Metabo KFM 18 LTX 3 RF Скачать руководство пользователя страница 9

ENGLISH

en

9

Switching on: 

Push the sliding switch (4) forward. 

For continuous activation, now tilt downwards until 

it engages.

Switching off: 

Press the rear end of the slide 

switch (4) and release it.

7.2 Setting speed

The speed can be preset via the thumb-wheel (6) 

and is infinitely variable. 
Positions 1-6 correspond approximately to the 

following no-load speeds:
1.........4500 / min

4 ....... 9500 / min

2.........6200 / min

5 ....... 10800 / min

3.........8100 / min

6 ....... 11500 / min

The VC electronics make material-compatible work 

possible and an almost constant speed, even under 

load. 
Speed recommendations for different materials:
Aluminium, copper, brass ..............................4-6

Steel up to 400 N/mm2 ..................................4-6

Steel up to 600 N/mm2 ..................................3-5

Steel up to 900 N/mm2 ..................................2-4

Stainless steel................................................1-3
The best way to determine the ideal setting is 

through a practical trial.

7.3 Working Directions

1. Check indexable inserts (21). Change damaged 

or worn indexable inserts.

2. Set the chamfer height (see section 6.2).

3. Always hold the machine with both hands on the 

intended handles, take a secure stance and 

concentrate on the work.

4. First switch on, then place the machine with the 

support surface (18) onto the workpiece and 

only then put the tool close to the workpiece.

5. When cutting, always work against the run of the 

disc (see illustration). Otherwise there is the risk 

of kickback. Cut with moderate material feed 

adapted to the material to be processed or 

selected speed. If the selected speed is too low 

and / or if the material feed is too high, strong 

vibrations can be caused (at the machine). Do 

not tilt, apply excessive force or sway from side 

to side.

6. Guide the machine in such a way that the parallel 

guide (17) is in contact with the workpiece. If you 

work without parallel guide: Guide the machine 

in such a way that the ball-bearing stationary 

seal ring (20) is in contact with the workpiece.

7. To finish work: Remove the tool from the 

workpiece, switch off machine. Let motor come 

to a stop, put down machine.

8.1 Change indexable inserts

Regularly check the holder for the indexable inserts 

(23). Repair/replace damaged or worn holders for 

the indexable inserts.
Regularly check all indexable inserts (21). Change 

damaged or worn indexable inserts.

Remove the battery pack from the machine / 

pull the plug out of the socket before making 

any adjustments, changing tools, carrying out 

maintenance or cleaning.

Indexable inserts, holders for indexable 

inserts, workpiece and chips can be hot after 

work. Wear protective gloves.

Turn/replace blunt indexable inserts or inserts 

where the coating is worn in due time. Blunt 

indexable inserts increase the risk of the machine 

getting jammed and climb out.

Always turn or replace all indexable inserts.

Use only indexable inserts approved by 

Metabo. See the Accessories Section.

1. By turning the adjustment ring (14) to the stop, 

unscrew the holder for the indexable inserts (23) 

as much as possible - this provides good access 

to the indexable inserts.

2. Press in the spindle locking button (2) and turn 

the holder for the indexable inserts (14) by hand 

until the spindle locking button (2) engages. 

Keep the spindle locking button (2) pressed.

3. Unscrew the fastening screw (22) and remove 

the indexable insert (21).

4. Turn the indexable insert or, if all blades are 

blunt, replace the indexable inserts.

5. Fix again the indexable inserts (21) with a 

fastening screw (22). Torque: 5 Nm.

6. Turn the adjusting ring (14) in the opposite 

direction, so that the holder for the indexable 

inserts (23) is again in its normal work range. (So 

that the maximum permitted chamfer height is 

not exceeded, see chapter Technical 

Specifications).

8.2 Replace ball bearing stationary seal ring 

(only if required): 

Regularly check the ball bearing stationary seal ring 

(20) for smooth running. Replace defective ball 

bearing stationary seal ring. (order no.: 316093300)
1. Remove screw (19) and remove ball bearing 

stationary seal ring.

2. Put new ball bearing stationary seal ring (20) in 

place and add screw (19), tighten firmly.

8.3 Adjust scale (only if required): 

The graduated ring (13) comes properly set from 

the factory.
If indexable inserts are to be used for radii or if the 

settings should have been misaligned, the scale 

has to be adjusted as follows:

8. Maintenance

Содержание KFM 18 LTX 3 RF

Страница 1: ...en Operating Instructions 4 fr Mode d emploi 12 es Instrucciones de manejo 21 KFM 9 3 RF KFM 18 LTX 3 RF...

Страница 2: ...6 B A 11 9 10 8 7 6 3 4 5 20 21 22 12 13 14 16 17 2 15 1 2 19 18 2...

Страница 3: ...8 n min 1 rpm 7000 11500 P1 W 900 P2 W 470 I120V A 8 0 hmax in mm 5 32 4 5 32 4 rmax in mm 1 8 3 1 8 3 a 45 45 m lbs kg 6 4 2 9 5 5 2 5 ah Kh m s2 0 94 1 5 0 7 1 5 LpA KpA dB A 84 3 87 3 LWA KWA dB A...

Страница 4: ...pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock e When operating a power tool outdoors use...

Страница 5: ...ower tool it does not assure safe operation b Do not use damaged power tools Before use check the indexable inserts for chipping cracks or signs of severe wear and tear If a power tool or accessory is...

Страница 6: ...ve and shock the operator Keep work area clean and well lit Cluttered or dark areas invite accidents WARNING Always wear protective goggles Wear ear protectors Wear a suitable dust protection mask Wea...

Страница 7: ...tery packs If battery fluid leaks out and comes into contact with your skin rinse immediately with plenty of water If battery fluid leaks out and comes into contact with your eyes wash them with clean...

Страница 8: ...ith the correct settings from the factory However should they be adjusted see chapter 8 3 6 2 Set chamfer height Read the set chamfer height at the graduated scale 13 1 Read the set chamfer height at...

Страница 9: ...for the indexable inserts 23 Repair replace damaged or worn holders for the indexable inserts Regularly check all indexable inserts 21 Change damaged or worn indexable inserts Remove the battery pack...

Страница 10: ...es The temperature is too high Run the machine in idling until the electronics signal indicator switches off The electronic signal display 8 flashes and the machine does not start The restart protecti...

Страница 11: ...res based on the adjusted estimates Vibration total value vector sum of three directions determined in accordance with EN 60745 ah SG Vibration emission value Kh SG Uncertainty vibration Typical A eff...

Страница 12: ......

Отзывы: