4.5.2 Audio Continuity Test
:
:
:
:
Connect the red test lead to the "+" terminal and the black test
lead to the "COM" terminal.
Put the touch prods into contact with the circuit to be tested.
If the resistance value of circuit R<35
Ω
, the buzzer sounds
continuously.
Note: Always check that the circuit is disconnected from the
power supply before measuring continuity!
4.6
°C/°F Temperature Measurement
Set the switch to TEMP.
To measure the temperature,
connect
the
type
K
thermocouple probe to the input
terminals,
observing
the
polarity.
The main display is in degrees
Celsius (°C) by default, and the
secondary display in degrees
Fahrenheit (°F). The user can
change the main display to
degrees Fahrenheit (°F) and
the
secondary
display
to
degrees
Celsius
(°C)
by