Chapter II
Oscilloscope current probe
28
2. CURRENT MEASUREMENT
2.1. MEASUREMENT PRINCIPLE
This probe employs the principle of measuring the flux in a magnetic circuit by a Hall-effect sensor,
allowing measurement of both direct and alternating currents.
Its measurement sensitivity, its metrological capabilities, and its very good frequency response make it
an ideal measurement accessory for oscilloscopes.
The output is a voltage. It can be:
the image of the current: switch set to INST (for instantaneous),
the RMS value of the current: switch set to RMS.
2.2. USE
2.2.1. CONNECTION
Power up the probe by sliding the switch to INST or RMS.
Check that the ON indicator lights. If not, it is time to replace the battery.
The OL indicator lights briefly, then goes off.
Connect the probe to the oscilloscope.
I
I
ON
OL
I
INST
.
RMS
OFF
ZERO
Содержание HX0102
Страница 2: ......
Страница 17: ...Pince oscilloscope Chapitre I 17 3 4 3 R PONSE 14 KHZ ET 250 MA CR TE CR TE...
Страница 23: ...Pince oscilloscope Chapitre I 23...
Страница 37: ...Oscilloscope current probe Chapter II 37 3 4 3 RESPONSE AT 14KHZ AND 250MA PEAK TO PEAK...
Страница 43: ...Oscilloscope current probe Chapter II 43...
Страница 57: ...Zangenstromwandler Kapitel III 57 3 4 3 GANG BEI 14KHZ UND 250MA PEAK TO PEAK...
Страница 63: ...Zangenstromwandler Kapitel III 63...
Страница 77: ...Pinza oscilloscopio Capitolo IV 77 3 4 3 RISPOSTA A 14 KHZ E 250 MA CRESTA A CRESTA...
Страница 83: ...Pinza oscilloscopio Capitolo IV 83...
Страница 97: ...Pinza para osciloscopio Capitulo V 97 3 4 3 RESPUESTA A 14 KHZ Y 250 MA PICO A PICO...
Страница 103: ...Pinza para osciloscopio Capitulo V 103...
Страница 104: ...METRIX Parc des Glaisins 6 avenue du Pr de Challes 74940 ANNECY LE VIEUX T l 33 04 50 64 22 22 Fax 33 04 50 64 22 00...