Meyer Sound Amie-Sub Скачать руководство пользователя страница 9

9

CHAPTER 1: INTRODUCTION

HOW TO USE THIS MANUAL

Make sure to read these instructions in their entirety before 
configuring a Meyer Sound loudspeaker system. In 
particular, pay close attention to material related to safety 
issues.

As you read these instructions, you will encounter the 
following icons for notes, tips, and cautions:

NOTE: 

A note identifies an important or useful 

piece of information relating to the topic under 
discussion.

TIP: 

A tip offers a helpful tip relevant to the 

topic at hand. 

CAUTION: 

A caution gives notice that an 

action may have serious consequences and 
could cause harm to equipment or personnel, 

or could cause delays or other problems.

Information and specifications are subject to change. 
Updates and supplementary information are available at 

www.meyersound.com

.

Meyer Sound Technical Support is available at:

Tel:

 +1 510 486.1166

Tel:

 +1 510 486.0657 (after hours support)

Web:

 

www.meyersound.com/support

THE AMIE-SUB LOUDSPEAKER 

The Amie-Sub was specifically designed to be the perfect 
companion for Amie precision monitors—creating a 
complete system by extending the system frequency 
response down to 22 Hz with easy integration in 
multichannel configurations. 

In addition, due its performance and versatility, the 
Amie

-

Sub is equally suited to complement other Meyer 

Sound loudspeakers, such as HMS-5, HMS-10, HMS-12, 
and HMS-15 (in immersive surround applications) or 
UltraSeries loudspeakers (for more general applications).

Extensive research and measurements resulted in the 
creation of Amie-Sub integration modules to produce 
consistent behavior across multiple configurations and 
environments. These optional integration modules enable 
the Amie-Sub to excel at working in any multichannel 
configuration, creating a perfectly balanced and easy-to-
set-up system with up to seven Amie precision monitors.

The Amie-Sub has an operating frequency range of 
22–160 Hz and a linear peak SPL of 124.5 dB with crest 
factor >11.5 dB (measured in half-space at 4 m and referred 
to 1 m using M-noise). 

The Amie-Sub includes a single 15-inch, low distortion, long 
excursion cone driver. The bass reflex cabinet employs 
optimized port design for high efficiency and low port 
distortion. Its slanted connector panel (Figure 1) facilitates 
flush

-

mounting the cabinet against wall surfaces, reducing 

required installation depth to 19 inches including 
connectors.

!

Figure 1: Amie-Sub Slanted Connector Panel

Содержание Amie-Sub

Страница 1: ...Keep these important operating instructions Check www meyersound com for updates OPERATING INSTRUCTIONS ULTRA Amie Sub Compact Cinema Subwoofer...

Страница 2: ...be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical recording or otherwise without prior writ ten permission from Meyer Sound CAL Compass Go by...

Страница 3: ...the replaceable fuse is the only user serviceable item When replacing the fuse only use the same type and the same value 15 Refer all other servicing to qualified service personnel Servicing is requi...

Страница 4: ...ekter Sonneneinstrahlung fern und stellen Sie es nicht in der N he von w rmeabstrahlenden Ger ten z B Heizger t oder Herd auf Bei Ausstattung mit einem externen Sicherungshalter ist die austauschbare...

Страница 5: ...onerlo a la luz solar directa No instale la unidad cerca de aparatos que emitan calor como un calefactor o una estufa Si est equipado con un portafusibles externo el fusible reemplazable es el nico el...

Страница 6: ...AMIE SUB OPERATING INSTRUCTIONS vi...

Страница 7: ...Current Requirements 13 Intelligent AC Power Supply 14 Electrical Safety Guidelines 14 Chapter 3 Amplification and Audio Connectors 17 Optional Integration Input Modules 18 TruPower Limiting 20 Amplif...

Страница 8: ...AMIE SUB OPERATING INSTRUCTIONS viii...

Страница 9: ...quency response down to 22 Hz with easy integration in multichannel configurations In addition due its performance and versatility the Amie Sub is equally suited to complement other Meyer Sound loudsp...

Страница 10: ...e features industry standard multi pin DB 25 and can be used in 5 1 or 7 1 configurations with third party high quality 8 channel DB 25 to XLR cables The integration modules feature bass management pr...

Страница 11: ...damage to the input and output stages of the system s electronic components 120 V AC 3 Phase Wye System Single Line Line Neutral Earth Ground Figure 4 illustrates a basic 120 V AC 3 phase Wye distribu...

Страница 12: ...power cable 15 A Consider the total current draw for all loudspeakers on the circuit including the first loud speaker Table 1 AC Loop Output Gray The gray AC Loop Output connector allows multiple Amie...

Страница 13: ...not cause the loud speaker s amplifier to cycle on and off or cause dam age to the power supply CURRENT REQUIREMENTS Current draw for loudspeakers is dynamic and fluctuates as operating levels change...

Страница 14: ...ation temporarily during low voltage periods Powering on Amie Sub When powering on Amie Sub the following startup events take place over several seconds 1 Audio output is muted 2 Voltage is detected a...

Страница 15: ...the circuit including the first loudspeaker Make sure the AC power cable for the loudspeaker has the appropriate power plug on the other end for the area in which you will operate the loudspeaker In...

Страница 16: ...AMIE SUB OPERATING INSTRUCTIONS 16...

Страница 17: ...dio source The Loop output connector uses the same wiring scheme as the Input connector see Audio Input XLR 3 Pin Female on this page For applications that require multiple Amie Sub connect the Loop o...

Страница 18: ...LFE Bass Management For the LFE output there are three controls on the user panel that affect operation see Figure 13 and Figure 14 LFE switch the user can selectively add 10 dB of gain by setting thi...

Страница 19: ...Ch or 7 1 DB 25 7 Ch Inputs 2 Ch or 7 Ch 2 Ch or 7 Ch Sum Sum Ch 1 Ch 7 10 dB LFE Gain Switch Base Management Bypass Amie Sub Power Amp On Level 6 dB 0 dB Passive Path Loop Out Balanced Receivers Bala...

Страница 20: ...t summation may be boosted or attenuated by the 6 dB LFE Bass Management dial NOTE The option to boost the signal by 10 dB is provided for playback of recorded audio in situations where the LFE channe...

Страница 21: ...ING SYSTEM CAUTION The Amie Sub loudspeaker is convection cooled The amplifier s heat sink provides natural convection cooling from the air flowing near its fins CAUTION The Amie Sub heat sink can rea...

Страница 22: ...AMIE SUB OPERATING INSTRUCTIONS 22...

Страница 23: ...ch mounting hardware to the building s structural components studs or joists and not just to the wall surface Verify that the building s structure and the anchors used for the installation will safely...

Страница 24: ...h 16 mounting points on both sides of the cabinet The kit includes two 3 8 inch screws washers for attaching the MUB Amie Sub to the loudspeaker BLACK CLOTH GRILLE FRAME The optional grille frame with...

Страница 25: ...on of the environment in which they operate including air temperature pressure humidity and the location of prediction surfaces Importing both CAD DXF and Sketchup SKP files containing detailed venue...

Страница 26: ...ludes custom designed settings for each family of speakers as well as to integrate families together For example the Product Integration feature matches the phase characteristics between Meyer speaker...

Страница 27: ...most common input spectrum and to verify there is still headroom over pink noise COVERAGE 360 single unit varies with number of units and configuration TRANSDUCERS Low Frequency One 15 inch cone driv...

Страница 28: ...er cabling must be of sufficient gauge so that under burst current rms conditions cable transmission losses do not cause the loudspeaker s voltage to drop below the specified operating range Maximum I...

Страница 29: ...PPENDIX A AMIE SUB SPECIFICATIONS 29 AMIE SUB LOUDSPEAKER DIMENSIONS Figure 21 Amie Sub Loudspeaker Dimensions 17 50 in 444 5 mm 24 00 in 610 mm 8 52 in 216 mm 19 00 in 483 mm 9 75 in 248 mm M8 thread...

Страница 30: ...AMIE SUB OPERATING INSTRUCTIONS 30...

Страница 31: ......

Страница 32: ...Sound Laboratories Inc 2832 San Pablo Avenue Berkeley CA 94702 www meyersound com T 1 510 486 1166 2020 Meyer Sound Laboratories Inc All rights reserved Amie Sub Operating Instructions PN 05 251 005...

Отзывы: