Rev. 01 - 11/2022

41

- Press the 

UP

 or 

DOWN

 key to select the 

duration

 of the blast

chilling cycle (the starting value displayed is the one set by de-
fault, parameter P19 or P20 respectively for positive blast chill-
ing

 cycle or negative blast chilling cycle).

+

The cycle time modification is not permanent (it does 

not change the default v

alues for parameters P19 and 

P20). When the cycle is next set, the default values set 
under parameters P19 and P20 will be shown again.

- Wai

t 5 seconds or press the 

SET

 key to confirm (the cycle time

display becomes fixed).

- Press 

the 

SET

 key to start the program. 

During the blast chill-

ing cycle the display shows the total cycle time (parameter P19
or P20 respectively for positive blast chilling cycle or negative
blast chilling cycle).

+

The time is displayed in the form of a decimal number, 
where the integer part represents the hours and the dec-
imal part represents the minutes (for example, “1.30” indi-
cates the time 90 minutes, i.e. 1 hour and 30 minutes).

At the end of the blast chilling cycle, the 

storage

 phase starts 

(signalled by a beep). The temperature measured by the cell 
probe is shown on the display. 

Storage phase characteristics:

 - a

fter a positive blast chilling cycle (parameter P19) 

 

room tem-

perature setting equal to the value set for parameter P17; 

 - after a negative blast chilling cycle (parameter P20) 

 

room

 

temperature setting equal to the value set for parameter P18.

8.

PROGRAM

SELECTION

PROGRAM

CONFIRMING

PROGRAM

STARTING

SEL

SET

SET

SELEZIONE

PROGRAMMA

CONFERMA

PROGRAMMA

SELEZIONE

TEMPO CICLO 

ABBATTIMENTO

CONFERMA

TEMPO CICLO 

ABBATTIMENTO

AVVIO

PROGRAMMA

UP

DOWN

SET

attendere

attendere

5 sec

5 sec

SEL

SET

SET

BLAST CHILLING

CYCLE TIME

SELECTION

BLAST CHILLING

CYCLE TIME

CONFIRMING

UP

DOWN

SET

wait

5 sec

wait

5 sec

Selecting and starting special functions 

The appliance is provided with special functions to manage the 
following blast chilling functions: 

-

manual defrost,

-

cell sterilization

 (optional, if provided by the blast chiller),

-

needle probe heating

 (optional, if provided by the blast chiller)

The storage phase starts automatically at the end of the special 
function and the buzzer will sound intermittently for the set time 
(this can be modified by the user under parameter P 0). 
To silence the buzzer in advance, press the DOWN key. 

Manual defrost 

Defrosting is normally performed by the User with the blast chill-
er door open (cell heating). Door opening or closure has no ef-
fect on the defrost process. 
To start defrosting press and hold the 

DOWN

 key for 4 seconds.

+

The defrost configuration and duration are determined 

by the parameters P 5, P 7, P11, which can be modified 
by the User. During the defrost, the display shows the 
“dEF” string.

Cell sterilization 

Sterilization can be enabled if the value of parameter P23 is equal 
to 1. To activate a sterilization cycle there must be no program or 
other special function in progress and the blast chiller door must 
be closed. 
To start the sterilization cycle hold down the 

UP

 key for 4 sec-

onds.

+

The sterilization cycle start and duration are determined 
by the parameters P 8, P24, P25, which can be modified 
by the User. During the sterilization cycle the display 
shows the “StE” string. 

In the case of a cell probe error “Er2”: 
-  before the sterilization cycle start, the sterilization cycle does

not start;

-  during the sterilization cycle, the sterilization cycle continues

normally.

If at start-up or during the sterilization cycle the cell temperature 
is lower than the reference value (parameter P25), the display will 
show the “cLd” string.a.

Needle probe heating 

Needle probe heating can be activated if the value of parameter 
P23 is equal to 2. Door opening or closure has no effect on needle 
probe heating. To activate needle probe heating there must be no 
program or other special function in progress.

To start needle probe heating hold down the 

UP

 key for 4 seconds.

+

The needle probe heating configuration is determined 
by the parameters P28 and P29, which can be modified 
by the User. During needle probe heating, the display 
shows the “Prb” string. 

Stopping and restarting a program or a 

special function 

During the execution of a program or a special function, press 
the 

SET

 key to stop it. 

If a program has been completed, press the 

SET

 key again to 

restart from the point in which it was interrupted.

+

If the restarted program is of the manual type, the cycle 
starts from the beginning for the set cycle time.

If a special function was not completed, it is not possible to re-
start from the point where it was interrupted.

Содержание 4040340

Страница 1: ...r Shock Freezer E PRO 4240338 4240339 4040340 4040341 4040342 4040343 4040344 4040345 4040346 4040347 Original instructions 3 C 18 C start stop set L1 L2 L3 RF50C00064 REV 02 11 2022 Installation and...

Страница 2: ...Rev 02 11 2022 2 INSTALLATION SECTION reserved to skilled and authorised technicians SAFETY INSTRUCTIONS 5 INSTALLATION 8 BLAST CHILLER TECHNICAL DATA 64...

Страница 3: ...all necessary information for the correct installation of the device operat ed by skilled personnel Read the instructions carefully before performing any operations as they provide essential indicatio...

Страница 4: ...in this appliance Before installation please check that the areas in which the machine will be in stalled are suitable for food preparation that the systems comply with the legal provi sions in force...

Страница 5: ...Rev 02 11 2022 8 OK EXPRESS MAX 200 cm A B C INSTALLATION Fig 2 Fig 3 Fig 4 Fig 5 Fig 1 Abb 4 Abb 1 Abb 2 Abb 3 Abb 5...

Страница 6: ...200 cm min 4 INSTALLATION Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 Abb 6 Abb 7 Abb 8 Abb 9 Abb 10 1 PH monofase single phase monophas einphasig monof sico scarico vano compartment drain compartiment vacuation S...

Страница 7: ...rovided spacers on the back of the device especially if the device is assembled on wheels Use supplied spacers and screws only Drawings on page 8 Product transport handling Warning markings are printe...

Страница 8: ...sensitivity 30 mA with adequate power that permits com plete cut off in over voltage category III conditions in order to protect the device against over voltages or short circuits For the sizing of th...

Страница 9: ...alternative format QR CODE QR CODE SCAN 1 2 PDF USER MANUAL WIRING DIAGRAMS Maximum storage values 60 C Maximum transport values 60 C Maximum values for the installation environment 43 C Do not stack...

Страница 10: ...logy in a single machine that allows you to perform different and complemen tary activities for best efficiency in the kitchen this way you ll be immediately operative without having to run any comple...

Страница 11: ...USER SECTION reserved to user SAFETY INSTRUCTIONS 24 INFORMATION 30 USE 38 MAINTENANCE 46 ALARMS 54...

Страница 12: ...or any other non food products Specifically Blast chillers 90 3 C 90 18 C suited to rapidly lower food temperature to keep senso ry properties unaltered The following instructions must be followed for...

Страница 13: ...ctly horizontal and flat Always lock the wheels with the specific stops RISKS DUE TO MOBILE ELEMENTS the only mo bile element is the fan which however does not constitute a risk since it is protected...

Страница 14: ...Rev 02 11 2022 30 OK Fig 11 Fig 12 Abb 11 Abb 12...

Страница 15: ...d to keep all the sensory properties of the food intact The chiller reduces the product temperature un til reaching 18 C at its core Subsequently the product must be stored in a freezer at a constant...

Страница 16: ...be temperature Fast decrease of the value and defrost activation Slow increase of the value and cell temperature display Fast increase of the value and load activation on the auxiliary output UV lamp...

Страница 17: ...an automatic program Fig 8 on page 18 pro ceed as described below Press the SEL key until the display shows the positive blast chilling cycle default 3 C P13 parameter or negative blast chilling cycle...

Страница 18: ...ilence the buzzer in advance press the DOWN key Manual defrost Defrosting is normally performed by the User with the blast chill er door open cell heating Door opening or closure has no ef fect on the...

Страница 19: ...Rev 02 11 2022 46 H2 O 1 4 3 2 Fig 13 Fig 14 Fig 15 Fig 16 Abb 13 Abb 14 Abb 15 Abb 16...

Страница 20: ...uthorities or Dealer to request the correct disposal method While awaiting dismantling and disposal the equip ment can be temporarily stored even outdoors provid ed the electrical refrigeration and pl...

Страница 21: ...ondenser probe error The auxiliary condenser probe is not connected properly Check the connection of the auxiliary probe to the EWBC1400 Auxiliary condenser probe failure Replace the auxiliary probe d...

Страница 22: ...e PB1 PB2 and PB3 error cyclic display in succession of Er1 Er3 Er1 Er2 Error of three probes excluding PB1 probe PB2 PB3 and PB4 error cyclic display in succession of Er2 40 Er3 40 Er4 40 Open door w...

Страница 23: ...To ensure that the appliance is in perfect use and safety con ditions we recommend you have it maintained and ser viced by an authorised service centre at least once a year Manufacturer data F R C Via...

Страница 24: ...e manufacturer s warranty on the equipment and its relative parts is for 1 year from the invoice date and consists in the free supply of parts which at its sole discretion are deemed to be defective a...

Страница 25: ...e provides important technical information this is essential in case of device maintenance or repairs we recom mend you do not remove damage or modify the plate EN Serial number plate details 1 Manufa...

Страница 26: ...10 15 Type of pans grilles GN2 3 GN1 1 GN1 1 GN1 1 GN1 1 Interasse min reggiteglie 40 40 70 70 70 Pan capacity t GN 1 1 EN1 H 20 mm n 10 10 18 step 80 80 35 35 36 5 H 40 mm n 6 6 12 step 80 80 52 5 52...

Страница 27: ...nd nd nd CF031 10 nd nd nd nd nd nd nd nd SB 050 RW 25 15 20 10 1 58 2 53 105 205 0 079 0 506 SB 050 RA 25 15 20 10 1 58 2 53 105 205 0 079 0 506 SB 050 RA R290 25 15 20 10 1 26 2 92 91 240 0 064 0 2...

Страница 28: ...ob tain the data required by directive 2006 42 EC Machine operating conditions The tests were conducted in the most severe conditions which correspond to the starting phase called PULL DOWN Materials...

Страница 29: ...Metos Oy Ab Ahjonkaarre FI 04220 Kerava Finland tel 358 204 3913 www metos com...

Отзывы: