Metropolitan Industries ion Take Control MSE50V Скачать руководство пользователя страница 2

Ion Technologies MSE50V

Sewage Pump

OPERATION MANUAL

Dated: 03/30/2020

Document Name: MSE50V_OM

Page 2 of 8

www.ionproducts.net

CAUTION:

 Make sure lifting handles are 

securely fastened each time before lifting.

DANGER: 

Do not lift, carry or hang pump by 

the electrical cables. Damage to the electrical 

cables can cause shock, burns or death. Never handle 

connected power cords with wet hands. Use 

appropriate lifting device. 

WARNING:

 Sump and sewage pumps often 

handle materials which could cause illness or 

disease.  Wear  adequate  protective  clothing  when 

working on a used pump or piping. Never enter a basin 

after it has been used.

DANGER: 

Failure to permanently ground the 

pump, motor and controls before connecting to 

power can cause shock, burns or death.

DANGER: 

These pumps are NOT to be 

installed  in  locations  classified  as  hazardous 

in accordance with the National Electric Code, ANSI/

NFPA 70. 

WARNING:

 Do not introduce into any sewer, waste 

disposal unit or toilet: Seafood Shells, Aquarium 

Gravel, Cat Litter, Plastic Objects, Sanitary Napkins or 

Tampons, Diapers, Rags, Disposable Wipes or Cloth, 

Medications, Flammable Material, Oil or Grease, 

Strong Chemicals, Gasoline.

• 

Operation  against  a  closed  discharge  valve  will 

cause premature bearing and seal failure on any 

pump. 

•  Any wiring of pumps should be performed by a 

qualified electrician. 

• 

Cable  should  be  protected  at  all  times  to  avoid 

punctures, cuts, bruises, and abrasions —inspect 

frequently. 

• 

Never  handle  connected  power  cords  with  wet 

hands. 

• 

Never  let  cords  or  plugs  lie  in  water  outside  the 

sump pit. 

Do not throw away or lose this manual. Keep it in a safe 

place so that you may refer to it often for the continued 

safe operation of the product.

r

eceiving

 

and

 i

nStallation

Pump-Down Test - Be sure pump has been plugged 

in, lowered into the basin or sump, check the system 

by  filling with liquid and allowing the pump to operate   

through its pumping cycle. The time needed to empty 

the system, or pump-down time along with the  volume 

of water, should be recorded.

Thermal Protection

The  normally  closed  (N/C)  over  temperature  sensor 

is  embedded in the motor windings and will detect 

excessive  heat  in  the  event  an  overload  condition 

occurs. The thermal sensor will trip when the windings 

become  too hot and will automatically reset when the 

pump motor cools to a safe temperature. 

In  the  event  of  an  over  temperature,  the  source  of 

this condition should be determined and repaired 

immediately. Thermal protection shall not be used as a 

motor overload device. 

Maintenance

Minimal maintenance is required. Perform the following 

checks when pump is removed from operation or when 

pump performance deteriorates:.

a. 

Inspect  motor  chambers  for  oil  level  and 

contamination.

b. 

Inspect impeller and body for excessive build-up 

or clogging.

c.  Inspect motor and bearings.

d.  Inspect seal for wear or leakage.

Servicing

Cooling Oil

  -  Anytime  the  pump  is  removed  from  

operation, the cooling oil in the motor housing should 

be  checked  visually  for  oil  level  and  contamination. 

To check oil, set unit upright. Remove pipe plug from 

housing. With a flashlight, visually inspect the oil in the 

housing to make sure it is clean and clear, light amber 

in color and free from suspended particles. Milky white 

oil indicates the presence of water. Oil level should be 

just above the motor when pump is in vertical position.

Oil Testing

•  Drain oil into a clean, dry container by placing pump 

on it’s side. Remove pipe plug, from housing.

•  Check oil for contamination using an oil tester with 

a range to 30 Kilovolts breakdown.

Содержание ion Take Control MSE50V

Страница 1: ... National Electric Code and all applicable state and local codes Requirements may vary depending on usage and location WARNING Installation and servicing is to be conducted by qualified personnel only DANGER Rotating machinery Amputation or severe lacerations can result Keep clear of suction and discharge openings DO NOT insert fingers into pump with power connected WARNING Always wear eye protect...

Страница 2: ...safe operation of the product Receiving and Installation Pump Down Test Be sure pump has been plugged in lowered into the basin or sump check the system by filling with liquid and allowing the pump to operate through its pumping cycle The time needed to empty the system or pump down time along with the volume of water should be recorded Thermal Protection The normally closed N C over temperature s...

Страница 3: ...ate for oil expansion Apply pipe thread compound to threads of pipe plug then assemble to motor housing Check that o ring is in place and does not need to be replaced Reassemble cord cap to motor housing DO NOT overfill oil Overfilling of housing withoilcancreateexcessiveanddangerous hydraulic pressure which can destroy the pump and create a hazard Overfilling oil voids warranty Cooling Oil Recomm...

Страница 4: ... ft lbs PUMP DOES NOT RUN AND MAKES HUMMING SOUND Line circuit breaker is off or fuse is blown or loose Water level in sump has not reached turn on level as indicated in installation drawing Pump cord is not making contact in receptacle Float is stuck It should operate freely in basin If all of the above are OK then the motor could be malfunctioning PUMP RUNS BUT DOES NOT DELIVER WATER Check if va...

Страница 5: ...A SHORT TIME THEN STOPS Inlet holes in pump base are clogged Remove pump and clean the openings Pump impeller is partially clogged causing motor to run slow and overload Remove pump and clean Motor stator may be defective Impeller or volute openings are fully or partially clogged Remove pump and clean Also clean the strainer if one is installed ELECTRICAL PRECAUTIONS WARNING Before servicing a pum...

Страница 6: ...Ion Technologies MSE50V Sewage Pump OPERATION MANUAL Dated 03 30 2020 Document Name MSE50V_OM Page 6 of 8 www ionproducts net noteS ...

Страница 7: ...Ion Technologies MSE50V Sewage Pump OPERATION MANUAL Dated 03 30 2020 Document Name MSE50V_OM Page 7 of 8 www ionproducts net noteS ...

Страница 8: ...o actions taken by Metropolitan to correct a defect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unless and until Buyer notifies Metropolitan in writing of the defect and then only if such notification is made prior to the expiration of the period set forth above 3 P...

Отзывы: