background image

4

III.  CleanIng InsTRUCTIons

 

  CAUTION

 

  AT NO TIME SHOULD THE MODULE OR 

CABINET BE WASHED OR FLOODED WITH 

WATER OR LIQUID SOLUTION. NEVER 

STEAM CLEAN. SEVERE DAMAGE OR 

ELECTRICAL HAZARD COULD RESULT.

 

  . turn off power switch.

 

  2. unplug the unit from its power source.

 

  WARNING

 

  ALLOW THE UNIT TO COOL BEFORE 

CLEANING, AS THE INTERIOR OF THE 

CABINET MAY BE HOT ENOUGH TO BURN.

 

A.  SHELF REMOVAL/INSTALLATION

 

  to remove the shelves, all shelves must first 

be lowered onto the bottom shelf. Start with 

the shelf above the bottom shelf by lifting it off 

of the shelf hangers and by lowering the front 

edge and raising the rear edge so that it can 

be lowered onto the bottom shelf. Repeat the 

procedure until all of the shelves are on the 

stack on the bottom shelf. 

 

  on double door cabinets, lift the uppermost 

shelf off of the stack so that you are holding 

onto the long edge of the shelf and the shelf 

is hanging vertically. Position the shelf so one 

vertical edge is in one of the rear cabinet 

corners. Swing the other vertical edge out the 

door and remove the shelf. Repeat until all the 

shelves are removed. 

 

  on single door cabinets, lift each shelf off of 

the stack so that you are holding onto the long 

edge of the shelf and the shelf is hanging 

vertically. Position the shelf so that one vertical 

edge is in one of the rear cabinet corners and 

the other vertical edge is towards the diagonal 

front corner. Depending on the model of the 

one door cabinet, the shelf may have to be 

rotated towards a vertical position to remove it 

from the cabinet.

 

  to install the shelves, reverse the above 

procedure. Before installing the shelves 

install the module (Section B below) and, if so 

equipped, the Quad-Heat Fuel System baffle(s) 

and chimney(s) (Section c below).

 

 

NOTE:

 the shelf wires that run from left to right 

in the cabinet should be on the top side of the 

installed shelves. Make sure the shelves are 

seated in the hangers correctly.

 

  on single door MBQ-90 and 72 cabinets, the 

shelves have two 90° square corners and two 

45° notched corners. the 45° corners go to the 

right end as you look into the cabinet.

 

B.  ELECTRIC HEATING MODULE 

REMOVAL/INSTALLATION

 

  . Remove the module from the cabinet by 

lifting and sliding the module rearward. Lift 

the front of the module and stand it vertically 

 

C. COUNT-UP/COUNT-DOWN TIMER/CLOCK

 

  CLOCK MODE

 

  . Press the Mode button until the clock icon 

appears on screen next to the printed 

“cLocK” icon.

 

  2. Press and hold (Set) for two seconds.

 

  3. “HouRS” will flash.

 

  4. Press ( 

 ) or ( 

 ) to set.

 

  5. Repeat process to set minutes or seconds.

 

  6. to complete the process press (Set).

 

   

NOTE: 

the two-second delay is to prevent 

accidental changing of time. there is no 

delay in timer mode.

 

  COUNT-DOWN TIMER MODE

 

  can be used to countdown the minutes until the 

canned fuel needs to be replenished.

 

  . Press the Mode button until the timer icon 

appears on the screen next to the printed 

“tiMeR” icon.

 

  2. Press (Set).

 

  3. “HouRS” will flash.

 

  4. Press (

) or (

) to set up or down to desired 

interval (23:59:59 max.).

 

  5. Repeat process to set minutes or seconds.

 

  6. Press (StaRt) to start. Press (StoP) to stop.

 

  HELPFUL HINTS:

 

  •  if you want to set only hours, it is not 

necessary to press (Set) through minutes 

and seconds. Simply set desired interval and 

press (StaRt).

 

  •  as a reminder, your timer will “beep” for 3 

seconds when it reaches 5 minutes before 

set interval expires.

 

  •  When timer reaches 00:00:00 the alarm will 

sound and “tiMe’S uP!” will appear on the 

screen. Your timer will now begin to count 

up. the alarm will stop after 60 seconds and 

your timer will continue to count up until you 

press (StoP).

 

  •  (cLeaR) button can be used at any time 

to clear the display. (cLeaR) button also 

functions for recall of last setting.

 

  •  (RecaLL) feature: after you press (StoP), 

pressing the (RecaLL) button will 

automatically display the last timer setting.

 

  •  each time you press ( 

 ) or ( 

 ) the 

digits will change once. if you hold the button 

down digits will change rapidly.

 

  COUNT-UP TIMER MODE

 

  can be used to track how long food has been in 

the cabinet.

 

  . Press the Mode button until the stop watch 

icon appears on screen next to the printed 

“StoP WatcH” icon.

 

  2. Press (StaRt) to start. Press (StoP) to stop.

Содержание MBQ-120-QH

Страница 1: ...are for Food Service applications only This manual covers cabinets with electrical ratings of 120V 1650W 220V 1650W When ordering electrical parts always confirm the rating listed on data plate located on the lower left side of the unit Differences on voltage amps or wattage are listed with bold text in replacement part descriptions ...

Страница 2: ...dule Removal Installation 4 C Quad Heat Dual Fuel Removal Installation 5 D Specific Cleaning Instructions 5 E General Cleaning Instructions 5 IV Maintenance A Cabinet Maintenance 5 B Electric Heating Module 5 C Blower Motor Maintenance 5 V Replacement Parts and Procedures A Cabinet 6 B Electric Heating Module 8 C Battery Replacement Count up Count down Timer Clock 8 D Swivel Lock Operation 9 E Swi...

Страница 3: ...days of delivery of the cabinet Once you have located and recorded these numbers refer to the sample numbers given to the right to identify the components of your cabinet NOTE Please read this manual thoroughly before using your cabinet If you should have questions please contact Metro customer service department Location Of Module serial Number Location of Cabinet Model Number and Serial Number S...

Страница 4: ...into either a 15 amp or 20 amp receptacle Cabinets rated at 220V 1650W must be plugged into a 250VAC 15 amp receptacle NOTE A 15 amp cabinet can be plugged into 20 amp service A 20 amp unit must be plugged into a 20 amp receptacle 2 Snap POWER switch to ON The red POWER light will now glow and the blower will begin circulating air Note This is not a foot switch Operating it with your foot can dama...

Страница 5: ...nets the shelves have two 90 square corners and two 45 notched corners The 45 corners go to the right end as you look into the cabinet B Electric Heating Module removal installation 1 Remove the module from the cabinet by lifting and sliding the module rearward Lift the front of the module and stand it vertically C Count up Count down Timer CLOCK CLOCK MODE 1 Press the Mode button until the clock ...

Страница 6: ...controls area free of dirt build up BE SURE TO THOROUGHLY DRY THE MODULE BEFORE RETURNING IT TO USE 2 Do not neglect to clean the under chassis area especially the area above each caster 3 The cabinet or component s must be thoroughly rinsed to remove any residue that may stain the materials E GENERAL CLEANING INSTRUCTIONS 1 LIGHT SOIL If routine daily cleaning is practiced a mild soap and warm wa...

Страница 7: ...8 1 2 9 6 4 3 19 18 15 16 17 14 13 12 22 V REPLACEMENT PARTS AND REPLACEMENT LIST A Cabinet All Models Refer to the Cabinet Replacement Parts List on page 7 to identify the replacement parts Cabinet Replacement Parts Diagram ...

Страница 8: ...ID 6 RIGID CASTER KIT RP8 RIGID 8 RIGID CASTER KIT HARDWARE INCLUDED RP8 AIRRIGID 8 RIGID AIR CASTER KIT 10 RPKICK LATCH KICK LATCH KIT 11 RPC06 201 BUMPER SWING HANDLE 12 RPC13 189 THERMOMETER INCLUDES BULB CLAMP 13 RPC05 905 OVERLAY BEZEL 14 RPC13 194 TIMER 15 RP WHITEBRD WHITE BOARD 16 RP BEZELPNL BEZEL PANEL 17 RP TMRBRKT TIMER BRACKET 18 RPC06 035 POST CAP 19 RP BEZELBUMP BEZEL BUMPER KIT MBQ...

Страница 9: ... module from the cabinet c Place the module on a dry non flammable work surface CAUTION If necessary to reconnect power while servicing practice extreme caution so as not to receive an electrical shock from exposed components d To replace the thermostat switch or indicator light remove the four screws that hold the control panel to the main body of the module to gain access to the part needing rep...

Страница 10: ... out of the rigid position when the cabinet is moved in tight spaces or around sharp corners without dragging NOTE You must Press down on the swivel lock release loop until the casters are out of the rigid position When you remove your foot from the swivel lock release loop the casters will continue to be free to swivel until the cabinet is pulled for a distance from the opposite side and the cast...

Страница 11: ... MODCORD 22 MODULE CORD 120V 20 AMP RP220 MDLCRD 22 MODULE CORD 220V 15 AMP 2 RPC13 166 HEAT ELEMENT 120V 1650W RPC13 167 HEAT ELEMENT 220V 1650W 3 RPHM20 2103 BLOWER 120V RPHX20 2103 BLOWER 220V 4 RPC13 129 THERMOSTAT 5 RPC06 313 CONTROL KNOB 6 RPC13 245 RED INDICATOR LIGHT 7 RPC13 127 POWER SWITCH 8 RPC13 096 TERMINAL BLOCK 9 RPC13 083 STRAIN RELIEF 15 AMP CORD RPC13 098 STRAIN RELIEF 20 AMP COR...

Страница 12: ...ASE RPSL SDWELD SINGLE DOOR CABINET SWIVEL LOCK RELEASE 2 RPSL RETAIN RELEASE RETAINER BRACKET 3 RPSL6 CASTER 6 SWIVEL LOCK CASTER RPSL8 CASTER 8 SWIVEL LOCK CASTER 4 RPC02 197 6 SWIVEL CASTER RPC02 200 8 SWIVEL CASTER 5 RPSL LOCKTAB SWIVEL LOCK TAB AND HARDWARE E swivel lock caster system replacement parts diagram ...

Страница 13: ...DRAWER RPQH DRAWER RPQH DRAWER RPQH DRAWER RPQH DRAWER 4 FLUE RPQH DDFLUE RPQH DDFLUE RPQH DDFLUE RPQH DDFLUE CABINET MODEL Item No Description MBQ 180 QH MBQ 144 QH MBQ 120 QH MBQ 90 QH MBQ 72 QH 1 CHIMNEY HANGER RPQH HANG RPQH HANG RPQH HANG RPQH HANG RPQH HANG 2 CHIMNEY RPQH 180CHIM RPQH 180CHIM RPQH 150CHIM RPQH 150CHIM RPQH 120CHIM 3 CANNED FUEL DRAWER RPQH DRAWER RPQH DRAWER RPQH DRAWER RPQH...

Страница 14: ...TCH THERMOMETER BULB HEAT THERMOSTAT 23 17 22 16 21 15 24 18 20 14 19 13 11 10 9 12 8 7 5 4 3 6 2 1 18 6 INDICATOR LIGHT WHITE 23 5 4 3 2 8 22 BLOWER ELEMENT TERMINAL BLOCK BLACK GREEN GROUND SCREW GREEN COLOR 21 22 POWER SUPPLY CORD 4 2 18 5 6 21 8 STRAIN RELIEF ...

Страница 15: ...14 InterMetro Industries Corporation hereinafter referred to as Seller warrants to the ...

Страница 16: ...odule Serial No Date Purchased Customer Name Address Phone No For warranty coverage this card must be returned to Metro 2 Please indicate the two product benefits that were of major interest to you a 3 point handle control b Swivel lock caster system maneuverability c Quad Heat Canned Fuel System performance d Easy to clean removable heating module e Hands free access kick latch f Control panel in...

Страница 17: ...e No postage necessary if mailed in the United States Staple Here Postage Will Be Paid By INTERMETRO INDUSTRIES CORPORATION Attn Customer Service P O Box A WILKES Barre PA 18705 9968 Business Reply Mail F irst C lass P ermit N o 1 2 1 wilkes barre PA ...

Страница 18: ...th Washington Street Wilkes Barre PA 18705 For Product Information Call 1 800 433 2232 Visit Our Web Site www metro com L01 399 Rev C 2 08 Information and specifications are subject to change without notice Please confirm at time of order ...

Отзывы: