21
English
ABOUT ERROR LAMP OF AC/DC ADAPTER
Table 7
Indications of the indicator lamp
Status
Power
Lamp
(GREEN)
Error lamp
(RED)
Indicates
Adapter
Before use
Blinks
Light o
ff
Plugged into power
source
Power on
Lights
Light o
ff
Tool can be used
Power
suspended
Blinks
Lights
Blinks
Lights for 0.5 seconds. Does not light
for 0.5 seconds. (o
ff
for 0.5 seconds)
Adapter cannot be used
due to high temperature.
(Can be used once the
adapter is cooled)
Lights for 0.1 seconds. Does not light
for 0.1 seconds. (o
ff
for 0.1 seconds)
Overload
Box
Power
suspended
Blinks
Lights for 0.5 seconds. Does not light
for 0.5 seconds. (o
ff
for 0.5 seconds)
Cannot be used because
the temperature in the box
is too high
(Can be used once the
box is cooled)
MAINTENANCE AND INSPECTION
WARNING
Be sure to turn o
ff
the switch and pull out the battery before doing any inspection or maintenance.
1. Inspecting the bit
Continued use of a dull or damaged bit will result in
reduced cutting e
ffi
ciency and may cause overloading
of the motor. Replace the bit with a new one as soon
as excessive abrasion is noted.
CAUTION
If a dull bit is used, reactive force is increased
during cutting operation. Avoid the use of the
dull bit without repair.
2. Inspecting the screws
Regularly inspect all screws and ensure that they are
fully tightened. Should any of the screws be loosened,
retighten them immediately.
WARNING
Using this router with loosened screws is
extremely dangerous.
3. Maintenance of the motor
The motor unit winding is the very “heart” of the power
tool. Exercise due care to ensure the winding does not
become damaged and/or wet with oil or water.
4. Check for Dust
Dust may be removed with a soft cloth or a cloth
dampened with soapy water.
Do not use bleach, chlorine, gasoline or thinner, for
they may damage the plastics.
00Book̲M3612DA̲NA.indb 21
00Book̲M3612DA̲NA.indb 21
2020/11/18 9:52:42
2020/11/18 9:52:42