Meta System BLE42 Скачать руководство пользователя страница 8

FAST FLASHING LED

(1 flash every 1 sec)

Attempt of engine starting with armed

system and IGNITION KEY ON

sLOW FLASHING LED

(1 flash every 5 sec) 

System armed and instrument

IGNITION KEY OFF

LED ON

System ready to be disarmed

by turning on the ignition key

5. DESCRIPTION OF THE BLE42 IMMOBILIZER MODULE

The 

BLE42 module

 was designed for use inside the passenger compartment and executes an automatic ignition immo-

bilization after turning off the instrument panel if the 

ID-TAG Card B9.5

 is not present.

The module includes an internal immobilizer relay (C-NC) that’s activates only if turning on the instrument panel and it 
not recognize its 

ID-TAG Card B9.5

.

In addition of the internal relay are available 3 programmable outputs that allow to execute these following features:

1. Driving a coded external relays (Coded output Set-up).

2. Driving an external relay to perform a starter immobilization depending from absence of its 

ID-TAG Card B9.5

 

(Card depending Set-up).

3. Drive the clacson (Horn output Set-up).

4. Drive the Hazard push button to activate the turning indicators (Hazard button Set-up).

Included in the paragraphs of this manual are described a different options to use the module and some details 
useful to use it.

6. BLE42 IMMOBILIZER MODULE OPERATIONS

ACTIVATION OF STARTER IMMOBILIZER

After turning OFF the instrument panel the 

BLE42 module

 goes in pre-arming status, the LED goes ON; complete arming 

happen only 50 sec after complete absence of its 

ID-TAG Card B9.5

 in the module receiving area and the complete 

arming status is shows by a slow flashing LED (1 flash every 5 sec).

Note: 

Turning On the instrument during the pre-arming status the 

BLE42 module

 disarms and the LED goes Off.

PRESENCE OF ID-TAG CARD B9.5 IN THE MODULE RECEIVING AREA AND IGNITION KEY OFF

When the vehicle ignition Key is OFF the presence of the unlock device (

ID-TAG Card B9.5

) it’s always indicated by the 

LED ON fix, in this condition the immobilizer it’s ready to be completely unlocked turning ON the vehicle ignition Key.

DEACTIVATION OF STARTER IMMOBILIZER

After turning ON the instrument panel the 

BLE42 module

 disarms if its 

ID-TAG Card B9.5

 it is present and the LED goes 

Off. If the 

ID-TAG Card B9.5

 was lost or in case of flat battery it is possible disarm the 

BLE42 module

 introducing the 

Override PIN CODE, on the sticker supplied with product you can find the factory PIN CODE (see Fig.1) and it is customi-
zable by 

PRG007 programmer

.

LED OFF

System disarmed

and IGNITION KEY ON

lED EMIT 2 CLOSE FLASHES

Warning of id-tag card

low battery and IGNITION KEY ON

lED ON FOR FIRST 5 SEC. TURNING 

IGNITION KEY ON

SERVICE MODE enabled

7. BLE42 MODULE LED STATUS

The status LED permit to have indications about the protection system and in the following table are present the mea-
nings of flashes indications:

8

Содержание BLE42

Страница 1: ...nel caso si voglia abbinare al prodotto un ulteriore SmartPhone Password 5040351901 AVVERTENZE DI SICUREZZA I simboli grafici posti sull apparecchiatura indicano di attenersi alle specifiche informazi...

Страница 2: ...vo programmazione 2010337600 Per la selezione delle varie funzioni di prodotto utilizzare esclusivamente il programmatore PRG007 V3 L aggiornamento software del programmatore PRG007 V3 e le informazio...

Страница 3: ...ma della completa attivazione si accende il quadro strumenti il modulo si disinserisce e il LED si spegne RILEVAMENTO DEL PROPRIO DISPOSITIVO DI SBLOCCO CON QUADRO STRUMENTI SPENTO Con il quadro strum...

Страница 4: ...armati e aprono i loro contatti ripristinandoli solo alla successiva ricezione del comando di sblocco ricevuto dal modulo BLE42 Fig 2 2 In caso sia stata selezionata l uscita in conseguenza della pres...

Страница 5: ...ramite Override rimane disattivo fino a che non lo si riattiva volontariamente Con quadro strumenti OFF tenere premuto il pulsante per 10 sec fino all accensione del LED poi rilasciare il pulsante e p...

Страница 6: ...n order to use it if you have to pair another SmartPhone to the same product Password SAFETY WARNINGS The graphic symbols placed on the equipment indicate that the specific information in this manual...

Страница 7: ...3 and the programming cable 2010337600 Use only the PRG007 Programmer V3 to select the various functions of the product Software updates for the PRG007 Programmer V3 and information about the programm...

Страница 8: ...turning OFF the instrument panel the BLE42 module goes in pre arming status the LED goes ON complete arming happen only 50 sec after complete absence of its ID TAG Card B9 5 in the module receiving ar...

Страница 9: ...relays actives opening their contacts the contacts will be restored only after received the coded unlock command coming from the BLE42 Module Fig 2 2 If it has been selected the output depending from...

Страница 10: ...e code the system stay disarmed until the voluntary reactivation 10 2 REACTIVATION OF THE IMMOBILISER PROTECTION To reactivate the system follow the steps below With ignition key OFF press hold the LE...

Страница 11: ...11...

Страница 12: ...pliance with Radio Equipment Directive 2014 53 EU Frequency Bands in which the radio equipment operates 2402 0 MHz 2480 0 MHz 10mW e i r p Certificate Holder s Address Meta System S p A Via Galimberti...

Отзывы: