background image

23

A

PPENDIX 

B (

CONTINUED

)

P

ARAMETER

D

EFAULT

RS-232

RS-422

L

IGHT

P

EN

200 msec to find Supps

9

9

9

Code 128 Coupon Option

9

9

9

Code 128 Coupon Conversion

9

9

9

378/379 lock on supplement

9

9

9

Remote supplement required

9

9

9

MISCELLANEOUS

Beep after transmitting

9

9

9

Beep before transmitting

*

9

9

9

Faster Beep/Same Tone

9

9

9

Lost Communication Timeout 3 beeps on timeout
razz beep on timeout 5 retrys before timeout

9

9

9

Support 'D/E' disable/enable commands

9

9

Support 'F/L' laser off/on commands

9

9

Enable MECCA

9

9

9

One Compare Buffer

*

9

9

9

Two Compare Buffers

9

9

9

Four Compare Buffers

9

9

9

Eight Compare Buffers

9

9

9

Scan Count

9

9

9

Reverse LED convention

9

9

9

Support multiple beep 'B'/razz 'Z' commands

9

9

Support host BEL/CAN (cancel) command

9

9

Enter program mode only after power up

9

9

9

Enable status reporting

9

9

Number of good scans required (1-8)

1

9

9

9

Special code select

9

9

9

Normal volume

*

9

9

9

Loud Volume

9

9

9

Support 'M/O' motor off/on commands

9

9

TRIAC/LINE SENSOR

Support Line Sensor

9

9

9

Support Line Sensor Alarm

9

9

9

Transmit 'No Read' message on sensor timeout

9

9

9

Scans per Sensor Activation (1-5)

9

9

9

Scan Duration (sec.)

9

9

9

Support Triac

9

9

9

Triac Controlled by the Host (DC2/DC4)

9

9

Triac Normally On

9

9

9

Enable Read and Match Mode

9

9

9

Содержание HoloTrak IS8300

Страница 1: ...METROLOGIC INSTRUMENTS INC HoloTrak IS8000 Series Holographic Scanners Installation and User s Guide...

Страница 2: ......

Страница 3: ...1 48 63 24 94 Email info fr metrologic com CHINA SUZHOU Metro Technologies Co Ltd SPAIN MADRID Tel 86 512 62572511 Fax 86 512 62571517 Metrologic Eria Ib rica SL Email info cn metrologic com Tel 34 91...

Страница 4: ...nd Running the MetroSet 2 Program 8 Parts of the Scanner 10 Mounting Bracket Installation 11 Visual and Audible Indicators 12 Labels 13 Depth of Field and Scan Pattern Characteristics IS8300 Depth of...

Страница 5: ...is based conservatively on a 0 33 mm 0 013 bar code width Actual scan areas will vary by label size and application The area defined is based conservatively on a 0 25 mm 0 010 bar code width Actual sc...

Страница 6: ...00 only MX008 High Volume Speaker MLPN 52 52206 3 7 meter 12 ft Communication Cable MLPN 45 45745 MX001 for Single Scanner Setup MX001 Industrial Controller MLPN 52 52708 Communication Cable MLPN 45 4...

Страница 7: ...o connect or daisy chain two scanners together to act as one scanner interfacing with only one host PRIMARY SECONDARY COVERAGE WITH ONE HOST AND TWO HOLOTRAKS Single Conveyor Two Conveyors IS8300 12 3...

Страница 8: ...primary scanner and to the host 3 Connect the Primary Secondary cable to the primary scanner and the secondary scanner 4 Check the AC input requirements of the power supplies for both scanners to mak...

Страница 9: ...ensor Alarm Special configuration of the MX001 Industrial controller is necessary for proper installation Please refer to the MX001 Industrial Control Interface Installation and User s Guide MLPN 00 0...

Страница 10: ...tem 2 Connect the communications cable to the HoloTrak and to the host 3 Connect the External MX008 cable to the HoloTrak and the MX008 4 Check the AC input requirements of the power supply for the sc...

Страница 11: ...the scanner to make sure the voltage matches the AC outlet 5 Connect the power supply to the HoloTrak 6 Plug the power supply into the AC outlet 7 Power up the host system When the hand held scanner...

Страница 12: ...guration is downloaded to the primary scanner the primary will automatically configure the HoloTrak secondary scanner This step is necessary in order to configure the secondary scanner properly For al...

Страница 13: ...the equipment 4 Power up the scanner 5 Turn on the PC 6 From your Start menu choose Programs MetroSet 2 MetroSet 2 7 Select Holotrak as the unit to configure 8 Then choose Configure 9 For detailed ins...

Страница 14: ...Laser Output Window This aperture emits and receives laser light f D type Connector Area This area contains four D type male connectors a 25 pin 15 pin and two 9 pin D sub connectors The 25 pin connec...

Страница 15: ...r with the channels on the mounting bracket 3 Slide the unit into place until the scanner bolts sit securely in the bottom of the channels 4 Rotate the unit to the desired angle and secure into place...

Страница 16: ...as not been successfully read If handshaking is being used the green LED goes out when proper handshaking has completed When the green light turns off communication to the host is complete Alternating...

Страница 17: ...13 LABELS A C D B...

Страница 18: ...ND SCAN PATTERN CHARACTERISTICS IS8300 Depth of Field and Scan Pattern The depth of field area defined is based conservatively on a 0 25 mm 0 010 bar code width Actual scan areas will vary by label si...

Страница 19: ...ND SCAN PATTERN CHARACTERISTICS IS8400 Depth of Field and Scan Pattern The depth of field area defined is based conservatively on a 0 33 mm 0 013 bar code width Actual scan areas will vary by label si...

Страница 20: ...ND SCAN PATTERN CHARACTERISTICS IS8500 Depth of Field and Scan Pattern The depth of field area defined is based conservatively on a 0 33 mm 0 013 bar code width Actual scan areas will vary by label si...

Страница 21: ...ND SCAN PATTERN CHARACTERISTICS IS8800 Depth of Field and Scan Pattern The depth of field area defined is based conservatively on a 0 33 mm 0 013 bar code width Actual scan areas will vary by label si...

Страница 22: ...g of a bar code Therefore the output window will need occasional cleaning 1 Spray optical quality cleaning fluid onto lint free nonabrasive cleaning cloth 2 Gently wipe the output window Do not use so...

Страница 23: ...connection at the host and scanner The communication cable is damaged Replace the communication cable The unit scans but does not communicate with the host Scanner configuration settings have been lo...

Страница 24: ...2 720 mm 28 720 mm 28 460 mm 18 Width 460 mm 18 560 mm 22 560 mm 22 310 mm 12 Conveyor speed 1 5 mps 300 fpm 1 5 mps 300 fpm 1 5 mps 300 fpm 1 5 mps 300 fpm Mechanical Length 349 mm 13 75 349 mm 13 75...

Страница 25: ...r power average 1 mW 1 mW 1 mW 1 mW Laser class CDRH Class II Class II Class II Class II Laser class EN Class 2 Class 2 Class 2 Class 2 Environmental Operating Temperature 0 C to 40 C 32 F to 104 F St...

Страница 26: ...upports a function a check mark appears on the chart PARAMETER DEFAULT RS 232 RS 422 LIGHT PEN INTERFACE FORMAT RS 232 RS 422 9 9 Light Pen 9 No Comm Test Mode Only CODE TYPES All UPC EAN 9 9 9 Code 3...

Страница 27: ...9 9 9 Two Compare Buffers 9 9 9 Four Compare Buffers 9 9 9 Eight Compare Buffers 9 9 9 Scan Count 9 9 9 Reverse LED convention 9 9 9 Support multiple beep B razz Z commands 9 9 Support host BEL CAN ca...

Страница 28: ...9 9 9 Save read and match bar code if power down 9 9 9 SCAN RANGE Close Extended and Normal Extended 9 9 9 RESERVE CODES Reserve Code 1 99 9 9 9 RS232 FORMAT BAUD 300 38 400 9600 9 9 DATA FORMAT Odd S...

Страница 29: ...ars Code 39 Spaces Code 39 Spaces Code 39 Bars as scanned Spaces as scanned Spaces as scanned 9 OPTIONS Extra Transition before Bar Code 9 50x element border 9 10x narrow element border 9 1 0 ms narro...

Страница 30: ...ransmit Code 39 Mod 43 check digit 9 9 SYMBOL LENGTH ITF variable length 50 char 14 char lock 9 9 9 Min 1 50 4 9 9 9 Lock 0 50 0 9 9 9 BEEPER TONE Normal Alt1 Alt 2 Alt3 Alt4 None Normal 9 9 9 LED Fla...

Страница 31: ...ut 21 Reserved 22 Reserved 23 Reserved 24 Reserved 25 Ground RS 232 Cable Note Cables for RS 232 should leave the RS 422 pins unterminated at the scanner RS 422 Cable Note Cables for RS 422 should lea...

Страница 32: ...ort 9 Power Ground DESCRIPTION PIN SIGNAL 1 Flip Sense 2 Data 3 Decode LED 4 Reserved 5 Proximity Detect Connector Type on Scanner DEC9P D Type 9 Pin Male 6 Laser Motor Control 7 Ground 8 Shield Funct...

Страница 33: ...Metrologic has been subjected to abuse misuse neglect improper installation or accident nor any damage due to use or misuse produced from integration of the Product into any mechanical electrical or...

Страница 34: ...cified herein may result in hazardous laser light exposure Under no circumstances should the customer attempt to service the laser scanner Never attempt to look at the laser beam even if the scanner a...

Страница 35: ...ser anche se credete che lo scanner non sia attivo Non aprite mai lo scanner per guardare dentro l apparecchio Facendolo potete esporVi ad una esposizione laser rischiosa L uso di apparecchi ottici eq...

Страница 36: ...5 140 144 5 149 950 5 180 904 5 200 599 5 229 591 5 247 162 5 250 790 5 250 791 5 250 792 5 262 628 5 280 162 5 280 164 5 304 788 5 321 246 5 324 924 5 396 053 5 396 055 5 408 081 5 410 139 5 436 440...

Страница 37: ...28 default settings 8 22 26 depth of field 1 14 15 16 17 21 design specifications 20 21 E electrical power supply 2 7 19 F failure indicator s 12 19 H host 3 4 5 6 7 8 9 12 19 23 I indicators 10 12 in...

Страница 38: ...34 INDEX specifications 20 21 system interfaces 1 8 20 22 T tones 6 transformers 9 troubleshooting 19 V ventilation 21 visual 10 12 voltage 21 W warranty 29 weight 21 window 2 10 18 19...

Страница 39: ......

Страница 40: ...January 2004 Printed in the USA 0 0 0 2 3 7 7...