In-Warranty Repairs and Replacement – All Countries 

Please read the warranty statement that follows, and check your battery 
before requesting repair. During the warranty period any defective test tool 
can be returned to your Meterman Test Tools distributor for an exchange 
for the same or like product. Please check the “Where to Buy” section on 
www.metermantesttools.com for a list of distributors near you. Additionally, 
in the United States and Canada In-Warranty repair and replacement units 
can also be sent to a Meterman Test Tools Service Center (see below for 
address).

 

Non-Warranty Repairs and Replacement – US and Canada 

Non-warranty repairs in the United States and Canada should be sent to a 
Meterman Test Tools Service Center. Call Meterman Test Tools or inquire at 
your point of purchase for current repair and replacement rates. 
 

In USA 

In Canada 

Meterman Test Tools 

Meterman Test Tools 

 

1420 75th Street SW 

400 Britannia Rd. E. Unit #1 

 

Everett, WA 98203 

Mississauga, ON L4Z 1X9 

 

Tel: 888-993-5853 

Tel: 905-890-7600 

 Fax: 

425-446-6390 Fax: 

905-890-6866 

Non-Warranty Repairs and Replacement – Europe 

European non-warranty units can be replaced by your Meterman Test Tools 
distributor for a nominal charge. Please check the “Where to Buy” section 
on www.metermantesttools.com for a list of distributors near you. 
 

European Correspondence Address*  

 

Meterman Test Tools Europe 

 

P.O. Box 1186 

 

5602 BD Eindhoven 

 The 

Netherlands 

*(Correspondence only – no repair or replacement available from this 
address. European customers please contact your distributor.) 

Содержание AM-PM55A

Страница 1: ...PM55 Automatic Precision Pocket Meter Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso PN 2153049 August 2004 2004 Meterman Test Tools All rights reserved Printed in Taiwan...

Страница 2: ...A LCD display B Rotary switch to select functions and to turn the power on or off C SELECT button to select alternate functions and turn the power off and on D Permanently attached red test lead for...

Страница 3: ...ements 4 AutoTect Mode 5 Continuity Audible With Symbolic Display 5 Electric Field EF Detection VolTect 6 Voltage 8 Resistance 8 Frequency 8 Capacitance 8 V dc V ac and Line Level Hz 8 Diode 9 600 9 A...

Страница 4: ...s and EN61010 1 2001 CAT II 600 V CAT III 300 V class 2 and pollution deg 2 This instrument is EN61010 1 certified for Installation Category II 600 V It may only be used to make measurements on energy...

Страница 5: ...e case Always measure current in series with the load NEVER ACROSS a voltage source Symbols Used in this Manual N Battery W Refer to the manual T Double insulated X Dangerous Voltage F Direct Current...

Страница 6: ...st lead for positive polarity and Black test lead for Ground reference unless otherwise specified AutoTect mode is the default function in Auto V position Press the SELECT button momentarily to select...

Страница 7: ...d ghost voltages or a hard connection Ghost voltages will be zeroed out by the low input impedance Overload Alert Feature When more than 600 V is present the meter displays OL with a warning beep tone...

Страница 8: ...cations later in this manual for a complete description of the bar graph indicators An antenna is located at the top left corner of the meter which detects electric field surrounding current carrying...

Страница 9: ...7 Note For Maximum sensitivity hold the meter away from the VolTect corner SELECT SELECT...

Страница 10: ...is ready This function is auto ranging Return to Auto Press the SELECT button 8 times to return to AutoTect test mode V dc V ac and Line Level Hz Turn the rotary switch to the V position to select com...

Страница 11: ...indicate the diode is resistive or shorted defective 600 Press the SELECT button to select the lowest 600 range for lower resistance measurements It is an extended range to complement the AutoTect res...

Страница 12: ...chnician Refer to the LIMITED WARRANTY section for obtaining warranty or repairing service Battery Replacement If the meter starts up with persistent resetting display or with low battery icon N turns...

Страница 13: ...WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY ARE HEREBY DISCLAIMED MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES ARISING...

Страница 14: ...and Canada should be sent to a Meterman Test Tools Service Center Call Meterman Test Tools or inquire at your point of purchase for current repair and replacement rates In USA In Canada Meterman Test...

Страница 15: ...ied Sensing Average sensing Overload Protection 600 V dc and V ac rms Low Battery Below approx 2 4 V Power Supply 3 V standard button battery x 1 IEC CR2032 ANSI NEDA 5004LC Power Consumption typical...

Страница 16: ...he measurement circuit Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference Accessories H PM prot...

Страница 17: ...l ACV AutoTect Threshold 1 5 V ac 50 Hz 60 Hz nominal Capacitance Range1 Accuracy2 100 0nF 1000nF 10 00 F 100 0 F 3 3 5 6 dgt 4 1 Accuracy below 50nF is not specified 2 Accuracies with film capacitor...

Страница 18: ...s for 6 000k 6 000M ranges 2 Add 40 dgt to specified accuracy while reading is below 20 of range Frequency Range1 Accuracy Specified At 10 00 Hz 30 00 kHz2 2 0 V Sine rms 10 00 Hz 999 9 Hz 0 5 4 dgt 6...

Страница 19: ...en Voltage 400 0 A 2 0 3 dgt 6 mV A 2000 A 1 5 3 dgt 6 mV A Voltect Typical Voltage Bar Graph Indication 20 V to 80 V 45 V to 125 V 70 V to 215 V 120 V to 285 V above 170 V Indication Bar graph segmen...

Страница 20: ...18 Audible Continuity Tester 600 Range Open Circuit Voltage 0 4 V dc typical Audible Threshold 175 125...

Отзывы: