11
SECTION VI
MAINTENANCE
MACHINE SHUTDOWN INSTRUCTIONS
1. Close the slide gate. (Turn selector switch CW)
2.
Set the Remote Control Switch to Air to clear the hose of material. When the hose is clear of
material, switch the Remote Control to OFF and disconnect it from the control panel.
3. Turn the Remote On/Off selector switch counter clockwise.
4. Push the throttle all the way in, let it idle for a couple of minutes to cool down.
5.
Turn the engine ignition key to the OFF position. Remove the key.
MACHINE SAFETY SHUTDOWN INSTRUCTIONS
1. Follow the MACHINE SHUTDOWN INSTRUCTIONS.
2.
Disconnect the fuel tank and close the vent on the tank.
3. Disconnect the negative battery terminal and secure it.
4. Follow your employer’s Lockout/Tag out procedures.
NOTE:
Whenever the machine is not in use or is being transported, disconnect the fuel line from the
engine and close the vent on the fuel tank. Secure the tank before transporting the machine.
Before performing any maintenance or service ensure that the machine cannot be
started. Failure to do so could lead to serious injury or death.
The machine must be shutdown properly; the fuel line must be disconnected, the vent on the fuel tank
closed, and the negative battery disconnected and secured according to your employer’s Lockout/Tag
out procedures.
For engine service or maintenance see the engine Operator’s Manual.
Your Meyer Series 1400 Insulation Blowing Machine is designed to be used with minimal maintenance
for all its components. The following is only a guide; experience is the best guide for the right
maintenance schedule for your machine.
ALL BEARINGS
NLGI grade #2 LITHIUM GREASE
DRIVE CHAIN 30W NON DETERGENT MOTOR OIL
BLOWER
OIL: AEON
NLGI grade #2 LITHIUM GREASE
ENGINE
SAE 10W30 MOTOR OIL
REDUCER GEARBOX AGMA #8 GEAR OIL