ML-44
MevaLite
Form Walkways
Walkway Bracket
The walkway bracket contains
an integral self-locking pin, and
is mounted to a multi-function
profile (Fig. 44.1).
To mount the bracket:
Rotate it 45°, insert the pin into
the profile hole, then turn it
back to the vertical position. The
bottom of the bracket can then be
secured to the panel with a flange
screw, if required.
After bracket installation the
walkway planking, guard-railing
posts, and guardrails may be
installed. Holes are provided in the
walkway brackets and guardrail
posts for fasteners. The guard-
railing post 100 can accomodate
guardrail sections up to 2 3/8"
thick.
The walkway bracket 90 is capable
of supporting a 25 psf applied
uniform load at a 4:1 factor of
safety against failure when spaced
up to 8' on center (assuming
adequate planking is utilized).
Walkway brackets may only
be occupied when attached to
adequately braced panels (or
panels tied to braced panels) after
guardrails and all other safety
components and anchors are
installed.
Fig. 44.1
Guard-railing post 100
Planking, toprail, midrail and toeboard
components must comply with federal,
state and all applicable local codes and
regulations
Walkway bracket 90
Flange screw 18
Multi-function
profiles
Wall formwork
Technical Instruction Manual / June 2022