20
User Guide
Singlemode Fiber Optic Interface — extended long haul distance support
Connector _____________________________________________________ SC
Wavelength _______________________________________________ 1550 nm
RX Input Sensitivity ________________________________ -37 dBm minimum
Output Power ___________________________ -3.0 dBm to 0 dBm (9/125
µ
m)
Supported Link Length __________________________ up to 100km full duplex
Cable Type ______________________ 8.3/125, 8.7/125, 9/125, 10/125
µ
m F/O
Singlemode BWDM Fiber Optic Interface
Connector _____________________________________________________ SC
Supported Link Length ___________________________ up to 20km full duplex
Cable Type ___________________________________________ 9/125
µ
m F/O
(R115-2X, R175-2X)
TX Wavelength ___________________________________________ 1550nm
RX Wavelength ___________________________________________ 1310nm
RX Input Sensitivity ______________________________ -32 dBm minimum
Output Power _________________________ -8 dBm to -15 dBm (9/125
µ
m)
(R115-2Y, R175-2Y)
TX Wavelength ___________________________________________ 1310nm
RX Wavelength ___________________________________________ 1550nm
RX Input Sensitivity ______________________________ -32 dBm minimum
Output Power _________________________ -8 dBm to -15 dBm (9/125
µ
m)
Data Rate
Data Rate __________________________ 44.736Mbps (T3); 34.368Mbps (E3)
Power
Input ____________________________5.0VDC @ 0.4A, 2W average
Environmental
Operating Temperature ____________________________________ 0
°
to 55
°
C
Storage Temperature ____________________________________ -30
°
to 70
°
C
Relative Humidity __________________________ 5% to 95% non-condensing
Weight _______________________________________________ 5 oz (0.14 kg)