![Metrohm Autosampler plus 919 IC Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/metrohm/autosampler-plus-919-ic/autosampler-plus-919-ic_manual_1779630040.webp)
6.2 Remote interface
■■■■■■■■■■■■■■■■■■■■■■
32
■■■■■■■■
919 IC Autosampler plus
The input lines can be scanned with the
SCAN
command.
Outputs
Open Collector
tp
t
p
> 200 ms
active = low, inactive = high
I
C
= 20 mA, V
CEO
= 40 V
+5 V: maximum load = 20 mA
The output lines can be set with the
CTRL
command.
Table 3
Inputs and outputs of the remote interface
Assignment
Pin no.
Assignment
Pin no.
Input 0
21
Output 0
5
Input 1
9
Output 1
18
Input 2
22
Output 2
4
Input 3
10
Output 3
17
Input 4
23
Output 4
3
Input 5
11
Output 5
16
Input 6
24
Output 6
1
Input 7
12
Output 7
2
0 volts / GND
14
Output 8
6
+5 volt
15
Output 9
7
0 volts / GND
25
Output 10
8
Output 11
13
Output 12
19
Output 13
20
Содержание Autosampler plus 919 IC