page 2
All Metro wood fires are packed in a single heavy-duty carton,
and bolted to a wooden pallet. Having removed the packaging
and located this manual, familiarise yourself with the illustrations
on pages 2 & 3, and proceed as detailed below.
Please note: you should only assemble this wood fire if you are
suitably experienced in wood fire assembly and installation.
Note: The Metro carton shows the model Metro you are about to install,
enabling you to select the apppropriate model’s assembly instructions.
Metro Radiant Fires
These Metro’s are supplied virtually fully assembled. Packed inside
the firebox you will find bricks in a cardboard wrapper, a wire door
handle and the air control wire handle.
• Remove the two securing bolts located at the base of each
rear leg which secure the Metro to the wooden pallet, and
carefully “walk” the Metro off the pallet.
• Open the door fully and fit the side bricks to each side of the
firebox. Location lugs are fitted to the base and rear of the
firebox to retain the side bricks in position. Refer to Diagram 2.
• Attach the door handle to the door latch assembly by
screwing it on clockwise.
• Attach the air control wire handle by screwing it on clockwise.
Assembling your Metro wood fire
This Metro wood fire has been tested to and complies with
AS/NZS2918:2001 when installed in accordance with this
manual. Please ensure you are fully conversant with this relevant
standard and the contents of this manual. Correct installation is
critical to the safe operation and performance of this wood fire.
Please take particular note of the following:
• It is recommended that Metro’s be installed with a Metro
ECO flue system which has been developed to enhance
the performance of Metro wood fires. Any alternative
flue system must have a minimum flue pipe length of 4.2
metres of 150mm diameter flue pipe.
• The 150mm active flue pipe must be fully encased from
the ceiling to the underside of the flashing cone at the top
of the flue system, (i.e. there must not be any 150mm flue
pipe exposed).
• All flue pipe joints must be sealed and riveted. The bottom
of the flue pipe in particular MUST be fully sealed into the
flue outlet of the Metro wood fire.
• In New Zealand, the Metro must be bolted through the
floor protector into the floor to comply with the seismic
restraint provisions of AS/NZS2918:2001
• All Metro’s are extremely heavy, varying in weight from
85kgs up to 150kgs. During the installation process do
not lift the appliance by yourself, and take care not to
damage the panel coating.
• Mixing of appliance or flue-system components
from different sources or modifying the dimensional
specification or components may result in
hazardous conditions.
Where such action is considered, the manufacturer
should be consulted in the first instance.
• Do not install a Metro if there is any sign of visible
damage
CaUTION!
Important Information
• WE HIGHLY RECOMMEND YOU READ THIS ENTIRE
MANUAL AS INCORRECT OPERATION AND/OR LACK
OF MAINTENANCE WILL VOID THE WARRANTY
• The appliance and flue-system shall be installed in
accordance with AS/NZS 2918 and the appropriate
requirements of the relevant building code or codes
• Any modification of the appliance that has not
been approved in writing by the testing authority is
considered to be in breach of the approval granted
for compliance with AS/NZS 4013
WaRNINg!
Important Information
AIR CONTROL
WIRE HANDLE
DOOR
HANDLE
Radiant Fires
Содержание ECO Euro Ped