![Metro Therm METROAIR AQUA 201 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/metro-therm/metroair-aqua-201/metroair-aqua-201_manual_1779417028.webp)
28
7.3. Mode of operation
Different strategies to heat the water can be selected from the main control panel
pressing 5 or 6 (Scroll down or scroll up) from the home view.
The possible modes of operation to choose from are found in the following table:
Figure 18 – Modes of operation
Class
Code
Menu Item
Description
Er
Er1
T1 Error
The temperature sensor T1 is out of range
Er2
T2 Error
The temperature sensor T2 is out of range
Er3
T3 Error
The temperature sensor T3 is out of range. If T3 Error
occurs, the unit does not heat the water in any way
Er4
T4 Error*
The temperature sensor T4 is out of range. The error Er4 is
ignored and the unit runs normally
Er5
T5 Error*
The temperature sensor T5 is out of range. The error Er5 is
ignored and the unit runs normally
Er6
Err HP
The pressure switch opens, when the pressure in the cool-
ing circuit is above the limit of pressure specified on the
high pressure switch
Er7
Err Evap
The temperature sensor T2 is above T1 - 2°C for more than
one hour
Er8
Err C Evap
The temperature T2 is below - 25°C
Er9
Err H Evap
The temperature T2 is above D11 (Evaporator T max)
Er10
Filter
Replace filter. The alarm is displayed on the main screen,
but the operation of the unit is not affected.