![Meta System BLE42 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/meta-system/ble42/ble42_user-and-installation-manual_1775953009.webp)
Fig.2
INSTALL AN
ADDITIONAL
RELAY
HORN
ORIGINAL
HORN
CONTROL
OUT (1/2/3)
BLE42
Fig.3b
INSTALL AN
ADDITIONAL
25A RELAY
STARTER
MOTOR
IGNITION
KEY BLOCK
CUT ORIGINAL WIRE
OUT (1/2/3)
BLE42
CODED
RELAY
STANDARD
STARTER
IMMOBILIZER
BLE42
OUT (1/2/3)
C
NC
C
NC
BLUE
BROWN
BROWN
GREEN
GREEN
RED
BLACK
Fig.4
INSTALL ADDITIONAL
RELAY IF HORN
IS POWERED BY
IGNITION-ON
HORN
ORIGINAL
HORN
CONTROL
ORIGINAL
HORN
RELAY
OUT (1/2/3)
BLE42
Fig.5
Fig.6
NEGATIVE PULSE
COMMAND
NO COMMAND
25 SEC.
1 SEC.
1 SEC.
CLACSON
PILOTING
CLACSON
PILOTING
HAZARD BUTTON
PILOTING
Fig.3a
BLE42
STARTER AUTHORIZATION
LOCKING
ST
ARTER
A
UTHORIZ
A
TION LINE
+30/F
POSITIVE WITH A SLEEP
MODE FUNCTION
OUT (1/2/3)
Coded output Set-Up
Card depending Set-Up
Horn output Set-Up
Hazard button Set-Up
Card depending
Set-Up
Horn output Set-Up
RELAY 1
RELAY 2
8. FUNCTIONS OF PROGRAMMABLE OUTPUTS OF BLE42 MODULE
The
BLE42 Module
has three programmable outputs able to provide different functions, below the list of the possible
options:
1. If it has been selected coded output when the
BLE42 Module
has a complete arming the external coded relays
actives opening their contacts, the contacts will be restored only after received the coded unlock command coming
from the
BLE42 Module
(Fig.2).
2. If it has been selected the output depending from the
ID-TAG Card B9.5
presence, with
BLE42 Module
activated
this output will be activate every time the
ID-TAG Card B9.5
will be out of its transmission range. With this output
it is possible pilot an external relay avoiding the car starting when the ignition key is ON or the +30 “sleep” passes to
active (Fig.3a/3b).
3. If it has been selected as a horn output when
BLE42 Module
is armed this output will be activate a 25 sec ON/OFF
cycle every time ignition key will turn ON ; the alarm cycle will start 10 sec after turning on the ignition key, turning
off the ignition key during the alarm cycle it doesn’t stop and will be completed. If the ignition key stay ON more of 25
sec the alarm cycles will be repeated for max 10 times with a 5 sec pause between the cycles (Fig.4/5).
4. If it has been selected as a Hazard button output when BLE42 Module is armed this output will be activate a 25 sec of
turning indicators cycle when ignition key will turn ON; the turning indicators activation will start 10 sec after turning
on the ignition key and the activation signal it is shown in Fig.6.
9
Содержание BLE42
Страница 11: ...11...