Diode 

Turn the rotary selector to the 

GR

 /600 

 position. Diode test is the 

default function. The reading shows the approximate voltage drop across 
the test leads. Normal forward voltage drop (forward biased) for a good 
silicon diode is between 0.400 V to 0.900 V. A reading higher than that 
indicates a leaky diode (defective). A zero reading indicates a shorted diode 
(defective), and the meter will give a long beep as continuity warning. OL 
indicates an open diode (defective). Reverse the test leads connections 
(reverse biased) across the diode. The digital display shows OL if the diode 
is good. Any other readings indicate the diode is resistive or shorted 
(defective). 

600 

 

Press the SELECT button to select the lowest 600 

 range for lower 

resistance measurements. It is an extended range to complement the 
AutoTect

 resistance function. 

µ

A dc and 

µ

A ac 

Turn the rotary switch to the 

µ

A position, 

µ

A dc is the default function. 

There is no annunciator for dc. Press the SELECT button momentarily to 
select 

µ

A ac. The ac annunciator 

B

 appears.  

Product Maintenance 
Maintenance 

Do not attempt to repair this meter. It contains no user serviceable parts. 
Repair or servicing should only be performed by qualified personnel. 

Cleaning 

Periodically wipe the case with a damp cloth and mild detergent; do not use 
abrasives or solvents. If the meter is not to be used for periods of longer 
than 60 days, remove the battery and store it separately 

Содержание AM-PM55A

Страница 1: ...PM55 Automatic Precision Pocket Meter Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso PN 2153049 August 2004 2004 Meterman Test Tools All rights reserved Printed in Taiwan...

Страница 2: ...A LCD display B Rotary switch to select functions and to turn the power on or off C SELECT button to select alternate functions and turn the power off and on D Permanently attached red test lead for...

Страница 3: ...ements 4 AutoTect Mode 5 Continuity Audible With Symbolic Display 5 Electric Field EF Detection VolTect 6 Voltage 8 Resistance 8 Frequency 8 Capacitance 8 V dc V ac and Line Level Hz 8 Diode 9 600 9 A...

Страница 4: ...s and EN61010 1 2001 CAT II 600 V CAT III 300 V class 2 and pollution deg 2 This instrument is EN61010 1 certified for Installation Category II 600 V It may only be used to make measurements on energy...

Страница 5: ...e case Always measure current in series with the load NEVER ACROSS a voltage source Symbols Used in this Manual N Battery W Refer to the manual T Double insulated X Dangerous Voltage F Direct Current...

Страница 6: ...st lead for positive polarity and Black test lead for Ground reference unless otherwise specified AutoTect mode is the default function in Auto V position Press the SELECT button momentarily to select...

Страница 7: ...d ghost voltages or a hard connection Ghost voltages will be zeroed out by the low input impedance Overload Alert Feature When more than 600 V is present the meter displays OL with a warning beep tone...

Страница 8: ...cations later in this manual for a complete description of the bar graph indicators An antenna is located at the top left corner of the meter which detects electric field surrounding current carrying...

Страница 9: ...7 Note For Maximum sensitivity hold the meter away from the VolTect corner SELECT SELECT...

Страница 10: ...is ready This function is auto ranging Return to Auto Press the SELECT button 8 times to return to AutoTect test mode V dc V ac and Line Level Hz Turn the rotary switch to the V position to select com...

Страница 11: ...indicate the diode is resistive or shorted defective 600 Press the SELECT button to select the lowest 600 range for lower resistance measurements It is an extended range to complement the AutoTect res...

Страница 12: ...chnician Refer to the LIMITED WARRANTY section for obtaining warranty or repairing service Battery Replacement If the meter starts up with persistent resetting display or with low battery icon N turns...

Страница 13: ...WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY ARE HEREBY DISCLAIMED MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES ARISING...

Страница 14: ...and Canada should be sent to a Meterman Test Tools Service Center Call Meterman Test Tools or inquire at your point of purchase for current repair and replacement rates In USA In Canada Meterman Test...

Страница 15: ...ied Sensing Average sensing Overload Protection 600 V dc and V ac rms Low Battery Below approx 2 4 V Power Supply 3 V standard button battery x 1 IEC CR2032 ANSI NEDA 5004LC Power Consumption typical...

Страница 16: ...he measurement circuit Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference Accessories H PM prot...

Страница 17: ...l ACV AutoTect Threshold 1 5 V ac 50 Hz 60 Hz nominal Capacitance Range1 Accuracy2 100 0nF 1000nF 10 00 F 100 0 F 3 3 5 6 dgt 4 1 Accuracy below 50nF is not specified 2 Accuracies with film capacitor...

Страница 18: ...s for 6 000k 6 000M ranges 2 Add 40 dgt to specified accuracy while reading is below 20 of range Frequency Range1 Accuracy Specified At 10 00 Hz 30 00 kHz2 2 0 V Sine rms 10 00 Hz 999 9 Hz 0 5 4 dgt 6...

Страница 19: ...en Voltage 400 0 A 2 0 3 dgt 6 mV A 2000 A 1 5 3 dgt 6 mV A Voltect Typical Voltage Bar Graph Indication 20 V to 80 V 45 V to 125 V 70 V to 215 V 120 V to 285 V above 170 V Indication Bar graph segmen...

Страница 20: ...18 Audible Continuity Tester 600 Range Open Circuit Voltage 0 4 V dc typical Audible Threshold 175 125...

Отзывы: