RFC 2544. Parameters Configuration
4.2
Frame
Figure 4.3. The
Frame
Tab Configuration Window
This tab allows to configure the following parameters.
•
Frame size (Bytes)
— size of the data packets used for testing pur-
poses. Standard packets of 64, 128, 256, 512, 1024, 1280, 1518 bytes
can be chosen, and any other value in the range from 64 to 1518 bytes
inclusive, except currently selected.
Note:
at least one value must be chosen.
•
Ethernet
— this tab contains fields to enter source and destination
MAC addresses that will be inserted in the corresponding fields of the
test packets. The
Automatically
tab is used to insert MAC addresses
of source and destination interfaces that are chosen in the
Topology
tab.
MAC addresses may be configured using virtual keyboard. Virtual key-
board (refer to Figure 4.4 ) is displayed on pressing with a stylus to
the MAC address input field, and has symbols (characters and digits)
necessary to enter the MAC address.
Bercut-MMT: Ethernet Networks Analysis
Содержание Bercut-MMT
Страница 1: ...Bercut MMT Ethernet 10 100 and Gigabit Ethernet Analysis Operation Manual 1 2 7 2009 Metrotek ...
Страница 6: ...6 CONTENTS Bercut MMT Ethernet Networks Analysis ...
Страница 12: ...12 General Information Bercut MMT Ethernet Networks Analysis ...
Страница 16: ...16 Staring Up Bercut MMT Ethernet Networks Analysis ...
Страница 52: ...52 IPX Protocol Bercut MMT Ethernet Networks Analysis ...
Страница 56: ...56 SNMP Protocol Bercut MMT Ethernet Networks Analysis ...
Страница 72: ...72 Remote Testing Bercut MMT Ethernet Networks Analysis ...
Страница 82: ...82 Technical support Bercut MMT Ethernet Networks Analysis ...
Страница 84: ...84 Troubleshooting Bercut MMT Ethernet Networks Analysis ...