Ion Technologies MSE50V

Sewage Pump

OPERATION MANUAL

Dated: 03/30/2020

Document Name: MSE50V_OM

Page 5 of 8

www.ionproducts.net

• 

Impeller or volute openings are fully or partially 

clogged. Remove pump and clean.

•  Pump impeller is partially clogged with tar or 

paint,  causing  motor  to  run  slow  and  overload. 

Remove pump and clean.

FUSE BLOWS OR CIRCUIT BREAKER TRIPS 

WHEN PUMP STARTS

•  Pump impeller is partially clogged causing motor 

to  run  slow  and  overload.  Remove  pump  and 

clean.

• 

Motor stator may be defective.

•  Fuse size or circuit breaker may be too small. 

(must be 15 amps).

• 

Impeller  or  volute  opening  are  fully  or  partially 

clogged. Remove pump and clean.

MOTOR RUNS FOR A SHORT TIME, THEN STOPS

• 

Inlet  holes  in  pump  base  are  clogged.  Remove 

pump and clean the openings.

•  Pump impeller is partially clogged causing motor 

to  run  slow  and  overload.  Remove  pump  and 

clean.

• 

Motor stator may be defective.

• 

Impeller or volute openings are fully or partially 

clogged.

• 

Remove pump and clean. Also clean the strainer 

if one is installed.

ELECTRICAL PRECAUTIONS

WARNING:

 Before servicing a pump, always 

shut off the main power breaker and then 

unplug the pump. Make sure you are not standing 

in  water  and  are  wearing  insulated  protective  sole 

shoes, under flooded conditions. Contact your local 

electric  company  or  a  qualified  licensed  electrician 

for  disconnecting  electrical  service  prior  to  pump 

removal. 

 

P

erformance

S

PecificationS

15.91”

13.53”

10.4”

11.53”

2” NPT

15.91”

13.53”

10.4”

11.53”

2” NPT

Head - feet

Capacity - US GPM

0

25

15

5

10

20

30

0

100

80

60

40

20

120

140

Содержание ion Take Control MSE50V

Страница 1: ... National Electric Code and all applicable state and local codes Requirements may vary depending on usage and location WARNING Installation and servicing is to be conducted by qualified personnel only DANGER Rotating machinery Amputation or severe lacerations can result Keep clear of suction and discharge openings DO NOT insert fingers into pump with power connected WARNING Always wear eye protect...

Страница 2: ...safe operation of the product Receiving and Installation Pump Down Test Be sure pump has been plugged in lowered into the basin or sump check the system by filling with liquid and allowing the pump to operate through its pumping cycle The time needed to empty the system or pump down time along with the volume of water should be recorded Thermal Protection The normally closed N C over temperature s...

Страница 3: ...ate for oil expansion Apply pipe thread compound to threads of pipe plug then assemble to motor housing Check that o ring is in place and does not need to be replaced Reassemble cord cap to motor housing DO NOT overfill oil Overfilling of housing withoilcancreateexcessiveanddangerous hydraulic pressure which can destroy the pump and create a hazard Overfilling oil voids warranty Cooling Oil Recomm...

Страница 4: ... ft lbs PUMP DOES NOT RUN AND MAKES HUMMING SOUND Line circuit breaker is off or fuse is blown or loose Water level in sump has not reached turn on level as indicated in installation drawing Pump cord is not making contact in receptacle Float is stuck It should operate freely in basin If all of the above are OK then the motor could be malfunctioning PUMP RUNS BUT DOES NOT DELIVER WATER Check if va...

Страница 5: ...A SHORT TIME THEN STOPS Inlet holes in pump base are clogged Remove pump and clean the openings Pump impeller is partially clogged causing motor to run slow and overload Remove pump and clean Motor stator may be defective Impeller or volute openings are fully or partially clogged Remove pump and clean Also clean the strainer if one is installed ELECTRICAL PRECAUTIONS WARNING Before servicing a pum...

Страница 6: ...Ion Technologies MSE50V Sewage Pump OPERATION MANUAL Dated 03 30 2020 Document Name MSE50V_OM Page 6 of 8 www ionproducts net noteS ...

Страница 7: ...Ion Technologies MSE50V Sewage Pump OPERATION MANUAL Dated 03 30 2020 Document Name MSE50V_OM Page 7 of 8 www ionproducts net noteS ...

Страница 8: ...o actions taken by Metropolitan to correct a defect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unless and until Buyer notifies Metropolitan in writing of the defect and then only if such notification is made prior to the expiration of the period set forth above 3 P...

Отзывы: