13
C. Setup and Operation
MAIN MENU
The MS3600E allows you to measure metal loss and
corrosion rate. This section describes the functions that
display on the Main Menu:
The Start-Up display shows the data logger’s unit ID at the top
of the screen.
It also shows the recent probe data in probe life units with a
range of 0 to 65535, metal loss in mils, and corrosion rate in
mils per year.
Probe ID, probe type and probe life are also displayed at the
bottom of the screen. Current date and time are displayed in
the last line.
Press ‘MNU/ENT’ key on the keypad to display the menu
screen.
METAL SAMPLES
Unit ID: 0000000001
Data (PLU): 32075
Metal Loss: 4.89 mils
CR: 21.141685 mpy
PID: 9991
TYPE: WIRE
PL:10.00
04/01/20 14:30