Description of the device
MRA - Series | Version 1.07
7
5.3 Storage
Store the notching machine thoroughly cleaned in a dry,
clean and frost-free environment.
Apply protective oil to the tool to prevent it from rusting.
6
Description of the device
Illustrations in this operating manual serve the gene-
ral understanding and may deviate from the actual
design.
Fig. 3: Description of the device MRA 2
1 Release lever
2 Housings
3 Notch opening for 43 mm diameter pipes
4 Notching knives
5 Mounting hole
7
Set up
In order to achieve a good function of the notching ma-
chine and a long service life, the site should meet the
following criteria.
- The notching machine may only be set up and ope-
rated in dry and freezing conditions.
- The substrate must be suitable for the work. Pay
attention to carrying capacity and evenness of the
subsoil.
- Protruding parts, such as support tables, etc., are
to be secured if necessary by on-site measures so
that persons are not endangered.
- Provide enough space for operators and material
handling.
- Ensure adequate lighting (minimum value: 300 lux)
1
2
4
5
3
DANGER!
Before setting up the machine, check the load-bea-
ring capacity of the substrate. The installation space
must be able to bear the weight of the machine, the
workpieces and the processing pressure.
NOTE!
Clean the notching machine before first use
- For this purpose use conventional solvents, for. B.
Petroleum.
- No water, no nitrolic solvents or similar use!
After the notching machine has been cleaned, all
bare parts must be lightly oiled. For this only resin u.
use acid-free machine oil!
Tips and recommendations
For a secure footing, it is advisable to fasten the not-
ching machine on a firm, stable and level surface
through the holes in the machine base.