4  FC7X00 CONFIGURATION 

On  the  underside  of  the  FC7x00  there  are  bit  switches  available  for  configuration  of  the 
unit.  The  label  shown  below  indicates  which  fibre  interface  module  is  fitted,  and  also 
shows the functions and default positions of the bit switches.   

 

Figure 4:   FC7x00 Base Labels 

The functions of the bit switches are described below: 

4.1  Bit Switch 1: Auto Negotiation 

This  bit  switch  controls  the  auto  negotiation  operation  on  the  10/100BaseT  twisted  pair 
interface.  When Enabled the port will automatically negotiate with the far end to find the 
highest common operation mode.  When Auto Negotiation is disabled, the port speed and 
duplex modes are configured manually according to switch 2 and 4. 

 

SW1-ON   

Auto Negotiation Disabled 

 

SW1-OFF  

Auto Negotiation Enabled 

Note,  that  when  the  FC7x00  is  connected  to  a  non  auto  negotiating  port,  the  auto 
negotiation algorithm can only determine the speed of the link and will always select half 
duplex mode. Thus when used with full duplex ports auto negotiation should be disabled, 
and the speed and duplex selected manually. 

 

Содержание FC7000

Страница 1: ...de DATE 21st September 2009 DOCUMENT NO 76 02 047A REVISION A PREPARED BY Ian Banbrook Metrodata Ltd Fortune House Crabtree Office Village Eversley Way Egham Surrey TW20 8RY UK Tel 44 1 784 744700 Fax...

Страница 2: ...of Metrodata Ltd Fortune House Crabtree Office Village Eversley Way Egham Surrey TW20 8RY United Kingdom DISCLAIMER Metrodata Ltd makes no representations or warranties with respect to the contents h...

Страница 3: ...METRODATA LTD FC7000 Media Converter Installation Guide 76 02 047 Rev A 3 of 12 Document Revision History 20th March 2009 XA Document Created 21st September 2009 09 21 A Document Released...

Страница 4: ...0 CONFIGURATION 7 4 1 Bit Switch 1 Auto Negotiation 7 4 2 Bit Switch 2 Speed 100 Speed 10 8 4 3 Bit Switch 4 Duplex 8 4 4 Bit Switch 5 Auto MDI MDIX 8 4 5 Bit Switch 7 Link State Forwarding 9 5 FC7X00...

Страница 5: ...for the FC7X00 products specific installations may only operate over lower distances due to the variations in losses of different types of fibre cable the use of connecting fibre cables or patch pane...

Страница 6: ...lternatively DC power may be specified where the Mains IEC connector is replaced with a buccaneer type connector for operation over the range 7 to 24V DC 36 to 72V DC 3 2 10 100BaseT RJ45 Port The FC7...

Страница 7: ...ntrols the auto negotiation operation on the 10 100BaseT twisted pair interface When Enabled the port will automatically negotiate with the far end to find the highest common operation mode When Auto...

Страница 8: ...t when auto negotiation is disabled This switch is ignored if auto negotiation is enabled SW4 ON Full Duplex SW4 OFF Half Duplex 4 4 Bit Switch 5 Auto MDI MDIX This switch controls the auto crossover...

Страница 9: ...State Forwarding function When LSF is enabled a fault on one port will propagate to the other port to alert the attached equipment that there is a fault A full description of LSF is found in section 6...

Страница 10: ...00 Rear panel The function of the status LEDs is described below 5 1 10 100BaseT Link Act The green Link Act LED uses a combination of solid or flashing modes to indicate the state of the link and whe...

Страница 11: ...tected on the fibre such as when the fibre is disconnected or broken The states of the LOS LED is as below RED Loss of Signal Fibre Fault GREEN Fibre Signal Detected 5 4 100Base FX Fibre Port Link Act...

Страница 12: ...n response to the remote fault indication received on the fibre port the FC7000 will also force the copper port LINK DOWN When the fibre is restored the FC7000 will detect signal and declare LINK UP a...

Отзывы: