metraTec DMI15 Скачать руководство пользователя страница 16

8  Further Notes

8.1  Environmental

Electronic devices like the DMI15 are covered by the (German) ElektroG (electronic waste

law) as well as the European WEEE directive and as such may not be disposed of by way of
the normal household trash. Instead they have to be recycled properly. For you as our

customer this is no additional burden, however, as you can send the device back to us for
proper recycling. We assure you that the devices received back will be recycled properly

and in an environmentally friendly way. Our WEEE Registration ID is DE 56060482.

When selecting electronic components we additionally made sure that all components are

free of heavy metals and other harmful substances as required by the RoHS and REACH
Directives   for   many   industries.   Hence,   our   products   are   produced   in   the   most

environmentally friendly way possible. 

8.2  Declaration of Conformity

The DMI15 complies with all directives and regulations applicable in the European Union for

this kind of device. This especially includes all laws regarding use of spectrum and EMC. The
product   therefore   bears   the   CE   sign,   as   required   by   Directive   1999/5/EC   (Radio   &

Telecommunication Terminal Equipment Directive).

The product is currently not registered for use in the US or Canada. However, metraTec is
registered as a manufacturer of electronics at the FCC and IC. A certification of this product

is   therefore   possible,   if   required.   Please   ask   us   or   your   system   integrator   for   further
information.

Technical Documentation metraTec DMI15

                                                               Page 16 of 18

Содержание DMI15

Страница 1: ...Technical Documentation for metraTec DMI15 IoT HF RFID Reader Date December 2020 Version 1 0 Technical Documentation metraTec DMI15 Page 1 of 18...

Страница 2: ...ption 4 2 1 Intended Use 4 2 2 Technical Specification 5 2 3 Product Drawing 6 2 4 Scope of Delivery 7 2 5 Accessories 7 3 Power Supply Electrical Specification 8 4 Ethernet configuration 10 5 RFID An...

Страница 3: ...ies flight control systems life support systems or weapon systems The manufacturer denies the suitability of this device for such scenarios 1 3 Export Restrictions The DMI15 contains components that u...

Страница 4: ...T Engine software Highlights include a reading rate of up to 100 tag IDs sec and reading and writing data on tags without needing to address them individually This allows applications directly at conv...

Страница 5: ...olated 24V DC Inputs 2x 24 V DC Outputs 4x 24 V DC Out 1x Operating Frequency 13 56 MHz System Impedance 50 Ohm RF Output 250 mW Max Power Consumption 5W RF ON Operating Temperature 40 C to 85 C Dimen...

Страница 6: ...2 3 Product Drawing The DMI15 features 4 mounting holes on a 99 x 34 m grid The housing may be used as drilling template using a deep hole marker Technical Documentation metraTec DMI15 Page 6 of 18...

Страница 7: ...mo Software are available via download from metraTec s website http www metratec com Support Downloads 2 5 Accessories The following accessories and modules are available to extend and evaluate the fu...

Страница 8: ...r supply by the ethernet switch Alternatively the DMI15 can be powered using the 24V DC input which are available at the IO connector at the front of the device X2 If you do not use a power supply sup...

Страница 9: ...ng Voltage 24 V DC Power Consumption RF on 200 mA Power Consumption RF off 80 mA Power Consumption Sleep 20 mA Tab 2 Typical Current Consumption at 24V DC Technical Documentation metraTec DMI15 Page 9...

Страница 10: ...n The default IP setting is static 192 168 2 239 The interface configuration is available at this address using a web browser port 80 The serial ASCII data stream is available at port 10001 using a te...

Страница 11: ...he box The reading range can be up to 10cm for credit card size transponders The reading range will depend to a great extent on the size power consumption and quality of the transponder and needs to b...

Страница 12: ...per pin These can be used to directly power e g signal towers In total a maximum output current of 1000 mA for all pins is allowed when 24V DC power is supplied at the IO connector Otherwise the 13W P...

Страница 13: ...X2 16 are directly connected to X2 1 and X2 2 respectively These can be used as power supply outputs to supply e g sensors etc The power of these pins is limited by the power of the power supply used...

Страница 14: ...nternally connected to GND X2 8 Out 3 24V out internal high side switch 250mA max X2 9 Out 4 Return for Out4 internally connected to GND X2 10 Out 4 24V out internal high side switch 250mA max X2 11 I...

Страница 15: ...onnected to the DMI15 RF_On 2 amber Indicates that the RF field is turned on Tag_Detect 3 blue Indicates that a transponder inventory read or write operation was carried out successfully Link 4 amber...

Страница 16: ...als and other harmful substances as required by the RoHS and REACH Directives for many industries Hence our products are produced in the most environmentally friendly way possible 8 2 Declaration of C...

Страница 17: ...9 Version Control Version Change by Date 1 0 created TM 22 12 2020 Technical Documentation metraTec DMI15 Page 17 of 18...

Страница 18: ...Tec GmbH Reprint or reproduction of this documentation for other than internal purposes is only allowed with written permission by metraTec GmbH All trademarks are the property of their respective own...

Отзывы: