2.  INSTALLATION

The following operations should be carried out before the ice maker is started:

•  Check hat the machine has not been damaged in any way during transporta-

tion.

•  Install the ice-maker in the intended position, making sure that it is perfectly 

level.

•  Make the water mains connections before connecting the electrical supply.

•  Connect the 3/4” feed tube supplied to the machine and to the cold drinking 

water feed line.

•  It is both practical and advisable for safety reasons to fit a water shut off valve, 

which is not supplied with the machine.

•  Attach a plastic hose with an internal diameter of 20mm and of suitable length 

(not more than one metre from the machine) to the drainage coupling on the 
machine, leading to the trap.

N.B.

When choosing where to install the machine, it is important to en-

sure that:

a) the room temperature doeas not drop below +5° and does 
not 43°C
b) the temperature of the water does not drop below +10°C and 
does not 30°C
c) the water feed pressure does not drop below 1 bar and does 
not exceed 5 ba. If the pressure exceeds 5 bar, fit a pressure 
reducer on the water supply unit serving the machine
d) the machine is well away from any sources of heat and in-
stalled in well-ventilated surroundings

- Make sure that the machine is installed in a position where the 

ventilation of the cooling unit cannot be obstructed (only air-cooled 

machine).

- Do not install the machine in dusty surroundings as the condenser 

in the cooling unit will become clogged very quickly (only air-cooled 

machines).

STOP