background image

13

S

CANNER 

P

ARTS

n

 Output Window

o

 Red LED

p

 Green LED

q

 Speaker

r

 Side Cover

s

 Cable Door

t

  Cable Jack Cover

u

  Horizontal Mount Base

v

Multi-Function Button

(see page 14)

w

Cable Connection Area

Foam Insert

Figure 7b:

  Scanner Parts

Figure 7a:

  Scanner Parts

Содержание ARGUSSCAN MS7220

Страница 1: ...METROLOGIC INSTRUMENTS INC MS7220 ArgusSCAN Presentation Laser Scanner Installation and User s Guide...

Страница 2: ......

Страница 3: ...ke Email info uk metrologic com Hampshire RG21 6XG ASIA Singapore Metrologic Asia Pte Ltd Tel 65 6842 7155 No 8 Kaki Bukit Place Fax 65 6842 7166 4th Floor Email info sg metrologic com Singapore 41618...

Страница 4: ...dible Indicators 15 Failure Modes 16 Visual Indicators 17 Labels 18 Maintenance 18 Depth of Field Specifications 19 Depth of Field by Minimum Bar Code Element Width 20 Troubleshooting Guide 22 RS232 D...

Страница 5: ...er replaceable cables MetroSet 2 MetroSelect and MetrOPOS compatible Data editing parsing capability using Bits n Pieces A 2 year warranty SCANNER INTERFACE 7220 12 RS232 Light Pen Keyboard Wedge Stan...

Страница 6: ...andard 2 1m 7 straight cord short strain relief MLPN 54 54xxx Optional 2 7m 9 coiled cord long strain relief MLPN 53 53xxx xxx specifies connection to the host Keyboard Wedge PowerLink Cable Kit for u...

Страница 7: ...stand Slide on the cable door and remove the foam insert Loosen the lock nut push back the metal base plate and then slide the cable through the cable opening Mounting the MS7220 Peel off the base pl...

Страница 8: ...n the scanner Before continuing determine what communication interface is needed then follow the installation procedure for that interface on pages 5 11 It is important to use the correct communicatio...

Страница 9: ...ble 6 Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet 7 Connect AC power to the transformer The outlet should be near the equipment and easily access...

Страница 10: ...canner into the serial port of the PC does not guarantee that scanned information will appear at the PC A software driver and correct configuration setting are also required for proper communication t...

Страница 11: ...nect the external power supply to the power jack on the PowerLink cable 7 Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet 8 Connect AC power to the t...

Страница 12: ...he voltage matches the AC outlet 8 Connect AC power to the transformer The outlet should be near the equipment and easily accessible 9 Slide the cable cover into place on the back of the scanner then...

Страница 13: ...able 6 Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet 7 Connect AC power to the transformer The outlet should be near the equipment and easily acces...

Страница 14: ...TERFACES Step 10 page 9 continued For RS232 Communication Scan 1 st 9 9 9 9 9 8 Recall Defaults Scan 2 nd 4 1 5 5 5 4 Enable RS 232 For Light Pen Communication Scan 1 st 9 9 9 9 9 8 Recall Defaults Sc...

Страница 15: ...rLink cables Before continuing verify that the powerlink cable is connected to the appropriate interface jack on the scanner An incorrect cable connection can cause communication problems or potential...

Страница 16: ...code applies for all scanners except the MS6720 to be used as an auxiliary scanner Contact a Metrologic representative for information on the MS6720 12 Configure the MS7220 to activate the auxiliary...

Страница 17: ...indow o Red LED p Green LED q Speaker r Side Cover s Cable Door t Cable Jack Cover u Horizontal Mount Base v Multi Function Button see page 14 w Cable Connection Area Foam Insert Figure 7b Scanner Par...

Страница 18: ...rd signifying the new setting has been stored in memory The silent no beep tone is also selectable PLACING THE UNIT IN SLEEP MODE Long 3 seconds depression Puts the scanner in the sleep mode WAKING TH...

Страница 19: ...his is a failure indicator Refer to failure modes page 16 Three Beeps during operation When placing the scanner in program mode the red LED will flash while the scanner simultaneously beeps three time...

Страница 20: ...r failure Return the unit for repair at an authorized service center Continuous Razzberry Tone with both LEDs off If upon power up the scanner emits a continuous razzberry tone then the scanner has an...

Страница 21: ...ly reads a bar code the red LED will flash and the scanner will beep once If the red LED does not flash or the scanner does not beep once then the bar code has not been successfully read Steady Green...

Страница 22: ...has been molded into the back of the case The following is an example of the back of the case with the label and molded text Figure 9 Back view of the case MAINTENANCE Smudges and dirt can interfere...

Страница 23: ...DEPTH OF FIELD SPECIFICATIONS BASED ON 100 UPC BAR CODES Depth of Field default Figure 10 Top View of Depth of Field Figure 11 Side View of Depth of Field Specifications subject to change without noti...

Страница 24: ...LEMENT WIDTH BASED ON 100 UPC BAR CODES Depth of Field Default Figure 12 Top View of Depth of Field Specifications subject to change without notice Minimum Bar Code Element Width A B C D E F mm 13 19...

Страница 25: ...LEMENT WIDTH BASED ON 100 UPC BAR CODES Depth of Field Default Figure 13 Side View of Depth of Field Specifications subject to change without notice Minimum Bar Code Element Width A B C D E F mm 13 19...

Страница 26: ...nt to power ArgusScan Use the power supply included with the scanner 3 beeps on power up Non volatile RAM failure Contact a Metrologic Representative if the unit will not hold the programmed configura...

Страница 27: ...host handshaking but is not receiving the signal If the scanner is setup to support ACK NAK RTS CTS XON XOFF or D E verify that the host cable and host are supporting the handshaking properly The unit...

Страница 28: ...symbology The minimum symbol length setting does not work with the bar code Check if the correct minimum symbol length is set Keyboard Wedge Only The unit scans the bar code but there is no data Confi...

Страница 29: ...ow as lower case Computer is in Caps Lock mode Enable Caps Lock detect setting of the scanner to detect whether the PC is operating in Caps Lock Everything works except for a couple of characters Thes...

Страница 30: ...y needs to be added to the transmitted output Add some intercharacter delay to the transmitted output by using the MetroSelect Programming Guide MLPN 00 02407 Slave operation with any interface Troubl...

Страница 31: ...ware and the scanner configuration match If the application does not support RS 232 scanners a software wedge program that will take RS 232 data and place it into a keyboard buffer may be needed This...

Страница 32: ...functions available in other Metrologic scanners are also available as keyboard wedge functions The following are the most important selectable options specific to the keyboard wedge Keyboard Type AT...

Страница 33: ...m Interfaces PC Keyboard Wedge RS 232 OCIA Light Pen Stand Alone PC Keyboard Print Contrast 35 minimum reflectance difference No Characters Read up to 80 data characters Maximum number will vary based...

Страница 34: ...0825 1 1994 A11 1996 Class 1 EMC FCC ICES 003 EN 55022 Class A ENVIRONMENTAL Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 40 C to 60 C 40 F to 140 F Humidity 5 to 95 relative hu...

Страница 35: ...the following pages a check mark will appear Parameter Default OCIA RS 232 Light Pen IBM 46XX KBW UPC EAN a a a a a Code 128 a a a a a Code 93 a a a a a Codabar a a a a a Interleaved 2 of 5 ITF a a a...

Страница 36: ...er Save Mode 10 mins a a a a a Same Symbol Rescan Timeout 200 msecs a a a a a Same Symbol Rescan Timeout 500 msecs Programmable in 50 msec steps MAX 6 35 seconds a a a a a Same Symbol Rescan Timeout 1...

Страница 37: ...r Start Stop Characters a a a a CLSI Editing Enable a a a a Transmit Mod 43 Check Digit on Code 39 a a a a Transmit Code 39 Stop Start Characters a a a a Transmit Mod 10 ITF a a a a Transmit MSI Pless...

Страница 38: ...RTS CTS Handshaking a Character RTS CTS a Message RTS CTS a XON XOFF Handshaking a ACK NAK a Two Digit Supplements a a as code 39 a a Five Digit Supplements a a as code 39 a a Bookland 978 a a as code...

Страница 39: ...Suffix Characters a Prefixes for individual Code Types Editing a a a a a Inter Scan Code Delay Programmable 100 sec steps 800 sec a Function Control Key Support Minimum Element Width Programmable in 5...

Страница 40: ...A RS 232 Light Pen IBM 46XX KBW Aux Baud Rate 38400 a a a a a Aux parity space a a a a a Aux data bits 7 a a a a a Aux stop bits 2 a a a a a Aux character RTS a a a a a Aux message RTS a a a a a Aux A...

Страница 41: ...er Phillips head screw driver 20 wrench Drill with 39 drill bit Needed for hard mount installation only Optional Flex Stand Kit MLPN 46 46404 See page 39 for installation instructions Kit Includes a L...

Страница 42: ...cover plate Mounting the MS7220 Peel off the base plate s tape backing and affix it to the countertop or drill four 39 pilot holes and secure the base plate to the countertop with the four 8 wood scre...

Страница 43: ...f the base plate s tape backing and affix it to the countertop or drill four 39 pilot holes and secure the base plate to the countertop with the four 8 wood screws provided Slide the bearing plate ove...

Страница 44: ...Receive Input 4 RDATA 5 RDATA Return 6 Clock in 7 Clock out 8 Clock in Return Clock out Rtrn 9 5VDC 10 Shield Ground MS7220 12 Keyboard Wedge or Stand Keyboard MS7220 12 RS 232 or Light Pen Pin Funct...

Страница 45: ...erLink cable 9 pin D type female connector to the PC Pin Function 1 Shield Ground 2 RS 232 Transmit Output 3 RS 232 Receive Input 4 DTR Input 5 Power Signal Ground 6 Reserved 7 CTS Input 8 RTS Output...

Страница 46: ...ing to the keyboard and the keyboard port on the PC The pin assignments are as follows PowerLink Cable Adapter Cable 5 pin Female DIN 5 pin Male DIN Pin Function Pin Function 1 Keyboard Clock 1 PC Clo...

Страница 47: ...een subjected to abuse misuse neglect improper installation or accident nor any damage due to use or misuse produced from integration of the Product into any mechanical electrical or computer system T...

Страница 48: ...car una luz de l ser peligrosa Bajo ninguna circunstancia el usuario deber realizar el mantenimiento del l ser del esc ner Ni intentar mirar al haz del l ser incluso cuando este no est operativo Tampo...

Страница 49: ...5 777 315 5 789 731 5 828 049 6 029 894 4 360 798 4 369 361 4 387 297 4 460 120 4 496 831 4 593 186 4 607 156 4 673 805 4 736 095 4 758 717 4 816 660 4 845 350 4 896 026 4 923 281 4 933 538 4 992 717...

Страница 50: ...Keyboard Type 28 Keyboard Wedge1 2 7 28 29 40 L Labels 18 LED 13 15 17 22 23 29 Light Levels 30 Light Pen 1 2 9 10 29 36 40 Light Source 29 M Maintenance 18 Mechanical 29 Min Bar Width 29 N Normal Dep...

Страница 51: ......

Страница 52: ...April 2002 Printed in USA 0 0 0 2 5 5 4 A...

Отзывы: