background image

4

Scanner Installation

Important Note:

 To maintain compliance with applicable standards, all

circuits connected to the scanner must meet the requirements for SELV (Safety
Extra Low Voltage) according to EN 60950.

1.

"Power off" the host system.

2.

Connect the communication cable to the host device.

3.

Plug the scanner cable to the communication cable.

Note:

 The pin assignments for the scanner cable are listed on

page 29.

4.

"Power on" the host system.

Note:

 When the scanner 

first

 receives power, diagnostic prompts

are displayed then the scanner "beeps." "READY TO
SCAN" appears on the display.

Configuration to the Host System

Before the scanner ships from the factory, the factory programs the scanner  to
a set of default parameters. However, many functions of the scanner can be
modified to meet your individual needs. The scanner’s parameters can be
modified by entering the program mode and scanning the appropriate bar
codes that appear in the Programming Guide. For a list of various parameter
settings, refer to the Default Settings section in this guide. To modify the
settings, refer to the Programming Guide.

Содержание IS4320-41 ScanKey

Страница 1: ...METROLOGIC INSTRUMENTS INC IS4320 41 ScanKey Laser Bar Code Scanner Installation and User s Guide MLPN 2347 Printed in USA October 1998...

Страница 2: ...Brooklin 05 08 Techlink CEP 04571 090 S o Paulo SP Brasil Singapore 417818 Outside Brazil Tel 65 842 7155 Tel 55 11 5505 6568 Fax 65 842 7166 Fax 55 11 5505 1681 ant888 cyberway com sg info sa metrol...

Страница 3: ...ual Indicators 7 Entering Data Using the Keypad 8 Mode Descriptions 9 Command Processing Set for ScanKey Mode 1 3 and 4 10 13 Command Processing Set for ScanKey Mode 2 14 16 Label Locations 17 IR Sens...

Страница 4: ...iv Appendix D Pin Assignments for the Scanner Connector 29 Appendix E Warranty and Disclaimer 30 31 Appendix F Notices 32 33 Appendix G Patents 34 Index 35 36...

Страница 5: ...yed and then transmitted to the host device Portable data terminals and computers requiring RS 232 or Light Pen Emulation communication are common host devices Metrologic s HandSet IBM compatible soft...

Страница 6: ...t to approximately 4 to 7 Long Range Activation The IR signal initiates the scan process if it senses an object anywhere from the face of the window out to approximately 9 to 13 If the object is remov...

Страница 7: ...ton with the purchase of a ScanKey scanner Installation and User s Guide and Programming Guide ScanKey Laser Bar Code Scanner Communication Cable Glove To order additional items contact your dealer di...

Страница 8: ...en the scanner first receives power diagnostic prompts are displayed then the scanner beeps READY TO SCAN appears on the display Configuration to the Host System Before the scanner ships from the fact...

Страница 9: ...and a message indicating scanner status on another When the cursor flashes the laser is on Keypad Used to enter and transmit numeric and alpha characters Alpha characters can be entered by pressing tw...

Страница 10: ...led diagnostics Note The scanner can be programmed to emit a razzberry tone when the timeout occurs during communica tion between the host and scanner Refer to the Programming Guide section Audible In...

Страница 11: ...d ready to scan a bar code PROGRAM MODE Scanning the Enter Exit Program mode bar code ENABLED alternately enables and disables the program mode When the program mode is enabled this message is display...

Страница 12: ...current cursor position and increments the cursor to the next character position The down arrow acts the same as a backspace key on a computer keyboard It places a space in the previous character posi...

Страница 13: ...t is being displayed on line 1 it will be cleared to allow for the 21st and subsequent characters to be displayed The entire length of the bar code will be transmitted up to and including the 40th cha...

Страница 14: ...Command x y z To set activation range STX R x ETX x 4CH for Long 53H for short 02H 52H x 03H To set bar length STX L x y ETX x minimum 01H 20H 2H 4CH x y 03H y maximum 01H 20H To clear entire display...

Страница 15: ...H Enable scan beep 02H 48H x 03H Sound razzberry tone STX Z ETX 02H 5AH 03H Disable Scanning STX D ETX keypad and display 02H 44H 03H still active Note Reserve code 94 must also be enabled Enable Scan...

Страница 16: ...Keys C Clear display line 2 Mode 3 E same as bar code Sends contents of the display buffer to the host U Forward space places a space at the current cursor position and moves the cursor to the next c...

Страница 17: ...sing that key ie 0 9 DECIMAL POINT LEFT RIGHT ENTER LTR FN F2 Selects the alternate or alpha representation of the key ie single letter commands ALT G F3 Use this key for commands where the ALT key is...

Страница 18: ...52H x 7FH To set bar length ESC L x y DEL x minimum 01H 20H 1BH 4CH x y 7FH y maximum 01H 20H To clear entire display ESC C DEL 1BH 43H 7FH To clear individual ESC c x DEL x 31H clear line 1 32H clea...

Страница 19: ...8H x 7FH Sound razzberry tone ESC Z DEL 1BH 5AH 7FH Disable Scanning ESC D DEL keypad and display 1BH 44H 7FH still active Note Reserve code 94 must also be enabled Enable Scanning ESC E DEL 1BH 45H 7...

Страница 20: ...ault Baud 9600 Parity none Label Detection L 4CH An L will be transmitted when in Detect and Notify mode The L is in response to the IR sensor sensing an object in its field This should be used in con...

Страница 21: ...RH Class II laser system A CDRH Class II label will be at the bottom of the unit with the serial number label An Avoid exposure laser light emitted from this aperture label will be on the side of the...

Страница 22: ...tends approximately 9 13 beyond the output window The IR sensor remains active as long as power is applied to the unit When the unit remains dormant for a time the laser will turn off In this stage th...

Страница 23: ...d occasional cleaning 1 Spray glass cleaner onto lint free nonabrasive cleaning cloth 2 Gently wipe the output window Applications and Protocols The model number on each scanner includes the scanner n...

Страница 24: ...Specifications subject to change without notice Electrical Power 75 watts Input Voltage 5VDC 25V Operating Current 160 mA at 5 VDC Standby Current 88 mA at 5 VDC Operational Bar Width Code Density Dep...

Страница 25: ...EF Humidity 5 to 95 relative humidity non condensing Light Levels Up to 3200 foot candles works in direct sunlight Ventilation None required Shock Drop of 1 5 meters 5 ESD 8 kV IEC 801 2 Contaminants...

Страница 26: ...Although the Programming Guide mentions DTR input Poll Light Pen 5 Volts and No Poll Light Pen the IS4320 41 ScanKey scanner cannot support these options Parameter Default RS 232 Light Pen Enter Prog...

Страница 27: ...Suffix T Tab Prefix T Tab Suffix T Prefix ID for UPC EAN T Suffix ID for UPC EAN T Bars High T Spaces High T Transmit as Scanned T Transmit as Code 39 T UPC T T EAN T T Code 39 T T Codabar T T Code 1...

Страница 28: ...Required T Mod 43 Check Digit T T Transmit Mod 43 Check Digit T T Transmit Start Stop T T CLSI Editing Enable T ITF Check Digit T T Transmit MOD 10 ITF Check Digit T T I 2 of 5 Symbol Lengths Variabl...

Страница 29: ...ER EXIT PROGRAM MODE code again If no scanning occurs for 30 seconds while the scanner is in program mode the unit will beep three times and all changes made will be lost If this occurs return to Step...

Страница 30: ...ding with DEL 7FH Disable ScanKey Mode 2 Enable ScanKey Mode 3 When this option is enabled the scanner will transmit ScanKey Mode 3 specific commands beginning with STX 02H and ending with ETX 03H Dis...

Страница 31: ...play Options Enable Display Mode When this option is enabled the scanner will display all data mode dependant Disable Display Mode When this option is disabled no data will be displayed unless sent vi...

Страница 32: ...tion Enable Blinking Display When this option is enabled the entire display will blink Enable Blinking Cursor When this option is disabled the 40th Character Position cursor will blink at the 40th of...

Страница 33: ...canner is equipped with a 9 pin PCMCIA breakaway connector Pin Function 1 5 VDC Power to Scanner 2 Power Signal Ground 3 RS 232 Transmit Output 4 RS 232 Receive Input 5 Request To Send Output 6 Clear...

Страница 34: ...ich in the sole judgement of Metrologic has been subjected to misuse neglect improper installation or accident nor does it extend to any Product which has been repaired or altered by anyone who is not...

Страница 35: ...d haften nicht f r die Richtigkeit im Hinblick auf Inhalt oder Genauigkeit der Angaben dieser Ver ffentlichung oder des hierin beschriebenen Produkts Sie bernehmen ebenso keinerlei Eignungsgarantie od...

Страница 36: ...ard Remarque Apr s contr le de cet appareil on a not qu il r pondait aux valeurs limites de la classe A c onform ment la partie 15 des directives de l administration f d rale am ricaine pour les t l c...

Страница 37: ...en Der Einsatz optischer Ger te mit dieser Laserausr stung erh ht das Risiko einer Sehsch digung N B Dal controllo di questo apparecchio risulta che esso risponde ai valori limite per apparecchi digit...

Страница 38: ...24 924 5 396 053 5 396 055 5 408 081 5 410 139 5 436 440 5 449 891 5 468 949 5 479 000 5 532 469 5 545 889 No license right or sublicense is granted either expressly or by implication estoppel or othe...

Страница 39: ...19 22 Internet ii Compliance 4 Introduction 1 Configuration 4 22 28 IR Sensor 2 11 12 15 Contrast 20 16 18 Copyright ii Current 20 Customer Service ii 30 D Decode capability 20 Default settings 22 24...

Страница 40: ...atents 34 PCMCIA 29 Pin assignments 29 Warranty 30 Print contrast 20 Watt s 20 Programming guide 3 4 6 Weight 20 22 Window 2 5 18 20 25 Protocols 19 22 24 R Repair 31 Rights property 34 warranty 31 RM...

Отзывы: