background image

USER MANUAL

05.10.2012

GLASS DOOR BOTTLE COOLERS

METOS MAXIGLASS NOVERTA

4146700,4146702, 4146704, 4146706, 4146708, 4146710, 4146712, 4146714, 4146716, 4146718, 4146720, 4146722, 4146724, 

4146726, 4146728, 4146730, 4146732, 4146734

Содержание MAXIGLASS NOVERTA

Страница 1: ...UAL 05 10 2012 GLASS DOOR BOTTLE COOLERS METOS MAXIGLASS NOVERTA 4146700 4146702 4146704 4146706 4146708 4146710 4146712 4146714 4146716 4146718 4146720 4146722 4146724 4146726 4146728 4146730 4146732...

Страница 2: ...ork 5 3 2 Installing the appliance 5 3 3 Fitting storage racks 5 3 4 Power supply 6 4 Using the appliance 7 4 1 Prior to use 7 4 2 Thermostat 7 4 2 1 Temperature setting 8 4 2 2 Manual defrost 8 4 2 3...

Страница 3: ...located Refrigerant can cause frost injury 1 2 During operation Only use this product for storing packed beverages Never use the product as a step Never store electrical appliances in the product Alwa...

Страница 4: ...1 Type plate Type Refrigerant type volume Power consumption Supply Rated current Climate classification Construction year Unit serial number A refrigerator is produced for optimal performance within c...

Страница 5: ...ance Place the appliance on a smooth surface 1 Place the product at his position 2 Make sure the product is standing level using a spirit level 3 Use the adjustable feet to level the product 4 To meet...

Страница 6: ...t Check for the correct power supply referred to the information on the type plate Ensure that the plug lead cannot be trapped or snagged If necessary the plug lead can be extended by a qualified elec...

Страница 7: ...Icons and functions On Compressor enabled Flashing Compressor delay enabled On Light output enabled On Fans output enabled Flashing Fans delay after defrosting On Measurement unit Flashing Programming...

Страница 8: ...the required parameter Press SET key to display its value Use UP or DOWN button to change the value Press SET to store the new value and move to the following parameter To exit press SET UP or wait f...

Страница 9: ...lly stop as soon as the temperature returns to normal value 4 3 Filling the cabinet This product is only to be used for the refrigeration of packed beverages Fill the cabinet during a period when it i...

Страница 10: ...be replaced immediately The machine must not be cleaned with a pressure washer either inside or out When the floor is washed water can splash up under the machine and damage the components These have...

Страница 11: ...ilation Clean magnetic seal replace if necessary Remove contents which may obstruct ventilation Defrost evaporator Thermostat or compressor is defect Fan evaporator or condenser is defect Contact your...

Страница 12: ...0 mm TYPE Power con sumption 173 W 173 W 173 W 173 W Volume 150 l 150 l 150 l 150 l Weight 58 kg 58 kg 58 kg 58 kg llumination 1 x 3 W 1 x 3 W 1 x 3 W 1 x 3 W Capacity tray 2x50 kg door 2x 50 kg door...

Страница 13: ...4 W Capacity tray 2x50 kg door 2x 50 kg door 2x 50 kg door 2x 50 kg door 2x 50 kg door Dims incl feet 900x506x900 910 mm Power supply 220 240V 50 Hz 1 Refrigerant R134a Cooling capacity 240W 5 08CC Th...

Страница 14: ...Power con sumption 316 W 316 W 316 W Volume 315 l 315 l 315 l Paino 103 kg 103 kg 103 kg llumination 1 x 4 W 1 x 4 W 1 x 4 W Capacity tray 2x50 kg door 2x50 kg door 2x 50 kg door Dims incl feet 1350x5...

Страница 15: ...chnet Bei jeder bertretung der oben genannten Richtlinie werden in allen L n dern Strafen auferlegt Gamko Holding BV befolgt im Allgemeinen die CECED Interpretation Europ isches Komitee von Hersteller...

Страница 16: ......

Отзывы: