background image

MD 9020 Electrical & Electronic DMM Operation 

 

 

Manual or Auto-ranging 

Press the 

RANGE

 button momentarily to select manual-ranging mode, and the meter 

will remain in the range it was in, the LCD annunciator 

 turns off. Press the button 

momentarily again to step through the ranges. Press and hold the button for 1 second 
or more to resume auto-ranging mode. 

Note: Manual ranging mode feature is not available in Hz & Cx functions. 
 

HOLD

 

The hold feature freezes the display for later view. Press the 

HOLD

 button 

momentarily to activate or to exit the hold feature. 
 

MAX 

 

The max feature compares and displays the measured maximum value as fast as 25ms 
in a single range, and with automatic up range capability. Press the 

MAX 

 button for 1 

second or more to activate or to exit the max feature in the voltage or current functions. 
 

Sleep Mode 

The meter will enter a low power consumption sleep mode automatically to extend 
battery life after approximately 30 minutes of no rotary-switch or push button operations. 
To wake up the meter from sleep mode, press any buttons momentarily or turn the 
rotary-switch to an adjacent position. Always set the rotary-switch to the OFF position 
manually when the meter is not in use. 
 

13

 

Содержание MD 9020

Страница 1: ...METREL MD 9020 Electrical Electronic Bench and Field Service Digital Multimeter with Temperature MD 9020 User Manual Bedienungsanleitung Version 1 1 Code no 20 751 286...

Страница 2: ...t Unit 1 Hopton House Ripley Drive Normanton Industrial Estate Normanton West Yorkshire WF6 1QT Great Britain E mail info metrel co uk Internet http www metrel co uk 2007 METREL Mark on your equipment...

Страница 3: ...English 1 Safety 4 2 Cenelec Directives 6 3 Product Description 7 4 Operation 8 5 Maintenance 14 6 Specification 16 LIMITED WARRANTY 20 Deutsch 1 Sicherheit 21 2 Cenelec Richtlinien 23 3 Produktbesch...

Страница 4: ...OVERVOLTAGE CATEGORY III Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations Note Examples include switches in the fixed installation and some equipment for industrial use with...

Страница 5: ...Disconnect the test leads from the test points before changing functions Always set the instrument to the highest range and work downward for an unknown value when using manual ranging mode INTERNATI...

Страница 6: ...MD 9020 Electrical Electronic DMM Cenelec Directives 6 2 Cenelec Directives The instruments conform to CENELEC Low voltage directive 73 23 EEC and Electromagnetic compatibility directive 89 336 EEC...

Страница 7: ...unction availability to each model 3 3 4 digits 4000 counts LCD display Push buttons for special functions features Selector to turn the Power On or Off and select a function Input Jack for 10A 20A fo...

Страница 8: ...pedance for least current drain in measuring small signals and can cope better with most commercially available voltage output transducers and adapters The non zero display reading is normal when the...

Страница 9: ...ient for checking wiring connections and operation of switches A continuous beep tone indicates a complete wire CAUTION Using Resistance Continuity Diode or Capacitance function in a live circuit will...

Страница 10: ...biased across the diode The digital display shows OL if the diode is good Any other readings indicate the diode is resistive or shorted defective Defaults at Press SELECT button momentarily 3 times to...

Страница 11: ...se to earth voltage To avoid exceeding the voltage rating of the protection fuse s accidentally always consider the phase to phase voltage as the working voltage for the protection fuse s Beep Jack In...

Страница 12: ...can also use a plug adapter AMD 9024 Optional purchase with banana pins to type K socket to adapt other type K standard mini plug temperature probes Relative zero mode Relative zero mode allows the us...

Страница 13: ...omentarily to activate or to exit the hold feature MAX The max feature compares and displays the measured maximum value as fast as 25ms in a single range and with automatic up range capability Press t...

Страница 14: ...or abnormal conditions of operation the series fusible resistors will be blown off become high impedance like fuses to protect the user and the instrument Most measuring functions through this termin...

Страница 15: ...door Loosen the 4 screws from the case bottom Lift the end of the case bottom nearest the input jacks until it unsnaps from the case top Replace the blown fuse s and or the battery Replace the case b...

Страница 16: ...y double insulation per UL3111 1 1994 CSA C22 2 No 1010 1 92 EN61010 1 1995 and IEC61010 1 1995 to CAT II 1000V CAT III 600V Standard CE version series Terminals to COM ratings V Category II 1000 Volt...

Страница 17: ...Features 25ms Max Hold Data Hold Relative zero mode Beep jack input warning Back lighted display Accessories Test leads pair batteries installed user s manual Optional Accessories AMD 9023 Banana plu...

Страница 18: ...0 03V A 10 00A 1 8 4d 0 03V A 10A continuous 20A for 30 second max with 5 minutes cool down interval Diode Tester Open Circuit Voltage Test Current Typical 1 6 VDC 0 25mA Type K Temperature MD 9020 RA...

Страница 19: ...imately 2 4V Hz Frequency RANGE Accuracy 50 00Hz 500 0Hz 5 000kHz 50 00kHz 500 0kHz 1 000MHz 0 5 4d Additional 5 000Hz range accuracy sensitivity are not specified Accuracy is specified at 20VAC rms I...

Страница 20: ...the specifications of the equipment or the user manual Damage after a drop a shock or flooding The contents of this manual must not be reproduced in any form whatsoever without the consent of the manu...

Страница 21: ...pannung Serie CE und UL Version mit verst rktem Schutz Nennwerte der Anschl sse nach COM V Kategorie II 1000 V Wechsel und Gleichspannung sowie Kategorie III 600 V Wechsel und Gleichspannung A mA A Ka...

Страница 22: ...ie keinen Strom der den Nennstrom der Schutzsicherung bersteigt Versuchen Sie keine Strommessung an einem Kreis dessen Leerlaufspannung ber der Nennspannung der Schutzsicherung liegt Die vermutete Lee...

Страница 23: ...0 Digitalmultimeter Cenelec Richtlinien 23 2 Cenelec Richtlinien Die Instrumente entsprechen der CENELEC Niederspannungsrichtlinie 73 23 EWG und der Richtlinie Elektromagnetische Vertr glichkeit 89 33...

Страница 24: ...e Funktionen f r jedes Modell zur Verf gung stehen 3 3 4 stelliges LCD Display 4000 Z hler Tasten f r Sonderfunktionen Wahlschalter zum EIN AUS Schalten und W hlen einer Funktion Eingangsbuchse f r di...

Страница 25: ...000 M zugunsten geringster Stromaufnahme bei der Messung kleiner Signale entwickelt und kann besser mit den meisten im Handel erh ltlichen Messaufnehmern Adaptern mit Spannungsausgang klarkommen Die v...

Страница 26: ...ngen und der Funktion von Schaltern dient Ein Dauer Piepton gibt einen geschlossenen Stromkreis an VORSICHT Die Verwendung der Widerstands Durchgangs Dioden oder Kapazit tsfunktion in einem unter Span...

Страница 27: ...der Pr fleitungen ber der Diode um Das Digitaldisplay zeigt OL wenn die Diode gut ist Jede andere Anzeige weist darauf hin dass die Diode einen endlichen Widerstand hat oder kurzgeschlossen ist defek...

Страница 28: ...e betr chtlich h her ist als die Phasenspannung gegen Erde Um ein versehentliches berschreiten der Nennspannung der Schutzsicherung en zu vermeiden betrachten Sie immer die Spannung zwischen den Phase...

Страница 29: ...AMD9024 optionaler Zukauf mit Bananensteckern f r die Typ K Fassung verwenden um andere Temperaturf hler Typ K mit Standard Miniaturstecker zu adaptieren Modus relativer Nullpunkt Der Modus relativer...

Страница 30: ...ie kurz die Taste HOLD um die Haltefunktion zu aktivieren oder zu verlassen MAX Die M x a Funktion vergleicht den gemessenen Maximalwert innerhalb von 25 ms in einem einzelnen Bereich mit automatische...

Страница 31: ...durch nehmen eine hohe Impedanz an um den Anwender und das Instrument zu sch tzen Die meisten Messfunktionen ber diesen Anschluss sind dann unterbrochen Die Serien Sicherungswiderst nde und die Funken...

Страница 32: ...ngseing ngen an bis es sich vom Geh useoberteil l st durchgebrannte n Sicherung en und oder die Batterien Setzen Sie das Geh useunterteil wieder auf und achten Sie dabei darauf dass alle Dichtungen ri...

Страница 33: ...94 CSA C22 2 NO 1010 1 92 EN61010 1 1995 und IEC61010 1 1995 nach cat ii 1000 v und cat iii 600 v gesch tzt Standard CE version nennwerte der anschl sse nach com V kategorie ii 1000 v wechsel und glei...

Страница 34: ...k hinterleuchtetes Display Zubeh r Pr fleitungen Paar eingesetzte Batterien Bedienungsanleitung mit Garantiererkl rung Optionales Zubeh r 1 X Temperaturf hler Typ K mit Bananensteckern AMD9023 nur MD...

Страница 35: ...uernd 20 A ber max 30 Sekunden mit 5 Minuten Abk hlpause Wechselspannung BEREICH Genauigkeit 50Hz 500Hz 400 0 mV 4 0 5 Dig 4 000 V 40 00 V 400 0 V 1 5 5 Dig 1000 V 4 0 5 Dig CMRR 60 dB bei Gleichspann...

Страница 36: ...000 k 40 00 k 400 0 k 1 0 4 Dig 4 000 M 2 0 4 Dig 40 00 M Leerlaufspannung 0 4 VDC typisch Kapazit t BEREICH Genauigkeit 500 0 NF 5 000 F 50 00 F 500 0 F 3000 F 3 5 6 DIG Genauigkeit f r den zus tzli...

Страница 37: ...37 Eingangssignal Rechteck mit Tastverh ltnis 40 und 70 oder Sinuswelle Veff Empfindlichkeit 10 Hz 20 Hz Sinus 0 9 Veff 20 Hz 500 kHz 2 6 VS oder Sinus 1 9 Veff 500 kHz 1 MHz 4 2 VS oder Sinus 3 Veff...

Страница 38: ...ng Garantie ausgeschlossen sind Unsachgem er Gebrauch wie z B berlastung des Ger tes oder Verwendung von nicht zugelassenen Zubeh r Gewaltanwendung Besch digung durch Fremdeinwirkungen oder durch Frem...

Страница 39: ...39...