background image

cabinet Replacement paRts list

item no. 

part no. 

Description

  1 

RPC14-042 

HINGE

  2 

RPSEFS-200RDOR 

RIGHT DOOR MBQ-200D UNITS ONLY 

RPSEFS-180RDOR 

RIGHT DOOR MBQ-180D, MBQ-180, MBQ-144 UNITS ONLY

RPSEFS-150RDOR 

RIGHT DOOR MBQ-150D, MBQ-120, MBQ-90 UNITS ONLY

RPSEFS-120RDOR 

RIGHT DOOR MBQ-120D & MBQ-2 UNITS ONLY

  3 

RPC14-118A 

LATCH

  4 

RPSEFS-200LDOR 

LEFT DOOR MBQ-200D UNITS ONLY 

RPSEFS-180LDOR 

LEFT DOOR MBQ-180D UNITS ONLY

RPSEFS-150LDOR 

LEFT DOOR MBQ-150D UNITS ONLY

RPSEFS-120LDOR 

LEFT DOOR MBQ-120D UNITS ONLY

  5 

RPC11-446 

HANDLE

  6 

MBQ-DRGSKT-36 

DR GASKET X 36.313 HI, MBQ-2,-120D 

MBQ-DRGSKT-44 

DR GASKET X 44.813 HI, MBQ-90,-120,-150D 

MBQ-DRGSKT-54 

DR GASKET X 52.813 HI, MBQ-144,-180,-180D 

MBQ-DRGSKT-59 

DR GASKET X 59.313 HI, MBQ-200D

   

RPSHELF-HANG 

SHELF SUPPORT KIT (INCLUDES HARDWARE)

  8 

RP6-SWIVEL 

6” SWIVEL CASTER KIT 

RP8-SWIVEL 

8” SWIVEL CASTER KIT 

HARDWARE INCLUDED

RP8-AIRSWIVEL 

8” SWIVEL AIR CASTER KIT

  9 

RP6-RIGID 

6” RIGID CASTER KIT

RP8-RIGID 

8” RIGID CASTER KIT 

HARDWARE INCLUDED

RP8-AIRRIGID 

8” RIGID AIR CASTER KIT

10 

RPKICK-LATCH 

KICK LATCH KIT

11 

RPC06-201 

BUMPER-SWING HANDLE

12 

RPC13-189 

THERMOMETER (INCLUDES BULB CLAMP)

13 

RPC05-905 

OVERLAY-BEZEL

14 

RPC13-194 

TIMER

15 

RP-WHITEBRD 

WHITE BOARD

16 

RP-BEZELPNL 

BEZEL PANEL

1 

RP-TMRBRKT 

TIMER BRACKET

18 

RPC06-035 

POST CAP

19 

RP-BEZELBUMP 

BEZEL BUMPER KIT MBQ-180, MBQ-144 & MBQ-120 ONLY

20 

RPDD-SHELF 

SHELF — ALL DOUBLE DOOR CABINETS

RP180-SHELF 

SHELF — MBQ-180

RP144-SHELF 

SHELF — MBQ-144 & MBQ-120

RP90-SHELF 

SHELF — MBQ-90 & MBQ-2

21 

RPCF-DDCOV 

CANNED FUEL OPENING COVER-DOUBLE DOOR CABINETS WITH HARDWARE

RPCF-SDCOV 

CANNED FUEL OPENING COVER-SINGLE DOOR CABINETS WITH HARDWARE

22 

RP15AMP-CORD 

120V, 15 AMP POWER CORD

RP20AMP-CORD 

120V, 20 AMP POWER CORD 

RP220V-CORD 

220V, 15 AMP POWER CORD

23 

RPF04-004C 

SWING-UP HANDLE HDWE

24 

RPDD-BUMPER 

CABINET BUMPER ASSEMBLY — DOUBLE DOOR CABINETS

RP180-BUMPER 

CABINET BUMPER ASSEMBLY — MBQ-180 CABINETS ONLY

RP144-BUMPER 

CABINET BUMPER ASSEMBLY — MBQ-144 & MBQ-120 CABINETS ONLY

RP90-BUMPER 

CABINET BUMPER ASSEMBLY — MBQ-90 & MBQ-2 CABINETS ONLY

Содержание MBQ-120-QH

Страница 1: ...are for Food Service applications only This manual covers cabinets with electrical ratings of 120V 1650W 220V 1650W When ordering electrical parts always confirm the rating listed on data plate located on the lower left side of the unit Differences on voltage amps or wattage are listed with bold text in replacement part descriptions ...

Страница 2: ...dule Removal Installation 4 C Quad Heat Dual Fuel Removal Installation 5 D Specific Cleaning Instructions 5 E General Cleaning Instructions 5 IV Maintenance A Cabinet Maintenance 5 B Electric Heating Module 5 C Blower Motor Maintenance 5 V Replacement Parts and Procedures A Cabinet 6 B Electric Heating Module 8 C Battery Replacement Count up Count down Timer Clock 8 D Swivel Lock Operation 9 E Swi...

Страница 3: ...days of delivery of the cabinet Once you have located and recorded these numbers refer to the sample numbers given to the right to identify the components of your cabinet NOTE Please read this manual thoroughly before using your cabinet If you should have questions please contact Metro customer service department Location Of Module serial Number Location of Cabinet Model Number and Serial Number S...

Страница 4: ...into either a 15 amp or 20 amp receptacle Cabinets rated at 220V 1650W must be plugged into a 250VAC 15 amp receptacle NOTE A 15 amp cabinet can be plugged into 20 amp service A 20 amp unit must be plugged into a 20 amp receptacle 2 Snap POWER switch to ON The red POWER light will now glow and the blower will begin circulating air Note This is not a foot switch Operating it with your foot can dama...

Страница 5: ...nets the shelves have two 90 square corners and two 45 notched corners The 45 corners go to the right end as you look into the cabinet B Electric Heating Module removal installation 1 Remove the module from the cabinet by lifting and sliding the module rearward Lift the front of the module and stand it vertically C Count up Count down Timer CLOCK CLOCK MODE 1 Press the Mode button until the clock ...

Страница 6: ...controls area free of dirt build up BE SURE TO THOROUGHLY DRY THE MODULE BEFORE RETURNING IT TO USE 2 Do not neglect to clean the under chassis area especially the area above each caster 3 The cabinet or component s must be thoroughly rinsed to remove any residue that may stain the materials E GENERAL CLEANING INSTRUCTIONS 1 LIGHT SOIL If routine daily cleaning is practiced a mild soap and warm wa...

Страница 7: ...8 1 2 9 6 4 3 19 18 15 16 17 14 13 12 22 V REPLACEMENT PARTS AND REPLACEMENT LIST A Cabinet All Models Refer to the Cabinet Replacement Parts List on page 7 to identify the replacement parts Cabinet Replacement Parts Diagram ...

Страница 8: ...ID 6 RIGID CASTER KIT RP8 RIGID 8 RIGID CASTER KIT HARDWARE INCLUDED RP8 AIRRIGID 8 RIGID AIR CASTER KIT 10 RPKICK LATCH KICK LATCH KIT 11 RPC06 201 BUMPER SWING HANDLE 12 RPC13 189 THERMOMETER INCLUDES BULB CLAMP 13 RPC05 905 OVERLAY BEZEL 14 RPC13 194 TIMER 15 RP WHITEBRD WHITE BOARD 16 RP BEZELPNL BEZEL PANEL 17 RP TMRBRKT TIMER BRACKET 18 RPC06 035 POST CAP 19 RP BEZELBUMP BEZEL BUMPER KIT MBQ...

Страница 9: ... module from the cabinet c Place the module on a dry non flammable work surface CAUTION If necessary to reconnect power while servicing practice extreme caution so as not to receive an electrical shock from exposed components d To replace the thermostat switch or indicator light remove the four screws that hold the control panel to the main body of the module to gain access to the part needing rep...

Страница 10: ... out of the rigid position when the cabinet is moved in tight spaces or around sharp corners without dragging NOTE You must Press down on the swivel lock release loop until the casters are out of the rigid position When you remove your foot from the swivel lock release loop the casters will continue to be free to swivel until the cabinet is pulled for a distance from the opposite side and the cast...

Страница 11: ... MODCORD 22 MODULE CORD 120V 20 AMP RP220 MDLCRD 22 MODULE CORD 220V 15 AMP 2 RPC13 166 HEAT ELEMENT 120V 1650W RPC13 167 HEAT ELEMENT 220V 1650W 3 RPHM20 2103 BLOWER 120V RPHX20 2103 BLOWER 220V 4 RPC13 129 THERMOSTAT 5 RPC06 313 CONTROL KNOB 6 RPC13 245 RED INDICATOR LIGHT 7 RPC13 127 POWER SWITCH 8 RPC13 096 TERMINAL BLOCK 9 RPC13 083 STRAIN RELIEF 15 AMP CORD RPC13 098 STRAIN RELIEF 20 AMP COR...

Страница 12: ...ASE RPSL SDWELD SINGLE DOOR CABINET SWIVEL LOCK RELEASE 2 RPSL RETAIN RELEASE RETAINER BRACKET 3 RPSL6 CASTER 6 SWIVEL LOCK CASTER RPSL8 CASTER 8 SWIVEL LOCK CASTER 4 RPC02 197 6 SWIVEL CASTER RPC02 200 8 SWIVEL CASTER 5 RPSL LOCKTAB SWIVEL LOCK TAB AND HARDWARE E swivel lock caster system replacement parts diagram ...

Страница 13: ...DRAWER RPQH DRAWER RPQH DRAWER RPQH DRAWER RPQH DRAWER 4 FLUE RPQH DDFLUE RPQH DDFLUE RPQH DDFLUE RPQH DDFLUE CABINET MODEL Item No Description MBQ 180 QH MBQ 144 QH MBQ 120 QH MBQ 90 QH MBQ 72 QH 1 CHIMNEY HANGER RPQH HANG RPQH HANG RPQH HANG RPQH HANG RPQH HANG 2 CHIMNEY RPQH 180CHIM RPQH 180CHIM RPQH 150CHIM RPQH 150CHIM RPQH 120CHIM 3 CANNED FUEL DRAWER RPQH DRAWER RPQH DRAWER RPQH DRAWER RPQH...

Страница 14: ...TCH THERMOMETER BULB HEAT THERMOSTAT 23 17 22 16 21 15 24 18 20 14 19 13 11 10 9 12 8 7 5 4 3 6 2 1 18 6 INDICATOR LIGHT WHITE 23 5 4 3 2 8 22 BLOWER ELEMENT TERMINAL BLOCK BLACK GREEN GROUND SCREW GREEN COLOR 21 22 POWER SUPPLY CORD 4 2 18 5 6 21 8 STRAIN RELIEF ...

Страница 15: ...14 InterMetro Industries Corporation hereinafter referred to as Seller warrants to the ...

Страница 16: ...odule Serial No Date Purchased Customer Name Address Phone No For warranty coverage this card must be returned to Metro 2 Please indicate the two product benefits that were of major interest to you a 3 point handle control b Swivel lock caster system maneuverability c Quad Heat Canned Fuel System performance d Easy to clean removable heating module e Hands free access kick latch f Control panel in...

Страница 17: ...e No postage necessary if mailed in the United States Staple Here Postage Will Be Paid By INTERMETRO INDUSTRIES CORPORATION Attn Customer Service P O Box A WILKES Barre PA 18705 9968 Business Reply Mail F irst C lass P ermit N o 1 2 1 wilkes barre PA ...

Страница 18: ...th Washington Street Wilkes Barre PA 18705 For Product Information Call 1 800 433 2232 Visit Our Web Site www metro com L01 399 Rev C 2 08 Information and specifications are subject to change without notice Please confirm at time of order ...