The dispenser is designed and built to be relatively maintenance free.  To assure 
trouble free operation, the following recommendations should be followed: 

1.

 

Make certain air supply is clean and dry. 

2.

 

Avoid turning barrels upside down or laying barrel so that material may 
run through air line to internal components. 

3.

 

Avoid connecting the unit to excessive moisture or solvent saturation. 

4.

 

Avoid connecting air supply exceeding 100 psi (6.9 bar) for the DX-250 
and 15 psi (1.03 bar) for the DX-255. 

5.

 

Use only Amyl Alcohol to clean outside surface of the main housing. 

6.

 

Use only soft cloth to clean the LCD. 

 

9

 

SPARE PARTS  AND ACCESSORIES 

 

For DX-3xx/2xx spare parts and accessories information, please visit the DX-
3xx/2xx User Guide webpage at 

http://www.metcal.com

 

 

 

 

 

10

 

LIMITED WARRANTY 

 
Metcal warrants  this  product  to  the  original  purchaser  for  a  period  of  one  (1)  year 
from  date  of  purchase  to  be  free  from  material  and  workmanship  defects  but  not 
normal  wear-and-tear,  abuse  and  faulty  installation.   Defective  product  or 
subassembly  and  components  under  warranty  will  be  repaired  or  replaced 
(at Metcal's option) free of charge. Customer with defective product under warranty 
must contact the nearest Metcal office or distributor to secure a return authorization 
prior to shipping the product to the assigned Metcal authorized service center.  For 
nearest  Metcal  office  or  distributor  contact  information,  please  visit 
www.metcal.com.   Metcal  reserves  the  right  to  make  engineering  product  changes 
without notice. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

11

 

I/O Configuration and End of Cycle Switch 

 

8

 

 

During a dispense cycle, an open collector circuit closes and remains closed while 
the valve is dispensing

.

 Pin 3 and 4 can be as feedback signal to synchronize with 

other devices.  Power from an external source is allowed to pass through the circuit 
to operate a 5 to 24 VDC load.  Power consumption must not exceed 250 mA.  The 
load could be a relay, solenoid, counter, LED, or any device that will operate within 
a 5 to 24 VDC range and a maximum of 250 mA.

   

 

Note: 
 During the dispense cycle, pin 3 will be grounded. Please make sure the 
external device (your machine that controls the dispenser/controller) has the 
same ground as the DX-250/255 controller. 

 
 

 

 
 
 
 
 
 
 
 
 

 

 

 
 

 
 
 
 
 
 
          

 
 
 
 

Pin 7, 8, and 9 = Available 

 Chasis Ground 

To initiate a dispense cycle

 

with 

contact closure 

When low pressure alarm is triggered, Pin 4 is grounded (-) 
When low pressure alarm is turned off,  
Pin 4 is not connected (opened)  

End of Cycle Feedback 
During dispensing cycle, Pin 3 is grounded (-) 
End of dispensing cycle,  
Pin 3 is not connected (opened) 

To initiate a dispense cycle with voltage

 

Pin 1 (+) 

Pin 2 (-) 

Pin 3 

Pin 4 

Pin 5  

Pin 6  

Pin 5  

Содержание DX-250

Страница 1: ...pplications of its equipment Unintended uses may result form taking the following actions Making changes to equipment that has not been recommended in the User Guide Using incompatible or damaged replacement partsUsing unapproved accessories or auxiliary equipment 1 2 Safety Precautions Do not operate this unit in excess of maximum ratings settings Always wear appropriate personal protective cloth...

Страница 2: ...C to 50 C 32 F to 122 F Storage Temperature 10 C to 60 C 14 F to 140 F Max Relative Humidity 80 for temperature up to 31 C 87 8 F Decreasing linearly to 50 relative humility at 40 C 104 F Air Output DX 250 0 100 psi 0 6 9 bar DX 255 0 15 psi 0 1 03 bar Vacuum 406mm 16 of Hg Timer 0 020 60 000 seconds Cycle Mode PURGE TIMED Timing Repeat Tolerance 0 001 Cycle Rate 600 cycles min LCD 16 X 2 display ...

Страница 3: ... To Air Source 2 Air Filter Not included 3 Power Adapter 4 Foot Switch 6 6 3 Cycle Counter The cycle counter records the numbers of dispense cycle being activated Up to 65 535 cycles can be recorded This number is shown at the lower right hand corner of the LCD Press the Counter Reset button 3 to clear the counter 7 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTION LCD does not light No power inpu...

Страница 4: ...fice or distributor to secure a return authorization prior to shipping the product to the assigned Metcal authorized service center For nearest Metcal office or distributor contact information please visit www metcal com Metcal reserves the right to make engineering product changes without notice 11 I O Configuration and End of Cycle Switch 8 During a dispense cycle an open collector circuit close...

Отзывы: