The boiler should be placed on a heat insulating non-flammable base, which on each side of the boiler should
be larger than the base of the boiler by 2 cm. If the boiler is located in a cellar, it is recommended that it is
placed on a foundation of at least 5 cm. The strength of the foundation as well as the fire protection conditions
are key guidelines when placing the boiler in the right location, these include:
●
20 cm safety distance from flammable materials,
●
40 cm for flammable materials of flammability grade C3,
●
40 cm if flammability is not known.
Flammability of building masses and products
Building materials and products
A - Non-flammable
Sandstone, concrete, bricks, fireproof plaster, mortar,
ceramic tiles, granite
B - Hard to burn
Wood and cement boards, fibreglass, mineral
insulation
C1 - Hard to burn
Beech wood, oak wood, plywood
C2 - Medium flammability
Pine, larch and spruce cork, sawn wood planks, rubber
floor coverings
C3 - Readily combustible
Asphalt plywood, celluloid, polyurethane, polystyrene,
polyethylene, plastic, PVC