All Metro wood fires are packed in a single heavy-duty carton, 
and bolted to a wooden pallet. Having removed the packaging 
and located this manual, familiarise yourself with the illustrations 
on pages 2 & 3, and proceed as detailed below.

Please note: you should only assemble this wood fire if you are 
suitably experienced in wood fire assembly and installation.

Note: The Metro carton shows the model Metro you are about to install, 
enabling you to select the apppropriate model’s assembly instructions.

Metro Radiant Fires

These Metro’s are supplied virtually fully assembled. Packed inside 
the firebox you will find bricks in a cardboard wrapper, a wire door 
handle and the air control wire handle.
•  Remove the two securing bolts located at the base of each 

rear leg which secure the Metro to the wooden pallet, and 
carefully “walk” the Metro off the pallet. 

•  Open the door fully and fit the side bricks to each side of the 

firebox. Location lugs are fitted to the base and rear of the 
firebox to retain the side bricks in position. Refer to Diagram 2.

•   Attach the door handle to the door latch assembly by 

screwing it on clockwise. 

•   Attach the air control wire handle by screwing it on clockwise.

Assembling your Metro wood fire

This Metro wood fire has been tested to and complies with 
AS/NZS2918:2001 when installed in accordance with this 
manual. Please ensure you are fully conversant with this relevant 
standard and the contents of this manual. Correct installation is 
critical to the safe operation and performance of this wood fire.

Please take particular note of the following:

•  It is recommended that Metro’s be installed with a Metro 

ECO flue system which has been developed to enhance 
the performance of Metro wood fires. Any alternative 
flue system must have a minimum flue pipe length of 4.2 
metres of 150mm diameter flue pipe.

•  The 150mm active flue pipe must be fully encased from 

the ceiling to the underside of the flashing cone at the top 

of the flue system, (i.e. there must not be any 150mm flue 
pipe exposed).

•  All flue pipe joints must be sealed and riveted. The bottom 

of the flue pipe in particular MUST be fully sealed into the 
flue outlet of the Metro wood fire.

•  In New Zealand, the Metro must be bolted through the 

floor protector into the floor to comply with the seismic 
restraint provisions of AS/NZS2918:2001

•  All Metro’s are extremely heavy, varying in weight from 

85kgs up to 150kgs. During the installation process do 
not lift the appliance by yourself, and take care not to 
damage the panel coating.

•  Mixing of appliance or flue-system components 

from different sources or modifying the dimensional 

specification or components may result in 

hazardous conditions. 

Where such action is considered, the manufacturer 

should be consulted in the first instance.

•  Do not install a Metro if there is any sign of visible 

damage

 CaUTION! 

Important Information

•   WE HIGHLY RECOMMEND YOU READ THIS ENTIRE 

MANUAL AS INCORRECT OPERATION AND/OR LACK 

OF MAINTENANCE WILL VOID THE WARRANTY

•   The appliance and flue-system shall be installed in 

accordance with AS/NZS 2918 and the appropriate 

requirements of the relevant building code or codes

•   Any modification of the appliance that has not 

been approved in writing by the testing authority is 

considered to be in breach of the approval granted 

for compliance with AS/NZS 4013

 WaRNINg! 

Important Information

AIR CONTROL 
WIRE HANDLE

DOOR 

HANDLE

Radiant Fires

Содержание ECO Euro Ped

Страница 1: ...pecifications 6 Wetback and flue installation 7 Operation important information 8 Where to install a Metro in your home 9 Optional wetbacks 9 Getting to know your Metro 10 Operating your Metro 10 Clea...

Страница 2: ...Metro s be installed with a Metro ECO flue system which has been developed to enhance the performance of Metro wood fires Any alternative flue system must have a minimum flue pipe length of 4 2 metre...

Страница 3: ...n the pedestal with its front facing over the 4 bolts and fit the washers and nuts supplied check to ensure the pedestal is correctly aligned and securely tighten the nuts It is recommended that 2 peo...

Страница 4: ...ions onto a floor which has a free air supply below it DV CEILING KIT For installations when the Metro is installed against an internal wall and on a concrete floor DV Ceiling kit goes into the wall c...

Страница 5: ...tector is on a concrete floor or coach bolts if a wooden floor secure through the holes provided at the base behind both rear legs Note the anchors must pass through the floor protector and securely a...

Страница 6: ...hown are in mm with a Pioneer double flue shield fitted Model A B C D E F G H I J K L M ECO Tiny Rad 225 552 580 420 150 200 300 75 805 650 1165 925 250 ECO Tiny Ped 210 430 580 290 25 200 185 60 790...

Страница 7: ...erence of the wetback which will face the inside rear wall of the firebox This will completely seal the wetback to the inside rear wall of the fire on installation 6 Fit the wetback into the firebox a...

Страница 8: ...be operated with over worn faulty or missing door seals Door seals will harden over time and become over worn 3 4 year s this will cause air to leak into the fire causing the appliance to over fire It...

Страница 9: ...r local territorial authority council you may or may not be able to install a water heating device If in doubt consult your local Metro retailer Water heating is another key feature of your Metro wood...

Страница 10: ...the firebox Add dry kindling and move the air control knob fully to the right being the full open position Light the paper at two or three locations across the front of the door opening and leave the...

Страница 11: ...moval The time this build up takes depends on the density and cleanliness of your fuel To remove the excess ash your Metro should not be operating Open the door and using a hearth shovel or similar em...

Страница 12: ...but its starting too and is getting worse The pipe is in need of a clean It is recommended that the flue pipe to be cleaned every season however if you are burning the fire on low a lot or are using...

Страница 13: ...een neglected by not being regularly maintained and serviced warranty may be declined It is critical that the fire not be operated with over worn faulty or missing door seals Door seals will harden ov...

Страница 14: ...s renewable fuel is compressed into a dense pellet allowing for maximum heat to be released Check out Metro s new flame today Metro Solar Systems Metro Solar brings together Pioneer Manufacturing Ltd...

Страница 15: ...od fire keeping it in good order for many years to come Pioneer heating accessories ECO Flue Systems Pioneer Flashrites Pioneer Versatiles Lead Aluminium Silicone Pioneer Fire Cement Pioneer Fireguard...

Страница 16: ......