MevaLite
ML-27
Stripping Corners
Stacking/Connecting stripping
corners:
To stack corners, make sure that
you have a level surface and both
corners are in the expanded (ready
to pour) position.
Slide the top of one corner under
the mechanism of the other
corner.
Once both mechanisms are
lined up, the corners can be
connected with the connecting
plate and head bolt with cotter pin
(Fig. 27.1).
Then attach the corners to the
intended formwork gang using
the provided formwork locks
(clamps) to keep the corners from
separating.
The ML stripping corner can also
be used for stripping of panels
between corners inside a structure.
In this case, the stripping corner
is used to reduce the compression
between the panels, so they can
easily be removed from the poured
wall between the corners.
Steps:
1. Remove the assembly locks
connecting the stripping corners to
the panels (Fig. 27.2).
2. Activate the ML stripping corner
(Fig. 27.3).
3. Lift the stripping corners off,
then strip the panels (Fig. 27.4).
Fig. 27.2
Fig. 27.3
Fig. 27.4
ML stripping corner has
been activated
Fig. 27.1
Connecting plate with
head bolt and cotter pin
Wall formwork
Technical Instruction Manual / June 2022