25
APPENDIX A: ACHERON DESIGNER SPECIFICATIONS
ACOUSTICAL
Operating Frequency Range
37 Hz – 18 kHz
Note:
Recommended maximum operating frequency range. Response depends on loading
conditions and room acoustics.
Frequency Response
38 Hz – 17 kHz ±4 dB
Note:
Measured free field with 1/3 octave frequency resolution at 4 meters.
Phase Response
230 Hz to 17 kHz ±30°
Maximum Peak SPL
130 dB
Note:
Measured free field with music referred to 1 meter.
Dynamic Range
>110 dB
Coverage
80° horizontal by 50° vertical
Crossover
680 Hz
Note:
At this frequency, both transducers produce equal sound pressure levels.
TRANSDUCERS
Low Frequency
One 12” cone driver
Nominal impedance: 2
Voice coil size: 4”
High Frequency
One 4” compression driver
Nominal impedance: 8
Voice coil size: 4”
Diaphragm size: 4”
Exit size: 1.5”
AUDIO INPUT
Type
Differential, electronically balanced
Maximum Common Mode Range
±5 V DC, clamped to earth for voltage transient protection
Connectors
Female XLR input with male XLR loop output
Input Impedance
10 k
differential between pins 2 and 3
Wiring
Pin 1: Chassis/earth through 1 k
, 1000 pF, 15 V clamp network to provide virtual ground lift at
audio frequencies
Pin 2:
Pin 3: Signal –
Case: Earth ground and chassis
DC Blocking
Differential DC blocking up to the maximum common mode voltage
CMRR
>50 dB, typically 80 dB (50 Hz – 500 Hz)
RF Filter
Common mode: 425 kHz
Differential mode: 142 kHz
TIM Filter
<80 kHz, integral to signal processing
Nominal Input Sensitivity
10 dBV (3.2 V rms, 4.5 V peak) continuous is typically the onset of limiting for noise and music
Input Level
Audio source must be capable of pro20 dBV (10 V rms, 14 V peak) into 600
to pro-
duce the maximum peak SPL over the operating bandwidth of the loudspeaker
AMPLIFIER
Type
Two-channel, Class-D
Содержание Acheron
Страница 6: ...CONTENTS vi ...
Страница 18: ...CHAPTER 4 RIGGING 18 ...
Страница 22: ...CHAPTER 5 RMS REMOTE MONITORING SYSTEM 22 ...
Страница 29: ......
Страница 30: ......
Страница 31: ......