3  Power Supply and Electrical Specification

The QuasarMF is powered using 24 V DC which are connected at the front of the device
(X3). If you do not use a power supply supplied by metraTec, please make sure that your

own   PSU   provides   a   supply   voltage   of   high   quality.   If   possible,   use   a   PSU   with   high
precision/high speed linear regulator. If you use a switching PSU, please make sure that the

switching frequency is > 500 kHz.

Fig. 2: Power Connector Description (ref. Tab. 1)

Connector

Description

X3.1

GND

X3.2

24V DC

Tab. 1: 

Description of Power Connector

Operating Voltage

24 V DC

Power Consumption

1

, RF on

200 mA

Power Consumption

1

, RF off

80 mA

Power Consumption

1

, Sleep

20 mA

Voltage Inputs/Outputs

24 V

Tab. 2: Maximum Rating and Electrical Limits

1 Note: For Ethernet power consumption is increased by 250 mA.

Technical Documentation metraTec QuasarMF

                                                               Page 7 of 14

Содержание QuasarMF

Страница 1: ...Technical Documentation for metraTec QuasarMF RFID Reader Date December 2016 Version 1 5 Technical Documentation metraTec QuasarMF Page 1 of 14...

Страница 2: ...Intended Use 5 2 2 Technical Specification 5 2 3 Product Drawing 6 2 4 Scope of Delivery 6 2 5 Accessories 6 3 Power Supply and Electrical Specification 7 4 Communication 8 4 1 USB Driver Installatio...

Страница 3: ...tted This includes but is not limited to applications in nuclear facilities flight control systems life support systems or weapon systems The manufacturer denies the suitability of this device for suc...

Страница 4: ...ll further documents can be either found at the metraTec s product web page or are listed at http www metratec com Support Downloads Documentation Technical Documentation metraTec QuasarMF Page 4 of 1...

Страница 5: ...ication with RFID transponders according to ISO14443A and MIFARE protocols MIFARE Classic MIFARE Ultralight and MIFARE Plus 2 2 Technical Specification Operating Voltage 24 V DC Digital Inputs Outputs...

Страница 6: ...Demo Software are available via download from metraTec s website 2 5 Accessories The following accessories and modules are available to extend and evaluate the functionality of the QuasarMF HF RFID Mo...

Страница 7: ...egulator If you use a switching PSU please make sure that the switching frequency is 500 kHz Fig 2 Power Connector Description ref Tab 1 Connector Description X3 1 GND X3 2 24V DC Tab 1 Description of...

Страница 8: ...e basic option for connecting the QuasarMF with your host PC is using the USB connection every reader has 1 Connect the reader with a 24V DC power source as described before 2 Connect the reader with...

Страница 9: ...connect the antenna to the reader or multiplexer the devices are equipped with BNC jacks Necessary cables are therefore equipped with BNC plugs at both ends When connecting antennas with multiplexers...

Страница 10: ...rent of 250 mA per pin These can be used to directly power e g signal towers In total a maximum current of 1000 mA for all pins is allowed Outputs are equipped with internal overcurrent and overtemper...

Страница 11: ...Out 2 X2 6 Out 2 X2 7 Out 3 X2 8 Out 3 X2 9 Out 4 X2 10 Out 4 X2 11 In 1 X2 12 In 1 X2 13 In 2 X2 14 In 2 X2 15 GND X2 16 24 V DC Tab 3 Pin Description for digital IOs Note All Out X are connected to...

Страница 12: ...metals and other harmful substances as required by the RoHS Directive for many industries Hence our products are produced in the most environmentally friendly way possible 7 2 Declaration of Conformi...

Страница 13: ...10 2010 1 2 corrected use of label MIFARE CS 20 01 2014 1 3 correction of scope of delivery minor edits translation to English CS 30 10 2014 1 4 HF Antenna Integration Guide mentioned minor changes C...

Страница 14: ...other than internal purposes is only allowed with written permission by metraTec GmbH All trademarks are the property of their respective owners All rights reserved MIFARE Classic MIFARE Ultralight an...

Отзывы: