By pressing the MISC button ARP 6 SYNTH PRO changes to arpeggiator mode the corresponding LED wi...

Страница 20: ...D will turn off The display setting remains visible until a different MISC function is called up Hint It is recommended to stop the sequencer when changing the shuffle settings because synchronization...

Страница 21: ...ype A use this jack to connect a MIDI keyboard or a MIDI controller with an USB output MIDI IN this jack serves as input for a MIDI keyboard resp MIDI controller with standard MIDI connectors MIDI OUT...

Страница 22: ...O2 Mod Wave 0 127 CC 29 VCO2 Sync 0 64 CC 30 VCO2 Level 0 127 CC 31 VCO2 Wave 0 127 CC 32 VCO3 Mod Pitch 0 127 CC 33 VCO3 Octave 0 32 64 CC 34 VCO3 Interval 0 127 CC 36 VCO3 Mod Wave 0 127 CC 37 VCO3...

Страница 23: ...127 CC 71 VCA Mod 0 127 CC 72 ADSR2 Attack 0 127 CC 73 ADSR2 Loop 0 64 CC 74 ADSR2 Decay 0 127 CC 75 ADSR2 Sustain 0 127 CC 76 ADSR2 Release 0 127 CC 77 Effect Mix 0 127 CC 80 ADSR3 Attack 0 127 CC 8...

Страница 24: ...oduct complies with the following harmonized European standards EN 55013 2003 CENELEC EN 55020 2003 EN61000 3 2 2000 and EN 61000 3 3 1995 correction 1998 This device complies with the EH directive 89...

Отзывы: