Metrix MX8020-001 Скачать руководство пользователя страница 5

Part# 100951

 • REV A

 (January 2018) Page 

5 of 5

 

[email protected]

www.metrixvibration.com 

8824 Fallbrook Dr. Houston, TX 77064, USA

Tel: 1.281.940.1802 • Fax: 1.713.559.9421

After Hours (CST) Technical Assistance: 1.713.452.9703

7. 

Slide the connector onto the center core pin and ferrule.  Be careful to ensure the 

center core pin comes through the connector.  Crimp the connector, using the .178 

hexagon hole, at the ridge line. Test the connection by pulling on the connector with 

approximately 8kg (20lbs) of force. Use the hot air gun to shrink the tubing onto the 

connection.

8. 

Test the modified MX8031 extension cable.  Ensure you have an open circuit between 

the center pin and the connector case.  Ensure you have continuity between the 

cases at both ends of the cable.  Ensure you have continuity between the pin at one 

end and center conductor at the other end.  If any of these checks are not true you 

must do the connection over again.

9.  Ensure you program the Metrix DPS unit (MX2033 or MX2034) for the closest meter 

electrical length that you now have.  Verify the system is linear.  Perform calibration if 

necessary.  For instructions on how to modify the Metrix DPS configuration, from the 

Factory Purchased configuration go to the below link.

         http://www.metrixvibration.com/tenants/metrix/documents/100545.pdf

Отзывы: