8.2 Lambda
For some applications it is of importance to know the lambda value of a combustion gas or of
a gas/air mixture. In this case, lambda is defined as follows:
Lambda = (combustion air supplied)/( combustion air theoretically required)
If this feature is required, it is necessary for a characteristic value to be entered in the "Param-
eter" menu.
Note:
Calculation of dew point is a mathematical function. If the C/H value
changes or is not present, then the lambda value can no longer be calculated
correctly
8.3 CO
The CO value is derived from the lambda function. (see note under lambda)
8.4 Calculated oxygen value
The calculated oxygen value "O2B" of a nitrogen/hydrogen mixture is determined from the
hydrogen percentage (see under "Dew point" option)