3.5 Shutting Down
1.
Release the Trigger on the Handle
(A)
to stop spraying.
2.
The Pistol will stop spraying but air will continue to pass through the Spray Head and
there will be voltage at the terminals and wire.
3.
The Voltmeter
(B)
will once again display the ‘BEFORE SPRAYING’ Voltage.
4.
Press the red STOP button on the Pistol
(C)
. After a short delay this will switch off the
Air and Power to the Pistol.
NB:
Pressing the STOP button before releasing the trigger on the pistol can result in
damage to the Spray Head due to wire overrun.
5.
Turn the Energiser Mains switch
(D)
to OFF.
6.
If not spraying for an extended period, turn off the power and air supplies to the
Energiser.
7.
Once the environment has been cleared, turn off the Dust Extraction System.
3.6 Remote Pendant
An optional Remote Pendant is available. When connected, the Remote Pendant allows
remote operation of the system when the pistol is mounted to a robot or manipulator. It
connects to the rear of the Energiser
– see below.
B
D
Remote Input
Содержание ARC150-2310D
Страница 1: ...Page 1 of 48 ssue 21 11 11 ...
Страница 14: ...Page 14 of 48 SECTION 2 THE EQUIPMENT 2 1 System Configurations ...
Страница 41: ...Page 41 of 48 SECTION 5 FAULT FINDING 5 1 Operational Troubleshooting ...
Страница 43: ...Page 43 of 48 SECTION 6 ILLUSTRATED PARTS LIST 6 1 Main Components 6 2 CG Spray Head ...
Страница 46: ...Page 46 of 48 SECTION 7 INFORMATION TABLES 7 1 Typical Performance Figures ...