SERVICING AND MAINTENANCE PROCEDURES
Horizontal Scan Window Replacement
(Sapphire Window ONLY!)
1. Lift platter straight up to remove.
2. Position the replacement platter in the
support channel and over the alignment
guide. The MS2020 scale unit does not
have a support channel or alignment
guide. The platter simply sits over the
scale arms.
Horizontal Scan Window Replacement
(Diamonex Window ONLY!)
1. Lift platter straight up to remove from
Stratos Chassis.
2. Remove two philips head screws on
window side of the platter, allowing the
steel reinforcement bar to come free.
(Shown in Figure to the right)
3. Carefully remove plastic Metrologic
Logo ‘BREAK’ brace from platter by
pulling straight out, away from the
platter itself. (See Figure to the right)
4. Diamonex glass can now be removed
by carefully push up on glass from
underside of platter, along rear edge
shown in Figure below.
5. Carefully install new glass in the reverse
order as glass was removed. Ensure
that when glass is installed, the ‘THIS
SIDE UP’ message etched into glass is
readable. (See Figure below & to the
right)