36
f.
Use the Left/Right arrow
keys to toggle the Display
Enabled option between
Enabled/Disabled. This
will cause the display to
turn off while still
allowing the data logger
to make measurements
and transfer files. After
selecting the option, the
display will automatically
turn off while the green
LED remains on. Before using any of the unit’s functions, power
the unit off and on again.
b.
Transferring the Files with Display Disable
To transfer files with disabled display, the unit must be in file
transfer mode. To turn on file transfer mode, hold ‘MNU/ENT’
for 3 seconds. When the unit is in file transfer mode the red LED
will flash 2 times a second.
To exit file transfer mode, hold ‘MNU/ENT’ for 3 seconds again.
The red LED will stop flashing.
a.
Downloading active probe Data
To download the data of the active probe ID, enter file
transfer mode as mentioned above, insert a Data
storage device, then hold the DOWN arrow key for 3
seconds. The green LED will flash once per second
during the file transfer. When the green LED stops
flashing, the Data storage device can be removed.
b.
Downloading all probe Data
To download the data of all probe IDs, enter file transfer
mode, insert a Data storage device, then hold the UP
and DOWN arrow keys for 3 seconds. The green LED will
7) Unit ID Setting
8) Alarm Mins. Disable
9) Factory Reset
10) Display Enabled
11) Del File After
USB Transfer: No
12) Copy Del File: No
Содержание MS3600E
Страница 2: ......
Страница 4: ......
Страница 25: ...21 FLASH DRIVE FOUND Step 2 Checking DIR Copying Files Remaining 0 ...
Страница 37: ...33 These error messages may appear while attempting a USB transfer No FLASH DRIVE Step 2 USB NOT DETECTED ...
Страница 49: ...Appendix B CERTIFICATION DETAILS ...