Metria RST111 Скачать руководство пользователя страница 3

 

 

3

 

1.

 

Safety Instructions 

 

 

Please read this manual carefully before installing or operating this equipment. The instrument shall not 

be modified in any way. Any modification will void the warranty and may result in potential safety hazard. 
We are not responsible for any injury or damage caused by modifying the instrument without authorization. 

 

If the equipment is used in a manner not specified by the manufacturer, the protection provided by the 

equipment may be impaired. The instrument shall not be modified or altered in any way.   

 

We are not responsible for any injury or damage caused by using the instrument for any non-intended 

purpose. 

 

2.

 

Intended use 

 

This refractometer is intended for measuring the refractive index nD and the average dispersion nF - nC of 
transparent or translucent liquid, or solid substance (mainly intended for measuring transparent liquid). In case 
of the instrument being connected with a thermostat, it will be able to measure the refractive index nD at a 
temperature between 0 and 70. 
Both, the refractive index and the average dispersion are the important optical constants, through which we 
can understand the optical performance, purity, concentration, as well as dispersion of a substance. In this 
instrument, based on the formula provided by the International Commission of Uniform Method of Sugar 
Analysis (ICUMSA) in 1974, the refractive index is converted into the mass fraction (Brix) of cane sugar 
solution, with a range of conversion from 0 to 95%. Therefore, this instrument has found an increasingly wide 
utilization in the fields as Petroleum, oil, pharmaceutical, paint, food, chemical and sugar refining industries, 
as well as geological prospecting enterprises, colleges, universities and scientific research institutions. 

 

3.

 

Inspection 

3.1 Receiving Inspection 

Unpack the equipment carefully and check for any damages which may have arisen during transport. Please 
contact your supplier for technical support.  

 

3.2 Listing of Items 

 

The package includes the following items: 

Items in Portable digital 
refractometer 

Qty 

Refractometer 

Batteries 

Carrying case 

Screw driver 

Thermometer 

Standard sample 

Naphthalene bromide sample 

Table 1 

 

 
 
 
 

 

Содержание RST111

Страница 1: ...ABBE Analogic refractometer RST111 Please read the User Manual carefully before use and follow all operating and safety instructions user manual english...

Страница 2: ...are representative with the following information Serial number Description of problem Your contact information Warranty This instrument is warranted to be free from defects in materials and workmansh...

Страница 3: ...perature between 0 and 70 Both the refractive index and the average dispersion are the important optical constants through which we can understand the optical performance purity concentration as well...

Страница 4: ...0 Hand wheel 16 Adjusting cavity 5 Light entering prism holder 11 Refraction prism holder 17 Casing 6 Dispersion adjusting wheel 12 Condensing lens 18 Adapter connector for 4 thermostats 1 Light enter...

Страница 5: ...and 11 the refracting prism holder linked by the rotation shaft 2 the light entering prism can be opened or closed When the two prism holders are tightly closed and locked by the hand wheel 10 a unif...

Страница 6: ...x in the field of view of the eyepiece the operating methods of sighting and reading are the same as above 5 2 3 Measurement of translucent solid Stick the polished surface of the translucent solid to...

Страница 7: ...in the sample to be measured When measuring the solid sample prevent the working surface of the refracting prisms from being roughed and scratched 6 4 Regularly keep the instrument clean Strictly pro...

Страница 8: ...8...

Страница 9: ...ake measuring the average dispersion of distilled water as an example When temperature is 20 nD 1 3330 The reading of dispersion value indicated on the scale ring will be Turn in a certain direction T...

Страница 10: ...tomatically Turn off and put the key for four seconds turn on put the key back on When the temperature is higher than 70 C display will show H when is lower than 50 C display will show L C When the ba...

Страница 11: ...desecharse en vertederos De conformidad con la Directiva 2002 96 CE los usuarios de la Uni n Europea de aparatos el ctricos y electr nicos tienen la oportunidad de retornar el instrumento para su eli...

Страница 12: ...www labbox com...

Отзывы: