6 Technical Data
page 21
ELC N6_N10-V3.1-09/11-GB subject to technical alterations
Type specific data
Type ELC
N6-400-75
ELC
N6-480-75
ELC
N8-400-80
ELC
N8-480-80
ELC
N10-400-80
ELC
N10-480-80
Power factor
typ. 0,95
typ. 0,94
typ. 0,94
typ. 0,94
typ. 0,94
typ. 0,94
Power efficiency
typ. 0,96
typ. 0,95
typ. 0,96
typ. 0,95
typ. 0,96
typ. 0,95
Power supply
3 x 400 V
3 x 480 V
3 x 400 V
3 x 480 V
3 x 400 V
3 x 480 V
Supply current
9,8 A
8,2 A
13,2 A
10,8 A
16,7 A
13,9 A
Max. supply current
10,8 A
9,0 A
14,4 A
11,9 A
18,4 A
15,3 A
Line protection*
16 A
16 A
16 A
16 A
25 A
25 A
Lamp power
6 kW
6 kW
8 kW
8 kW
10 kW
10 kW
Lamp voltage
750 V
750 V
800 V
800 V
800 V
800 V
Tolerance lamp
voltage
± 7 %
± 7 %
± 6 %
± 6 %
± 6 %
± 6 %
*Line protection: 3-channel automatic cut-out characteristic C
Lamp feeder cable: approved types and lengths
The use of cable types which have not been approved by the manufacturer can
lead to malfunction. The possibility of damage to the electronic ballast cannot be
excluded.
Article
no.
Type
ELC
N6-400-75
ELC
N6-480-75
ELC
N8-400-80
ELC
N8-480-80
ELC
N10-400-80
ELC
N10-480-80
8036
Lamp feeder cable
1 kV
3 x 2,5 mm² NR +
PE
Ø 10,5 mm
5-20 m
5-20 m
5-20 m
5-20 m
5-20 m
5-20 m
40017
"Y" form 1 kV / 10 m
Lamp feeder cable,
shielded
Ø 10,5 mm
10 m
8068
Lamp feeder cable
1,6 kV 2x2,5 mm²
Ø 10,5 mm
5-20 m
5-20 m
5-20 m
5-20 m
5-20 m
5-20 m
The data refers to distance between ELC and lamp.