Meyer Sound 600-HP Скачать руководство пользователя страница 37

31

APPENDIX B

APPENDIX B: 600-HP SPECIFICATIONS 

 

ACOUSTICAL

Operating frequency range

36 Hz - 150 Hz  

Note: 

Recommended maximum operating frequency range. Response depends upon 

loading conditions and room acoustics.

Frequency response

39 Hz - 130 Hz ±4 dB

Note:

 Free field, measured with 1/3 octave frequency resolution at 4 meters.

Phase response

46 Hz - 120 Hz ±30°

Maximum peak SPL

138 dB

Note: 

Measured with music, referred to 1 meter, half-space loading.

Dynamic range

>110 dB

Coverage

360° (single unit); varies with number of units and configuration 

TRANSDUCERS

Low frequency

Two 15" cone drivers

Nominal impedance: 4 

Ω

Voice coil size: 4"

Power-handling capability:  1200 W (AES)

Note: 

Power handling is measured under AES standard conditions: transducer driven con-

tinuously for two hours with band limited noise signal having a 6 dB peak-average ratio.

AUDIO INPUT

Type

Differential, electronically balanced

Max. common mode range

±15 V DC, clamped to earth for voltage transient protection

Connectors

Female XLR input with male XLR loop output or VEAM all-in-one (integrates AC, audio & 

network) 

Input impedance

10 k

Ω

 differential between pins 2 and 3

Wiring

Pin 1: Chassis/earth through 220 k

Ω

, 1000 pF, 15 V clamp network to provide virtual 

ground lift at audio frequencies

Pin 2:

Pin 3: Signal -

Case: Earth ground and chassis

DC Blocking

None on input, DC blocked through signal processing

CMRR

>50 dB, typically 80 dB (50 Hz – 500 Hz)

RF filter

Common mode: 425 kHz; Differential mode: 142 kHz

TIM filter

Integral to signal processing (<80 kHz)

Nominal input sensitivity

0 dBV (1 V rms, 1.4 V pk) continuous is typically the onset of limiting for noise and music.

Input level

Audio source must be capable of producing a minimum of +20 dBV (10 V rms, 14 V pk) 

into 600 ohms in order to produce maximum peak SPL over the operating bandwidth of the 

loudspeaker.

AMPLIFIER

Amplifier type

Two-channel complementary power MOSFET output stages (class AB/H)

Output power

2250 W (4500 W peak)

Note: 

Amplifier wattage

 

rating

 based on the maximum unclipped burst sine-wave rms 

voltage that the amplifier will produce for at least 0.5 seconds into the nominal load 

impedance: both channels 67 V rms into 4 ohms. 

Peak power

 based on the maximum 

unclipped peak voltage that the amplifier will produce for at least 100 milliseconds into the 

nominal load impedance: both channels 95 V pk into 4 ohms.

THD, IM TIM

< .02%

Load capacity

Ω

 each channel

Cooling

Forced air cooling, two fans (one ultrahigh-speed reserve fan)

Содержание 600-HP

Страница 1: ...OPERATING INSTRUCTIONS CONCERT SERIES 600 HP Compact High Power Subwoofer Keep these important operating instructions Check www meyersound com for updates...

Страница 2: ...35 C Operating Altitude to 4600 m 15 000 ft Non operating Altitude to 6300 m 25 000 ft Shock 30 g 11 msec half sine on each of 6 sides Vibration 10 Hz to 55 Hz 0 010 m peak to peak excursion 2006 Meye...

Страница 3: ...eci ed by Meyer Sound 12 Use only with the caster rails or rigging speci ed by Meyer Sound or sold with the loudspeaker Handles are for carrying only CAUTION Rigging should only be done by experienced...

Страница 4: ...ges auf ein Minimum zu reduzieren den Lautsprecher vom Stromnetz trennen bevor ggf ein Audio Schnittstellensign alkabel angeschlossen wird Das Netzkabel erst nach Herstellung aller Signalverbindungen...

Страница 5: ...al 13 Understanding the RMS Communication Module s User Panel 13 Service LED Red 13 Service Button 14 Wink LED green 14 Reset Button 14 Activity LED Green 14 User Interface 14 CHAPTER 5 System Integra...

Страница 6: ...ked 23 The MG MICA Multipurpose Grid 24 Flown Con guration 24 Ground Stacked Con guration 25 The Optional MDTL MICA Downtilt Link 25 MCF MICA Caster Frame 25 MDB 600 Dolly Board 27 APPENDIX A Ampli er...

Страница 7: ...ols introduces two comprehensive tools MAPP Online Pro and SIM 3 for assisting you with the acoustical and functional requirements of system design and optimization Chapter 7 QuickFly Rigging discusse...

Страница 8: ...2 INTRODUCTION...

Страница 9: ...essing and driver protection is integrated into a eld replaceable module mounted in the rear of the enclosure The RMS remote monitoring system standard with the rigging version and optional on other c...

Страница 10: ...ications requiring speci c cosmetics Figure 1 5 In transport on MCF MICA caster frame FEATURES BENEFITS Ef cient high power high excursion cone drivers Extremely low distortion for low frequency clari...

Страница 11: ...nnected between Line Line terminals in a 120 V 3 phase Wye system This results in 208 V AC between lines nominal and will therefore draw less current for the same output power compared to operating th...

Страница 12: ...at AC voltage variations from the service entry or peak voltage drops due to long cable runs and or insuf cient gauge cable do not cause the ampli er to cycle on and off CURRENT REQUIREMENTS The 600 H...

Страница 13: ...600 HP subwoofer rear panel with PowerCon connector ground green yellow Y line brown X neutral blue Figure 2 3 NEMA L6 20 power connector pin out neutral blue line brown ground green yellow Figure 2...

Страница 14: ...woofer from a standard three prong Edison outlet since that connector is rated for only 15 amps NEMA 5 15R 125 V AC max CAUTION The 600 HP subwoofer requires a ground connection Always use a grounded...

Страница 15: ...n 1 Pin 2 to Pin 2 and so forth to prevent the polarity from being reversed Any number of loudspeakers with reversed polarity even one in the subwoofer system will result in severe performance degrada...

Страница 16: ...oints frequency and phase response and driver protec tion are determined by the control card installed inside the ampli er CABLING The 600 HP is available with two different cabling con nection option...

Страница 17: ...d conditions and exhibit smooth sonic characteristics we recommend that you do not drive the 600 HP into continuous limiting If an entire system of 600 HPs begins to limit before reaching the required...

Страница 18: ...d for repair information Despite the 600 HP s ltering extensive use or a dusty op erating environment can allow dust to accumulate along the path of the air ow preventing normal cooling To prevent thi...

Страница 19: ...Names assigned during a one time commission Figure 4 1 into the RMS database that resides on your computer as a part of the software Figure 4 1 Commissioning a loudspeaker using RMS This information...

Страница 20: ...t on the acoustical and or electrical activity of the 600 HP itself unless MUTE or SOLO is enabled on the RMS module and from the RMS software USER INTERFACE The RMS software features an intuitive gra...

Страница 21: ...TION The 600 HP s limit LEDs indicate when the safe power level is exceeded If the subwoofers used in the system begin to limit before reaching the required SPL at low frequencies consider adding more...

Страница 22: ...ould be the same if they are coplanar or near each other The 600 HP does not have a polarity reversal switch so make sure that all systems are set to Pin 2 If they are separated by a greater distance...

Страница 23: ...ld be used very carefully to minimize phase shifts that can cause cancellations NOTE When driving the system using the LD 3 with the lters engaged a change of polarity on the Sub Output might be neede...

Страница 24: ...ase shift most commercially available DSP devices have no presets to emulate these parabolic lters CAUTION If the loudspeakers are going to be driven directly from the DSP verify that the outputs of t...

Страница 25: ...APP Online Pro button on www meyersound com After registration and upon approval an email will be sent to you with a user name and password along with the URL where you can download MAPP Online Pro On...

Страница 26: ...3 audio analyzer system includes a selection of hardware options microphones and accessory cables The SIM audio analyzer system is optimized for making audio frequency measurements of an acoustical sy...

Страница 27: ...lication Rigging should be carried out only by experienced professionals CAUTION Always use properly rated rigging hardware CAUTION It is important to inspect rigging hardware regularly and replace wo...

Страница 28: ...coverage from the MICA enclosures lower in the array Table 7 1 600 HP Link Positions to 600 HP own Rear Front Angle for 600 HP below 0 0 0 0 3 3 downtilt 3 0 3 0 0 0 0 0 3 0 Figure 7 4 600 HP at 0 deg...

Страница 29: ...Ground stacked When MICAs are ground stacked above the 600 HP the GuideALinks in MICA allow the same combinations as when a MICA is linked with another MICA but it will create uptilt instead of downti...

Страница 30: ...MICA grid can accommodate a variety of pickup con gurations using its six pick up points three on the front and rear of the frame In addition the grid can be sus pended from a single pickup point with...

Страница 31: ...the bottom MICA and can be used to downtilt MICAs when they are ground stacked on top of the MG MICA or the 600 HP subwoofer Figure 7 10 The MDTL MICA can be used to downtilt MICA loudspeakers when gr...

Страница 32: ...front to back direction of the subwoofers the long side always move the stack sideways to avoid tipping it over Figure 7 13 The 600 HP stack should only be moved sideways when being transported on the...

Страница 33: ...h MG MICA link 2 DO NOT use ground stack holes for flying points SAFETY WARNINGS Figure 7 16 The MG MICA grid can be installed on top of a 600 HP ground stack for transport The MCF MICA also allows 60...

Страница 34: ...MDB 600 includes slots on the sides for this purpose In addition to transport the MDB 600 supports 600 HP subwoofers in a ground stacked con guration CAUTION When using the MDB 600 dolly board to grou...

Страница 35: ...from the cabinet Figure A 3 If the rainhood frame is installed remove the frame from the user panel CAUTION Make sure to disconnect the AC mains from ampli er before removing it from the enclosure Fig...

Страница 36: ...30 APPENDIX A...

Страница 37: ...Wiring Pin 1 Chassis earth through 220 k 1000 pF 15 V clamp network to provide virtual ground lift at audio frequencies Pin 2 Signal Pin 3 Signal Case Earth ground and chassis DC Blocking None on inp...

Страница 38: ...ing range at the speaker Ultimate Short Term Peak Current Draw 39 A pk 115 V AC 20 A pk 230 V AC 45 A pk 100 V AC Inrush Current 7 A pk 115 V AC 7 A pk 230 V AC 10 A pk 100 V AC RMS NETWORK Standard w...

Страница 39: ......

Страница 40: ...2006 Meyer Sound Laboratories Inc 05 149 005 01 A Meyer Sound Laboratories Inc 2832 San Pablo Avenue Berkeley CA 94702 www meyersound com T 1 510 486 1166 F 1 510 486 8356...

Отзывы: