metrofires ECO Euro Ped Скачать руководство пользователя страница 13

PAGE 13

Metro wood fires are manufactured in New Zealand, using 
the highest quality of materials, workmanship and the latest 
manufacturing techniques, which is why we offer a full 10 year 
firebox warranty and 1 year parts warranty for peace of mind. 

Metro Warranty 
(NZ Consumer laws apply to this warranty)

Pioneer Manufacturing Limited (Pioneer) warrants the steel 
firebox against defective materials and workmanship which 
would render it unfit for normal domestic use, from the date of 
purchase by the original consumer, for a period of 10 years. 

Components including panel coating, door retainers, door 
seals, glass, trim, baffle & bricks are warranted for a period 
of 1 year from the date of original purchase for domestic use 
against defective materials and workmanship. 

All associated accessories including, but not limited to, fans, 
flue systems, flue shields, wetbacks, tool sets, ash pots etc, 
are covered by a 1 year warranty against defective materials 
and workmanship.

It is recommended, but not a condition of this warranty, that a 
full service/inspection of the Metro wood fire be carried out at 
the end of each winter season.

Warranty Conditions:

•   The Metro wood fire must be installed, operated and 

maintained strictly in accordance with the building code and 
this installation and operation manual.

•  The Metro wood fire must be installed and used in a 

domestic application.

•   This warranty covers appliance like for like replacement or 

repair at the manufacturer’s discretion but excludes freight, 
travel, installation, labour and/or any other associated costs.

•   Pioneer or their agents are not liable for any loss or expense 

direct or indirect arising from the failure of any part or 
operation of the appliance.

•   Operation of this appliance in violation of the warnings in 

this operation and installation manual will void this warranty. 

•   Your Metro wood fire must be regularly maintained and we 

recommended it is also serviced annually. Proof of servicing 
may be required. If a wood fire is not regularly maintained 
and serviced, the life span will be reduced. If your Metro 
wood fire has been neglected, by not being regularly 
maintained and serviced, warranty may be declined.

•     It is critical that the fire not be operated with over worn, 

faulty or missing door seals. Door seals will harden over 
time and become over-worn (3-4 year’s) this will cause air 
to leak into the fire, causing the appliance to ‘over fire’.

•  It is critical that the fire not be operated with over worn, 

faulty or missing bricks, baffle plate, baffle extension (white 
board on the baffle plate)

•  It is critical that the fire not be operated with cracked, or 

broken door glass.

Please note, the above 3 points require regular inspection/
maintenance (every time the ash bed is cleaned out, generally 
3-5 times a season) and if not maintained will void the firebox 
warranty. Please ensure you keep your proof of purchase/
receipt on any parts you buy.

•   A claim under this warranty should be directed to the retailer 

who supplied the Metro wood fire. If this is not possible 
write direct to the manufacturer stating details of fault, serial 
number of your Metro, date and proof of purchase and 
name of retailer where the Metro was purchased.

Warranty Exclusions: 
This manufacturer’s warranty does not cover:

•  Service calls which are not related to any defect in the 

product (i.e. operational, installation or fuel issues). The 
cost of a service call will be charged if the problem is not 
found to be a product fault.

•   Defects caused by factors other than normal domestic use 

or use in accordance with the product’s operation manual. 

•   Defects caused through the product being operated in 

an “over-fired” manner resulting in sections of the firebox 
operating excessively hot to the point that sections glow 
red. (Note – This will result in distortion of the firebox)

•   Defects to the product caused by accident, neglect, 

misuse or act of God.

•   The cost of repairs carried out by non-authorised repairers 

or the cost of correcting such unauthorised repairs. 

•   Required maintenance as set out in this manual. 

Service under this manufacturer’s warranty must be provided 
by a repairer authorised by Pioneer Manufacturing Ltd. Such 
service shall be provided during normal business hours.

Warranty details for your Metro wood fire

Purchase Date

Serial Number

Model

Colour

Retailer

 IMPORTANT! 

Complete and retain these details at time of purchase:

Содержание ECO Euro Ped

Страница 1: ...pecifications 6 Wetback and flue installation 7 Operation important information 8 Where to install a Metro in your home 9 Optional wetbacks 9 Getting to know your Metro 10 Operating your Metro 10 Clea...

Страница 2: ...Metro s be installed with a Metro ECO flue system which has been developed to enhance the performance of Metro wood fires Any alternative flue system must have a minimum flue pipe length of 4 2 metre...

Страница 3: ...n the pedestal with its front facing over the 4 bolts and fit the washers and nuts supplied check to ensure the pedestal is correctly aligned and securely tighten the nuts It is recommended that 2 peo...

Страница 4: ...ions onto a floor which has a free air supply below it DV CEILING KIT For installations when the Metro is installed against an internal wall and on a concrete floor DV Ceiling kit goes into the wall c...

Страница 5: ...tector is on a concrete floor or coach bolts if a wooden floor secure through the holes provided at the base behind both rear legs Note the anchors must pass through the floor protector and securely a...

Страница 6: ...hown are in mm with a Pioneer double flue shield fitted Model A B C D E F G H I J K L M ECO Tiny Rad 225 552 580 420 150 200 300 75 805 650 1165 925 250 ECO Tiny Ped 210 430 580 290 25 200 185 60 790...

Страница 7: ...erence of the wetback which will face the inside rear wall of the firebox This will completely seal the wetback to the inside rear wall of the fire on installation 6 Fit the wetback into the firebox a...

Страница 8: ...be operated with over worn faulty or missing door seals Door seals will harden over time and become over worn 3 4 year s this will cause air to leak into the fire causing the appliance to over fire It...

Страница 9: ...r local territorial authority council you may or may not be able to install a water heating device If in doubt consult your local Metro retailer Water heating is another key feature of your Metro wood...

Страница 10: ...the firebox Add dry kindling and move the air control knob fully to the right being the full open position Light the paper at two or three locations across the front of the door opening and leave the...

Страница 11: ...moval The time this build up takes depends on the density and cleanliness of your fuel To remove the excess ash your Metro should not be operating Open the door and using a hearth shovel or similar em...

Страница 12: ...but its starting too and is getting worse The pipe is in need of a clean It is recommended that the flue pipe to be cleaned every season however if you are burning the fire on low a lot or are using...

Страница 13: ...een neglected by not being regularly maintained and serviced warranty may be declined It is critical that the fire not be operated with over worn faulty or missing door seals Door seals will harden ov...

Страница 14: ...s renewable fuel is compressed into a dense pellet allowing for maximum heat to be released Check out Metro s new flame today Metro Solar Systems Metro Solar brings together Pioneer Manufacturing Ltd...

Страница 15: ...od fire keeping it in good order for many years to come Pioneer heating accessories ECO Flue Systems Pioneer Flashrites Pioneer Versatiles Lead Aluminium Silicone Pioneer Fire Cement Pioneer Fireguard...

Страница 16: ......

Отзывы: