INSTALLATION & SET-UP
7
3 INSTALLATION & SET-UP
3. 1 Setting-up the Bit-switches
The Bit-switches on the base of the unit must be set-up before making any connections to
the unit. There is an explanatory label on the unit’s base which defines the bit-switch set-up
options.
Figure 3. 1 LV2000 Base Panel label
3 . 1. 1 Bit-switch definitions
The default settings of the bit-switch are shown in bold:
Figure 3. 2 Bit-switch definitions
Bit-switch
Control
On
Off
1
Unused
Normal
2
Crypto Resynch
Disabled
Enabled
3
Resynch Mode
Active Low
Active High
4
Resynch Control
LVDS
LVTTL
5
Data Invert
Normal
Inverted
6
Duplex
Half
Full
7
Speed
10M
100M
8
Auto Negotiation
Enabled
Disabled
LVDS LAN CONVERTER (AC)
LV2000
For product manual
and other information:-
Metrodata Ltd
TW20 8RY UK
Tel +44 (0) 1784 744700
Fax +44 (0) 1784 744730
17-08-637A
Part No.80-05-558
OFF
ON
www.metrodata.co.uk
Manufactured in the UK
Serial No:
48708
1 2 3
4 5 6 7 8
This device complies with part 15 of the FCC rules
Operation is subject to the following two conditions:
(1) This device may not cause harmful Interference, and
(2) This device must accept any interference received,
including interference that may cause undesired operation.
Bold character
s = Factory Default
Bitswitch
Control
ON
OFF
1
2
3
5
Resync Control
Normal
Half
Data Invert
Duplex
7
8
Speed
10M
Enabled
Disabled
100M
LVTTL
Inverted
Full
4
6
Normal
Disabled
Active Low
LVDS
Auto Negotiation
Resync Mode
Active High
Crypto Resync
Enabled
Unused
LED Status:
GREEN ON - Unit OK
GREEN FLASH - Link Down
RED FLASH - LVDS Link Down
RED ON - Both Links Down