The optimum pump capacity is achieved by 

selecting the largest discharge line diameter.

4.2

Fixing the float switch cable

How the float switch cable is fixed to the 

device depends on the particular device 

model. If necessary, insert the float switch 

cable in the cable clip of the handle.

The following illustration shows the fixed float 

switch cable.

A

Caution! 

The float switch cable may be damaged. 

Never pull on the float switch cable to change 

its position in the cable holder!

4.3

Installation instructions

For the float switch to function properly, it 

must be able to move freely. 

Space requirement for DP 18-5 SA, DP 28-

10 S Inox: approx. 60 cm x 60 cm 

Space requirement for SP 24-46 SG, SP 

28-50 S Inox: approx. 70 cm x 70 cm.

Submerge the pump to no more than the 

maximum immersion depth specified in the 

technical data. 

Install the pump such that the suction inlets 

cannot be blocked by foreign objects. If 

necessary place the pump on a support 

surface. 

Ensure sufficient upright stability.

B

Risk of electric shock from severed 

cables! 

Do not lift or transport the pump by the cables 

or the discharge hose! The cables and the 

discharge hose are not designed to withstand 

the tensile stress produced by the weight of 

the pump.

4.4

Installing the pump

1. Submerge pump at a slight angle to avoid 

creating an air cushion on the underside, 

which would prevent priming. Once the 

pump is submerged, it can be placed up-

right.

2. Lower pump to the bottom of the fluid con-

tainer.

Use a strong rope fastened to the lifting 

eye to lower the pump. 

The pump can also be operated when sus-

pended by a rope.

3. Before operating the pump again, ensure 

that the pump line has been completely 

emptied. 

5.1

Switching ON and OFF

After you have connected the pump to the 

mains, it will be switched on 

(9)

 and off 

(10)

 

automatically by the float switch. The point in 

time at which switching occurs depends on 

the water level.

 

Adjusting the ON and OFF times for the 

pump

The position of the float switch cable in the 

cable holder can be changed. The time inter-

val between pump switch-on and switch-off is 

thereby adjusted:

– 'Short' float switch cable: ON and OFF po-

sitions are close together. 

– 'Long' float switch cable: ON and OFF po-

sitions are far apart.

A

Caution! 

Attach the float cable so that the OFF posi-

tion is at least 150 mm above the base of the 

pump. The pump may run dry and thereby be 

damaged.

A

Caution! 

The float switch must always be able to move 

up and down to allow the pump to be 

switched on and off.

5.

Operation

O

N

OF

F

9

10

Содержание DP 18-5 SA

Страница 1: ...es Manual original 26 pt Manual original 32 sv Originalbruksanvisning 38 fi Alkuper inen k ytt opas 43 da Original brugsanvisning 48 el 53 ru 59 sl Originalna navodila za uporabo 65 et Kasutusjuhend 7...

Страница 2: ...DP 18 5 SA DP 28 10 S Inox SP 24 46 SG SP 28 50 S Inox 1 1 2 2 3 3 4 1 2 3 4 4 5 6 7 5 6 7 5 6 5 6 7 1 2 3 4 7 2...

Страница 3: ...ining purposes on construction sites in agriculture and in domestic homes and gar dens SP 24 46 SG and SP 28 50 S Inox are also intended for draining wastewater both in in dustrial and domestic enviro...

Страница 4: ...pow er cable Connect only to an earthed outlet that is properly installed earthed and tested Mains voltage and fuse protection must correspond to those stated in the Technical Specifica tions Always...

Страница 5: ...are not designed to withstand the tensile stress produced by the weight of the pump 4 4 Installing the pump 1 Submerge pump at a slight angle to avoid creating an air cushion on the underside which wo...

Страница 6: ...n should only be carried out by qualified specialists 6 1 Regular care Regular care is required for the pump to func tion perfectly at all times This also applies if the pump is not switched on for ex...

Страница 7: ...king air Ensure there is a sufficient water sup ply Foreign objects are present clean pump Manual mode has been set shallow water suctioning Hold pump at an angle when submerg ing Pump runs continuous...

Страница 8: ...0 m 12 17 9 12 bar 1 2 1 7 0 9 1 2 m 7 7 7 7 mm 5 10 46 50 C 35 35 50 35 35 50 IP 68 68 68 68 m 10 10 10 10 1 1 2 2 mm 416 465 412 537 kg 10 18 5 18 19 3 max Hmax max EN 60335 1 EN 60335 2 41 2006 95...

Отзывы: